A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Samsung UCC2400C, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Samsung UCC2400C one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Samsung UCC2400C. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Samsung UCC2400C should contain:
- informations concerning technical data of Samsung UCC2400C
- name of the manufacturer and a year of construction of the Samsung UCC2400C item
- rules of operation, control and maintenance of the Samsung UCC2400C item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Samsung UCC2400C alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Samsung UCC2400C, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Samsung service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Samsung UCC2400C.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Samsung UCC2400C item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
ENGLISH Cassette-type Air Conditioner (Cool) Aire acondicionador T ipo Casete (Refrigeración) Climatiseur de type Cassette (Refroidissement) ES F DB68-02173A( 2 ) OWNER’S INSTRUCTIONS & INST ALLA TION MANUAL MANUAL DE INSTRUCCIONES & MANUAL DE INST ALACIÓN MANUEL D’UTILISA TION & MANUEL D’INST ALLA TION ACC2400C ACC2800C Indoor [...]
-
Page 2
Before Starting The wired remote controller , wireless remote controller and Centralized controller of the air conditioner are optional accessories. And your Owner’ s Instructions is for all of them. So that before using this instruction, ensure your option(s). E- 2 Safety Precautions ◆ If the power supply cord of this air conditioner is damage[...]
-
Page 3
Contents ◆ P REP ARING YOUR AIR CONDITIONER ■ Before Starting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 ■ Safety Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 ■ View of the Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 ■ Wired Remo[...]
-
Page 4
View of the Unit The figures are shown in this instruction may differ from yours depending on the model. Air flow blades(outlet) Refer to page 9 Air inlet Air filter(under the grille) Indoor Unit E- 4[...]
-
Page 5
Air inlet(Rear) Air outlet Connection valve Outdoor Unit E- 5 ENGLISH[...]
-
Page 6
Wired Remote Controller-Buttons and Display The wired remote controller is an optional accessory . - T est button is for your installation specialist. Y ou must NOT press it. - After cleaning the air filter , press the filter reset button. Then the wired remote controller will display the FIL TER SIGN indicator when the time to clean the air filter[...]
-
Page 7
Wireless Remote Controller-Buttons and Display The wireless remote controller is an optional accessory . After cleaning the air filter , press the filter reset button. N N N N o o o o t t t t e e e e Operating mode Mode selection button Filter Reset button Swing button On Timer button Off T imer button On/Off & Timer Set/Cancel button Fan speed[...]
-
Page 8
The centralized controller is installed on the wall. Centralized Controller The centralized controller is an optional accessory . Operating lamp All On button All Off button On/Off indicators On/Off buttons Index Operating lamp comes on when at least one air conditioner connected to the centralized controller is operating. N N N N o o o o t t t t e[...]
-
Page 9
The Indicators on the Unit (For Wireless Remote Controller Only) The receiver & display unit is an optional accessory for the wireless remote controller . T imer indicator On/Off button On/Off indicator Filter Sign indicator Remote control sensor E- 9 ENGLISH[...]
-
Page 10
G etting Start Y ou have just purchased a cassette type air conditioner and it has been installed by your installation specialist. Y our Owner’ s Instructions contain much valuable information on using your air conditioner . Please take the time to read them as they will help you take full advantage of the unit’ s features. The booklet is organ[...]
-
Page 11
Inserting the Wireless Remote Controller Batteries Push the battery cover on the rear of the remote controller with your thumb in the direction of the arrow and remove it. Insert the two batteries, taking care to respect the polarities : ◆ + on the battery with + on the remote controller . ◆ - on the battery with - on the remote controller . 1 [...]
-
Page 12
This chapter indicates how to operate and program your air conditioner with the wired remote controller . The wired remote controller is an optional accessory . U U U U s s s s i i i i n n n n g g g g W W W W i i i i r r r r e e e e d d d d R R R R e e e e m m m m o o o o t t t t e e e e C C C C o o o o n n n n t t t t r r r r o o o o l l l l l l l[...]
