Sanyo CH1822 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Sanyo CH1822, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Sanyo CH1822 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Sanyo CH1822. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Sanyo CH1822 should contain:
- informations concerning technical data of Sanyo CH1822
- name of the manufacturer and a year of construction of the Sanyo CH1822 item
- rules of operation, control and maintenance of the Sanyo CH1822 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Sanyo CH1822 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Sanyo CH1822, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Sanyo service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Sanyo CH1822.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Sanyo CH1822 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    HIGH EFFICIENCY SERVICE MANUAL (Basic Information) KHS1822 / CH1822 SPLIT SYSTEM AIR CONDITIONER 8526481021800 REFERENCE NO. WM – 700796 W Indoor Unit Outdoor Unit CH1822 KHS1822 92-267 S/M (Basic) 00.12.13 10:42 AM ページ A[...]

  • Page 2

    92-267 S/M (Basic) 00.12.13 10:42 AM ページ i[...]

  • Page 3

    ii WM – 700796 SER VICE MANUAL KHS1822 / CH1822 (Basic Information) 92-267 S/M (Basic) 00.12.13 10:42 AM ページ ii[...]

  • Page 4

    iii WM – 700796 IMPORT ANT! Please Read Before Starting This air conditioning system meets strict safety and operating standards. As the installer or service person, it is an important part of your job to install or service the system so it operates safely and efficiently. For safe installation and trouble-free operation, you must: ● Carefully [...]

  • Page 5

    T able of Contents Page 1. OPERA TING RANGE ............................................................................................................................... 1 2. SPECIFICA TIONS .................................................................................................................................... 2 Unit Specifications ..[...]

  • Page 6

    1 WM – 700796 1. OPERA TING RANGE Temperature Indoor Air Intake Temp. Outdoor Air Intake Temp. Cooling Maximum 95°F DB / 71°F WB 115°F DB Minimum 67°F DB / 57°F WB 67°F DB Heating Maximum 80°F DB / 67°F WB 75°F DB / 65°F WB Minimum — DB / — WB 17°F DB / 15°F WB KHS1822 / CH1822 92-267 S/M (Basic) 00.12.13 10:42 AM ページ 1[...]

  • Page 7

    2 WM – 700796 Model No. Indoor unit KHS1822 Outdoor unit CH1822 Cooling Heating Capacity BTU/ h 16,500 / 16,000 18,000 / 17,600 kW 4.84 / 4.69 5.27 / 5.16 Air circulation (High) cu. ft / min. 440 / 420 Moisture removal (High) Pints / h 5.3 / 5.2 Phase, Frequency Hz Single, 60 Voltage rating V 230 / 208 230 / 208 Available voltage range V 187 to 2[...]

  • Page 8

    WM – 700796 3 3. DIMENSIONAL DA T A Indoor Unit: KHS1822 Outdoor Unit: CH1822 38-31/32 14-3/16 7-25/32 Rear panel (Center point of gravity) Drain hose O.D. 1-1/4 Narrow tube O.D. 1/4 Wide tube O.D. 5/8 Center of tubing hole (For right rear) 5-19/32 1-61/64 Wireless remote control unit 6-7/64 2-13/64 19/32 Check port 1/4 narrow tubing service valv[...]

  • Page 9

    4. COOLING CAP ACITY 230V KHS1822 / CH1822 4 WM – 700796 TC: Total Cooling Capacity (BTU/ H) SHC: Sensible Heat Capacity (BTU/ H) kW: Compressor Input (kW) Remarks: Rating conditions (* mark) are: Outdoor ambient temperature 95°F DB Indoor unit entering air temperature 80°F DB / 67°F WB Rating Capacity: 16,500 BTU/ H Air Flow Rate: 440 CFM Eva[...]

