Go to page of
Similar user manuals
-
Air Conditioner
Sanyo 26KS72R
2 pages 0.51 mb -
Air Conditioner
Sanyo 36X72R
1 pages 0.13 mb -
Air Conditioner
Sanyo TS3632
24 pages 1.06 mb -
Air Conditioner
Sanyo TH3672R / CH3672R
180 pages 8.27 mb -
Air Conditioner
Sanyo STW-2 Series
12 pages 0.26 mb -
Air Conditioner
Sanyo 12KS71
1 pages 0.13 mb -
Air Conditioner
Sanyo STW0922C2
1 pages 0.47 mb -
Air Conditioner
Sanyo SAP-K18AP
37 pages 1.77 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Sanyo CMH1822, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Sanyo CMH1822 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Sanyo CMH1822. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Sanyo CMH1822 should contain:
- informations concerning technical data of Sanyo CMH1822
- name of the manufacturer and a year of construction of the Sanyo CMH1822 item
- rules of operation, control and maintenance of the Sanyo CMH1822 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Sanyo CMH1822 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Sanyo CMH1822, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Sanyo service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Sanyo CMH1822.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Sanyo CMH1822 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
SERVICE MANUAL (Basic Information) CMH1822 / KMH0922 ( ✕ 2) SPLIT SYSTEM AIR CONDITIONER 8526481017400 REFERENCE NO. WM – 700700 W Indoor Unit Outdoor Unit CMH1822 KMH0922 92-144 S/M (Basic) 00.12.13 10:32 AM ページ A[...]
-
Page 2
92-144 S/M (Basic) 00.12.13 10:32 AM ページ B[...]
-
Page 3
ii WM – 700700 SER VICE MANUAL CMH1822 / KMH0922 ( × 2) (Basic Information) 92-144 S/M (Basic) 00.12.13 10:32 AM ページ ii[...]
-
Page 4
WM – 700700 IMPORT ANT! Please Read Before Starting This air conditioning system meets strict safety and operating standards. As the installer or service person, it is an important part of your job to install or service the system so it operates safely and efficiently. For safe installation and trouble-free operation, you must: ● Carefully read[...]
-
Page 5
T able of Contents Page 1. OPERA TING RANGE ............................................................................................................................... 1 2. SPECIFICA TIONS .................................................................................................................................... 2 Unit Specifications ..[...]
-
Page 6
1 WM – 700700 1. OPERA TING RANGE Temperature Indoor Air Intake Temp. Outdoor Air Intake Temp. Maximum 95°F DB / 71°F WB 115°F DB Minimum 67°F DB / 57°F WB 67°F DB CMH1822 / KMH0922 ( × 2) 92-144 S/M (Basic) 00.12.13 10:32 AM ページ 1[...]
-
Page 7
DATA SUBJECT TO CHANGE WITHOUT NOTICE. Remarks: Rating conditions are: Cooling: Outside air temperature 95°F DB / 75°F WB Indoor unit entering air temperature 80°F DB / 67°F WB Heating: Outside air temperature 47°F DB / 43°F WB Indoor unit entering air temperature 70°F DB Model No. Outdoor unit CMH1822 Applicable indoor unit KMH0922 No. of i[...]
-
Page 8
3 WM – 700700 DATA SUBJECT TO CHANGE WITHOUT NOTICE. Remarks: Rating conditions are: Cooling: Outside air temperature 95°F DB / 75°F WB Indoor unit entering air temperature 80°F DB / 67°F WB Heating: Outside air temperature 47°F DB / 43°F WB Indoor unit entering air temperature 70°F WB Model No. KMH0922 Type Wall-mounted Cooling Heating Ca[...]
-
Page 9
WM – 700700 4 3. DIMENSIONAL DA T A Outdoor Unit: CMH1822 Indoor Unit: KMH0922 O.D. 3/8" wide tubing service valve 2-9/32 3-3/4 11-7/32 1-3/16 2-1/4 32-11/16 3/4 24-13/16 Air discharge Air intake Air intake 21-3/16 5-3/4 12-3/12 13-1/4 4 × 15/32 dia. hole O.D. 1/4" narrow tubing service valve O.D. 3/8" wide tubing service valve O.[...]
-
Page 10
4. COOLING CAP ACITY 230V CMH1822 / KMH0922 ( × 1) 5 WM – 700700 TC: Total Cooling Capacity (BTU/ H) SHC: Sensible Heat Capacity (BTU/ H) kW: Compressor Input (kW) Remarks: Rating conditions (* mark) are: Outside ambient temperature 95°F DB Indoor unit entering air temperature 80°F DB / 67°F WB Rating Capacity: 8,800 BTU/ H Air Flow Rate: 220[...]