-
Page 13
In the Automatic mode, the room temperature and the fan speed are controlled automatically . 1 T o select the AUT O mode, press the Mode button until is displayed at the top of the wired remote controller . Result: : ◆ The air conditioner runs in AUT O mode. 2 Y ou can change modes at any time. If necessary , press (O N/ OFF) button. Result: : ?[...]
-
Page 14
Cooling Y our Room Y ou must select the COOL mode if you wish to adjust the : ◆ Cooling temperature ◆ Fan speed when cooling 1 If necessary , press (ON/OFF) button. Result: ◆ The On/Off indicator on the wired remote controller comes on. ◆ The air conditioner runs in the mode selected when ◆ the unit was last used. The air conditioner is f[...]
-
Page 15
Removing Excess Humidity E- 15 ENGLISH If the atmosphere in your room is very humid or damp, you can remove excess humidity without lowering the room temperature too much. 1 T o select the DR Y mode, press the Mode button until is displayed at the top of the wired remote controller . Result: ◆ The air conditioner runs in DR Y mode. 2 The air cond[...]
-
Page 16
Airing Y our Room E- 16 If the atmosphere in your room is stale, you can air it using the F AN feature. If necessary , press (ON/OFF) button. Result: ◆ The On/Off indicator on the wired remote controller comes on. ◆ The air conditioner runs in the mode selected when the unit was last used. 1 Select the fan speed by pressing the Fan button one o[...]
-
Page 17
Adjusting the Air Flow Direction Depending on the position of the indoor unit, you can adjust the position of the air flow blades, thus increasing the efficiency of the air conditioner . Press the Swing button. Result: The blades are moving between up and down. 1 T o stop the blades, press the Swing button again. T o set to the required position, p[...]
-
Page 18
Setting the On Timer The On T imer enables you to switch on the air conditioner automatically after a given period of time. Y ou can set the period of time from 30 minutes to 24 hours. If you want to turn on the air conditioner before the timer reaches the setting time, press the (O N / OFF) button. N N N N o o o o t t t t e e e e T o set the opera[...]
-
Page 19
Setting the Off Timer The Off T imer enables you to switch off the air conditioner automatically after a given period of time. Y ou can set the period of time from 30 minutes to 24 hours. T o cancel the Of f Timer , press the Of f Timer button one or more times until the timer setting disappears. 1 Press the (S et/Cancel) button. 2 T o set the oper[...]
-
Page 20
This chapter indicates how to operate and program your air conditioner with the wireless remote controller . The wireless remote controller is an optional accessory . U U U U s s s s i i i i n n n n g g g g W W W W i i i i r r r r e e e e l l l l e e e e s s s s s s s s R R R R e e e e m m m m o o o o t t t t e e e e C C C C o o o o n n n n t t t t[...]
-
Page 21
Selecting the Automatic Operation Mode In the Automatic mode, the room temperature and the fan speed are controlled automatically . 1 T o select the AUT O mode, press the Mode button until is displayed at the top of the wireless remote controller . Result: : ◆ The indoor unit beeps. ◆ The air conditioner runs in AUT O mode. 2 Y ou can change mo[...]
-
Page 22
Cooling Y our Room T o select the COOL mode, press the Mode button until is displayed at the top of the wireless remote controller . Result: ◆ The indoor unit beeps. ◆ The air conditioner runs in COOL mode. 2 Y ou can change modes at any time. T o adjust the temperature, press the T emperature buttons one or more times until the required temper[...]
-
Page 23
Removing Excess Humidity E- 23 ENGLISH T o select the DR Y mode, press the Mode button until is displayed at the top of the wireless remote controller . Result: ◆ The indoor unit beeps. ◆ The air conditioner runs in DR Y mode. 2 Y ou can change modes at any time. T o adjust the temperature, press the T emperature buttons one or more times until[...]
-
Page 24
Airing Y our Room If the atmosphere in your room is stale, you can air it using the F AN feature. T o control the direction of the air flow , refer to page 25. 4 Select the fan speed by pressing the Fan button one or more times until the intended value is displayed: 3 Low Medium High T o select the F AN mode, press the Mode button until i s display[...]