  • Page 10

    5 WM – 700796 208V KHS1822 / CH1822 TC: Total Cooling Capacity (BTU/ H) SHC: Sensible Heat Capacity (BTU/ H) kW: Compressor Input (kW) Remarks: Rating conditions (* mark) are: Outside ambient temperature 95°F DB Indoor unit entering air temperature 80°F DB / 67°F WB Rating Capacity: 16,000 BTU/ H Air Flow Rate: 420 CFM Evaporator Condenser Ent[...]

  • Page 11

    6 WM – 700796 5. HEA TING CAP ACITY 1 Phase 60Hz 230V Indoor Entering Air Temperature 70°F Temperature of Air Entering Outdoor Coil (°F DB at 75% RH) Heating Capacity (BTU/h) 30,000 25,000 20,000 15,000 10,000 5,000 23 (–5) 32 (0) 41 (5) 50 59 (15) 68 (20) 75°F (23.7°C) 47 (8.3) Heat-pump capacity 17 (–8.3) 18,000 24,120 Heat-pump with ba[...]

  • Page 12

    7 WM – 700796 1 Phase 60Hz 208V Indoor Entering Air Temperature 70 ° F Temperature of Air Entering Outdoor Coil ( ° F DB at 75% RH) Heating Capacity (BTU/h) 30,000 25,000 20,000 15,000 10,000 5,000 23 ( – 5) 32 (0) 41 (5) 50 59 (15) 68 (20) 75 ° F (23.7 ° C) 47 (8.3) Heat-pump capacity 17 ( – 8.3) 17,600 22,640 Heat-pump with back-up heat[...]

  • Page 13

    Heat exchanger Wide tube Accumulator Compressor Wide tube service valve Drier Check valve Strainer Capillary Muffler 4-way valve Narrow tube service valve O.D. 5/8" ( ø 15.88 mm) Narrow tube O.D. 1/4" ( ø 6.35 mm) Heat exchanger Check port ( ) Muffler P Disharge pressure regulator Capillary Modulator Indoor unit Outdoor unit Heat exchan[...]

  • Page 14

    9 WM – 700796 7. ELECTRICAL DA T A ● Electrical Characteristics KHS1822 / CH1822 Remarks: Rating conditions are: Cooling: Outside air temperature 95°F DB / 75°F WB Indoor unit entering air temperature 80°F DB / 67°F WB Heating: Outside air temperature 47°F DB / 43°F WB Indoor unit entering air temperature 70°F WB Performance at Indoor Un[...]

  • Page 15

    10 WM – 700796 ● Electric Wiring Diagram Indoor Unit: KHS1822 Terminal plate 1 2 3 4 FROM OUTDOOR UNIT 3 3 1 1 3 3 2 2 1 1 1 1 2 2 BLK BLK BLK BLK 1 1 2 2 SG-OUT 3P SUP 2P 2P 2P SEC TH2 TH1 1 2 1 2 1 2 1 2 2P PRY 19 19 19 Switch assy Receiver assy Connector Switch assy HM FM L LL YEL VLT WHT 23 14 23 14 GRY BRN PNK GRY WHT VLT YEL FM GRN G CONT[...]

  • Page 16

    11 WM – 700796 Outdoor Unit: CH1822 1 1 2 2 1 1 2 2 1 1 3 3 1 1 2 2 1 12 2 1 12 2 1 1 1 2 2 1 1 2 2 1 1 2 2 1 1 2 2 2P PRY 2P SEC TH1 TH2 TH3 LO PRS RED BLK BLK BLK BLK BLK BLK Thermistor (coil) Thermistor (air temp) Thermistor (discharge) FM 2P CM CT SG-IN 2P SUP SC2 PNK BLK Connector CONTROLLER P S BRN BRN WHT WHT Power transformer Solenoid coi[...]

  • Page 17

    For parts or service contact SFS Corporation: 1200 West Artesia Blvd., Compton, California 90220 Printed in U.S.A. CORPORATION 1991/Nov./12M SANYO Canada Inc.: Toronto, Ont. M4H 1M6 In Canada WM – 700796 H408/12M Printed in U.S.A. 92-267 S/M (Basic) 00.12.13 10:42 AM ページ 12[...]