-
Page 11
6 WM – 700700 208V CMH1822 / KMH0922 ( × 1) TC: Total Cooling Capacity (BTU/ H) SHC: Sensible Heat Capacity (BTU/ H) kW: Compressor Input (kW) Remarks: Rating conditions (* mark) are: Outside ambient temperature 95°F DB Indoor unit entering air temperature 80°F DB / 67°F WB Rating Capacity: 8,700 BTU/ H Air Flow Rate: 210 CFM Evaporator Conde[...]
-
Page 12
7 WM – 700700 5. HEA TING CAP ACITY 1 Phase 60Hz 230V Model Name: CMH1822 / KMH0922 ( × 1) Indoor Entering Air Temperature 70 ° F Temperature of Air Entering Outdoor Coil ( ° F D.B. at 75% RH) Heating Capacity (BTU/h) 30,000 25,000 20,000 15,000 10,000 5,000 23 ( – 5) 32 (0) 41 (5) 50 59 (15) 68 (20) 75 ° F (23.7 ° C) 47 (8.3) 13,100 Heat-[...]
-
Page 13
8 WM – 700700 1 Phase 60Hz 208V Model Name: CMH1822 / KMH0922 ( × 1) Indoor Entering Air Temperature 70 ° F Temperature of Air Entering Outdoor Coil ( ° F D.B. at 75% RH) Heating Capacity (BTU/h) 30,000 25,000 20,000 15,000 10,000 5,000 23 ( – 5) 32 (0) 41 (5) 50 59 (15) 68 (20) 75 ° F (23.7 ° C) 47 (8.3) 9,800 12,300 Heat-pump with back-u[...]
-
Page 14
Heat exchanger Narrow tube O. D. 1/4" (6.35mm) Wide tube O.D. 3/8" (9.52mm) Service valve Muffler Accumulator Compressor A Reversing valve Service valve Dehydrator Capillary tube ( ) Check valve Strainer Heat exchanger Narrow tube O.D. 1/4" (6.35mm) Wide tube O.D. 3/8" (9.52mm) Service valve Muffler Accumulator Compressor B Reve[...]
-
Page 15
10 WM – 700700 7. ELECTRICAL DA T A ● Electrical Characteristics CMH1822 / KMH0922 ( × 1) Remarks: Rating conditions are: Cooling: Outside air temperature 95°F DB / 75°F WB Indoor unit entering air temperature 80°F DB / 67°F WB Heating: Outside air temperature 47°F DB / 43°F WB Indoor unit entering air temperature 70°F WB Performance at[...]
-
Page 16
11 WM – 700700 ● Electrical Wiring Diagram Outdoor Unit: CMH1822 CMA S C R BLK RED Compressor motor A PTC. A WHT BLK WHT OLR. A CMB R C S RED Compressor motor B WHT OLR. B BLK WHT BLK PTC. B BLK 1 2 7 6 5 4 3 2 1 3 4 12 3 4 12 1 2 1 2 CONTROLLER S. CB RED RED YEL YEL 1 2 1 2 S. CB S. CB S. CA RED RED WHT WHT 1 2 1 2 S. CA S. CA WHT GRY GRY WHT [...]
-
Page 17
12 WM – 700700 Indoor Unit: KMH0922 1 1 2 1 2 1 1 12 12 2 2 5 5 4 4 3 3 1 1 5 5 4 4 3 3 1 1 2 2 6 6 Thermistor 2P Supply CONTROLLER Remote control switch Fan motor FM 2 3 1 2 1 2 BRN PNK GRY YEL WHT VLT GRY ORG WHT VLT Capacitor PNK BRN 1 2 1 2 WHT WHT P S Transformer BRN Terminal plate FROM OUTDOOR UNIT GRN G G BRN 5 5 4 4 3 3 2 2 1 1 YEL YEL 1 [...]
-
Page 18
For parts or service contact SFS Corporation: 1200 West Artesia Blvd., Compton, California 90220 Printed in U.S.A. CORPORATION 1991/Nov./12M SANYO Canada Inc.: Toronto, Ont. M4H 1M6 In Canada WM – 700700 H407/12M Printed in U.S.A. 92-144 S/M (Basic) 00.12.13 10:32 AM ページ 13[...]