-
Page 25
Adjusting the Air Flow Direction Depending on the position of the indoor unit, you can adjust the position of the air flow blades, thus increasing the efficiency of the air conditioner . Press the Swing button. Result: ◆ The blades are moving between up and down. Result: ◆ The indoor unit beeps. 1 T o stop the blades, press the Swing button aga[...]
-
Page 26
Setting the On Timer The On T imer enables you to switch on the air conditioner automatically after a given period of time. Y ou can set the period of time from 30 minutes to 24 hours. T o set the operating time, press the On T imer button one or more times until the required time is displayed. Possible time is between 0.5 hour and 24 hour inclusiv[...]
-
Page 27
Setting the Off Timer The Off T imer enables you to switch off the air conditioner automatically after a given period of time. Y ou can set the period of time from 30 minutes to 24 hours. T o set the operating time, press the Off T imer button one or more times until the required time is displayed. Possible time is between 0.5 hour and 24 hour incl[...]
-
Page 28
Using the Centralized Controller The centralized controller is an optional accessory . Up to sixteen air conditioners can be turned on or off by connecting to the centralized controller . However , you cannot adjust the cooling temperature or set the timer with it. If you also have the wired remote controller , CENTRALIZED CONTROL is displayed at t[...]
-
Page 29
Operating Recommendations T emperature and Humidity Ranges Here are a few recommendations that you should follow when operating your air conditioner . T opic Recommendation If a power failure occurs while the air conditioner is operating, the unit will be switched off. When the power returns, the air conditioner restarts in the previous operation m[...]
-
Page 30
Cleaning Y our Air Conditioner T o get the best possible use out of your air conditioner , you must clean it regularly to remove the dust that accumulates on the air filter . Before cleaning your air conditioner , ensure that you have switched off the electric circuit breaker used for the unit. Open the front grille by pushing the tabs on the grill[...]
-
Page 31
Bio-Pure Filter Installation (Optional) Open the front grille by pulling the tabs on the grille. 2 Remove the front grille. 3-1 Remove the safety clips. 3-2 Open the front grille about 45 ° and pull it forward. 3 Pull out the air filter . 4 Locate the bio-pure filter on the center of air filter . 5 Secure the bio-pure filter with four screws. 6 Re[...]
-
Page 32
Solving Common Problems Before contacting the after -sales service, perform the following simple checks. They may save your time and expense of an unnecessary call. Explanation/Solution ◆ Check that the breaker used for the air conditioner is switched on. Problem The air conditioner does not operate at all ◆ Check that there are no obstacles be[...]
-
Page 33
Specifications E- 33 ENGLISH ✳ Standard rating conditions Cooling Indoor DB 80 26.7 °F °C WB 67 19.4 DB 95 35.0 WB 75 23.9 Outdoor MODEL INDOOR UNIT OUTDOOR UNIT ACC2400C ACC2800C Performance Ratings Capacity Cooling SEER Moisture Removal Air FLOW(Cooling, HIGH) Sound Rating-(In/Out) Power source Min.Ampacity Cooling W atts Connections Liquid L[...]
-
Page 34
(7 ) 200 7 8 (5 ) 145 11 16 (4 ) 126 15 16 (3 ) 90 9 16 (4 ) 110 5 16 (5 ) 146 3 4 (6 ) 156 1 8 (9 ) 246 11 16 (9 ) 230 1 16 (33 ) 840 1 16 (37 ) 950 3 8 (30 ) 766 3 16 (34 ) 880 5 8 (33 ) 840 1 16 (27 ) 699 1 2 (34 ) 880 5 8 (10 ) 260 1 4 25 (1) (11 ) 290 7 16 (Space of Suspension Bolts) (Outer Dimensions) (Cutting Dimension of Ceiling) (Dimension[...]
-
Page 35
Contents ◆ P REP ARING THE INST ALLA TION ■ Deciding on Where to Install the Air Conditioner . . . . . . . . . . . .36 ■ Air Conditioner and Accessories . . . . . . . . . . . . . . . . . . . . . . . .38 ◆ I NST ALLING THE INDOOR UNIT ■ Indoor Unit Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .39 ■ Purging t[...]
-
Page 36
Deciding on Where to Install the Air Conditioner When deciding on the location of the air conditioner with the owner , the following restrictions must be taken into account. General Do NOT install the air conditioner in a location where it will come into contact with the following elements: ◆ Combustible gases ◆ Saline air ◆ Machine oil ◆ S[...]
-
Page 37
Respect the clearances and maximum lengths indicated in the diagram below when installing the unit. “H” m/ft maximum ( ) 17 11 16 ( ) 20 13 16 ( ) 255 10 Space requirement when installing the indoor unit 300m m(12inch) minimum 3 0 0 m m (1 2 in ch ) m in im u m Liquid Refrigerant tube Gas Refrigerant tube Drain hose 350mm (14inch) minimum Model[...]
-
Page 38
Air Conditioner and Accessories The following accessories are supplied with the air conditioner . The quantities are indicated in parentheses. ◆ Refrigeration pipes and their insulating materials, power cables are not supplied. N N N N o o o o t t t t e e e e Basic Accessories Owner ’ s Instructions & Installation Manual (1) O W N E R &apos[...]
-
Page 39
Indoor Unit Installation () 17 11 16 () 20 13 16 1 Place the pattern sheet on the ceiling at the spot where you want to install the indoor unit. 2 Insert bolt anchors, use existing ceiling supports or construct a suitable support as shown in figure. 3 Install the suspension bolts depending on the ceiling type. 4 Screw eight nuts to the suspension b[...]
-
Page 40
Purging the Unit On delivery , the indoor unit is loaded with an inert nitrogen gas. All this gas must therefore be purged before connecting the assembly piping. T o purge the inert gas, proceed as follows. The indoor unit is powered from the outdoor unit via the connection cor d. Unscrew the caps at the end of each pipe. Result: All inert gas esca[...]
-
Page 41
Wiring Diagram Cable Specifications The following electrical characteristics must be respected. MODEL Power Sub switch Fuse Min. size of electric Wires from/to the indoor/outdoor unit Size of electric input wires 20 m(6 ft) or less 50 m(1 6 ft) or less Note 1Ø - 208-230V~, 60Hz ACC2800C ACC2400C 30A 30A 25A 25A H07RN-F , 4G, 1.0mm 2 H07RN-F , 3G, [...]
-
Page 42
Drain Hose Installation Care must be taken when installing the drain hose for the indoor unit to ensure that any condensate water is correctly drained outside. Insert the flexible hose to the drain tube outlet, if necessary . 1 Install the drain hose so that its length can be as short as possible. Internal diameter of the drain hose should be the s[...]
-
Page 43
◆ Y ou can check the drainage only when the air conditioner is turned on. N N N N o o o o t t t t e e e e ◆ If you do not pour water inside the water supply intake, water may spill from the indoor unit. N N N N o o o o t t t t e e e e T esting the drainage Y ou should test the drainage after completing the installation. Prepare a little water a[...]
-
Page 44
Connecting the Indoor Unit Assembly Piping There are two refrigerant pipes of differing diameters: ◆ A smaller one(6.35mm, 1/4 " ) for the liquid refrigerant ◆ A larger one(15.88mm, 5/8 " ) for the gas refrigerant ◆ The thickness of tube should not less than 1.0mm(1/16 ") . ◆ The inside of copper tube must be clean & has [...]
-
Page 45
Cutting/Flaring the Pipes Connect the pipe within 30m(100ft) and cutting pieces will not be gone into the pipe as being clean to pipe section. Make sure that you have the required tools available (pipe cutter , reamer , flaring tool and pipe holder). If you wish to shorten the pipes, cut it with a pipe cutter , taking care to ensure that the cut ed[...]
-
Page 46
Connecting the Cables to the Outdoor Unit T wo electric cables must be connected to the outdoor unit. ◆ The connection cord connecting the indoor unit to the outdoor unit ◆ The power cable connecting the auxiliary circuit breaker to the outdoor unit Remove the terminal board cover on the side of the outdoor unit. Connect the connection cord(1, [...]
-
Page 47
Checking Correct Grounding () 2ft 50cm ( ) 1ft 30cm If the power distribution circuit does not have an earth or the ground does not comply with specifications, an grounding electrode must be installed. The corresponding accessories are NOT supplied with the air conditioner . Select an grounding electrode that complies with the specifications given [...]
-
Page 48
Fixing the Unit in Position The outdoor unit must be installed on a rigid and stable base to avoid any increase in the noise level and vibration, particularly if the outdoor unit is to be installed close to a neighbour . If it is to be installed in a location exposed to strong winds or at a height, the unit must be fixed to an appropriate support ([...]
-
Page 49
Connecting Up and Removing Air In the Circuit The outdoor units is loaded with sufficient R-22 refrigerant for 5 m(16 ft) of piping. The air in the indoor unit and in the pipe must be purged. If air remains in the refrigeration pipes, it will affect the compressor , reduce to cooling capacity and could lead to a malfunction. Refrigerant for air pur[...]
-
Page 50
Performing Leak T ests Before completing the installation (insulation of the hose and piping), you must check that there are no gas leaks. T o check for gas leaks on the... Then, using a leak detector , check the... Indoor unit Flare nuts at the end of sections A and B. Outdoor unit V alves on sections C and D. C D A B E- 50[...]
-
Page 51
Insulation Once you have checked that there are no leaks in the system, you can insulate the piping and hose. T o avoid condensation problems, place heat-resistant polyethylene foam separately around each refrigerant pipe. 1 Wind insulating tape around the pipes and drain hose. 2 Finish wrapping insulating tape around the rest of the pipes leading [...]
-
Page 52
Installing the Front Panel Open the electrical component box cover removing the screws. 1 Connect the cables of the front panel to the PCB as shown in figure. 2 Close the electrical component box cover and secure the screws. 3 Install the front panel using two hooks on the both sides of the indoor unit. 4 Secure the front panel to the indoor unit u[...]
-
Page 53
Setting Up Option Switches IMPORT ANT : Before setting up the option switches, always make sure that you have turned off the main power . ◆ Make sure that the No.2 and No.3 switches are at “ON” position. N N N N o o o o t t t t e e e e Main PCB in the Indoor Unit 0 1 2 3 4 5 6 7 One Tw o Three Four Five Six Seven Eight 8 9 A B C D E F Nine Te[...]
-
Page 54
Setting Up Option Switches (Cont.) Unit A (Address 0) Unit B (Address 1) Unit C (Address 2) CN20 Connector CN20 Connector Remove the CN20 connector in the sub PCB, if necessary , ref erring to the table below . (This pr ocedure is needed only when the user would like to control a gr oup by using the wired remote contr oller .) Sub PCB in the Indoor[...]
-
Page 55
Centralized Controller DIP Switch(DS01) OFF Switch Position OFF OFF OFF OFF OFF OFF OFF ON OFF ON OFF The air conditioner is operated by the controller adjusted last among the wired remote controller , wireless remote controller and centralized controller . A user can use wired/wireless remote controller when the centralized controller is switched [...]
-
Page 56
Setting Up Option Switches (Cont.) ◆ Before setting up the options, always make sure that you have switched off the main power . ◆ After adjusting the options, you should supply the power . Otherwise, the options will not be applied. N N N N o o o o t t t t e e e e Original Position of Option Switches The option switches are preset by the manuf[...]
-
Page 57
Wired Remote Controller Installation (Optional) Accessories Wired Remote Controller(1) Cable-T ie(2) Cable Clamp(5) TH M4 X 16 T apped Screw(7) E- 57 ENGLISH Wired Remote Controller Indoor Unit Disassemble the wired remote controller by using two grooves on the top of it. 1 Secure the rear cover of the wired remote controller on the wall with two s[...]
-
Page 58
Centralized Controller Installation (Optional) Accessories T ransmitter(1) Spacer Support(4) Cable-T ie(2) Centralized Controller(1) Cable-T ie(2) Cable Clamp(5) TH M4 X 16 T apped Screw(7) Open the centralized controller cover by using two grooves on the top of it. 1 Secure the rear cover of the centralized controller on the wall with two screws. [...]
-
Page 59
Connect the power cables. 6 Reassemble the centralized controller . 7 Cable Specifications N N N N o o o o t t t t e e e e Size of cables 0.75mm 2 ~1.25mm 2 Cable type Double-insulation, 2G 208-230V~, 60Hz Power Supply Connect the O1 and O2 terminals of the centralized controller to the O1 and O2 terminals on the electrical component box as shown i[...]
-
Page 60
Receiver & Display Unit Installation (Optional) E- 60 Accessories Wireless Remote Controller(1) Battery(2) FH M4 X 16 T apped Screw(2) Remote Controller Holder(1) Receiver & Display Unit(1) Disassemble four screws on the place where you would like to install the receiver & display unit, inside the front panel. 1 Remove the part of the f[...]
-
Page 61
Bio-Pure Filter Installation (Optional) Open the front grille by pulling the tabs on the grille. 2 Remove the safety clips to open the grille completely . 3 Pull out the air filter . 4 Locate the bio-pure filter on the center of the air filter . 5 Secure the bio-pure filter with four screws. 6 Reinstall the filter and the front grille. 7 Do not rem[...]
-
Page 62
Controlling a Group ∗ Y ou should adjust the option switches in the electrical component box or on the PCB of the wired remote controller . ∗ Before setting up the option switches, always make sure that you have turned off the main power. ∗ After adjusting the options, you should supply the power . Otherwise, the options will not be applied. [...]
-
Page 63
A user can turn on/off up to sixteen air conditioners by using the centralized controller . In this case, the user can turn on/of f all air conditioners or a specific air conditioner connected with the centralized controller . And each air conditioner can be controlled by its own remote controller(s) depending on the setting. Connect the O1 and O2 [...]
-
Page 64
Checking and T esting Operations Supply the power and switch on the air conditioner . 1 Press T est button more than 3 seconds without selecting any mode. Result : The air conditioner runs in COOL mode for 3 minutes. 2 Check that user's option(s) and the outdoor unit operate properly . 3 Press the Swing( ) button and check that the air flow bl[...]
-
Page 65
Supply the power and switch on the air conditioner . 1 Remove the remote controller batteries. 2 Insert the batteries pressing the On T imer and Off T imer buttons at the same time. 3 Stop pressing the buttons after inserting the batteries. 4 Wireless Remote Controller Press the (ON / OFF) button. Result : The air conditioner runs in COOL mode for [...]
-
Page 66
T roubleshooting E- 66 If the error occurs, and the error code are displayed on the wired remote controller . The error code blinks for 5 seconds and it disappears. If you would like to see the error code after disappearing it, press the T est button. Meaning of Error Code The error code is composed of two-digit figures or letters. The first means [...]
-
Page 67
E- 67 ENGLISH If the error occurs, the indicators on the receiver & display unit displays the error . Meaning of Error Code Checking area ◆ Indoor unit thermistor sensor ◆ PCB of the indoor unit Meaning Indicators Indoor unit thermistor sensor error ◆ Indoor unit pipe thermistor sensor ◆ PCB of the indoor unit Indoor unit pipe thermisto[...]
-
Page 68
Explaining Operations to the Owner Before leaving the premises on which you have installed the air conditioner , you should explain the following operations to the owner , making reference to the appropriate pages in the owner’ s instruction booklet. How to start and stop the air conditioner . 1 How to select the operating mode and adjust the tem[...]
-
Page 69
Memo E- 69[...]
-
Page 70
ELECTRONICS THIS AIR CONDITIONER IS MANUF ACTURED BY : ESTE AIRE ACONDICIONADO HA SIDO F ABRICADO POR: CE CLIMA TISEUR EST FABRIQUE P AR: Printed in Korea[...]