Go to page of
Similar user manuals
-
Air Conditioner
Sanyo C2432
17 pages 0.42 mb -
Air Conditioner
Sanyo C3082
104 pages 6.51 mb -
Air Conditioner
Sanyo C4232
66 pages 0.38 mb -
Air Conditioner
Sanyo XS2432
24 pages 1.06 mb -
Air conditioner
Sanyo SAP-CRV126EH
65 pages 1.61 mb -
Air Conditioner
Sanyo KHS3072R
2 pages 0.62 mb -
Air Conditioner
Sanyo KS1271
50 pages 2.47 mb -
Air Conditioner
Sanyo 09KLS51
3 pages 0.02 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Sanyo KS2462R, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Sanyo KS2462R one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Sanyo KS2462R. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Sanyo KS2462R should contain:
- informations concerning technical data of Sanyo KS2462R
- name of the manufacturer and a year of construction of the Sanyo KS2462R item
- rules of operation, control and maintenance of the Sanyo KS2462R item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Sanyo KS2462R alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Sanyo KS2462R, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Sanyo service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Sanyo KS2462R.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Sanyo KS2462R item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
Pub. OI-85464189508000 ©SANYO 2002 INS TRUCTION MANU AL Split S yst em Air Conditioner Sav e These Instr uctions! Printed on Recycled Paper KS2462R COOL/DR Y Model In order to protect the environment, this air conditioner uses the new refrigerant R41 0A.[...]
-
Page 2
Features This air conditioner is equipped with cooling and drying functions. Details on these functions are provided below; refer to these descriptions when using the air conditioner . • Microprocessor Controlled Operation The interior compartment of the remote control unit contains several features to facilitate automatic operation, each logical[...]
-
Page 3
Contents Page Features .................................................................................................................. 2 Product Information .............................................................................................. 3 Alert Symbols ...............................................................................[...]
-
Page 4
Installation Location • We recommend that this air conditioner be installed properly by qualified installation technicians in accordance with the Installation Instructions provided with the unit. • Before installation, check that the voltage of the electric supply in your home or office is the same as the voltage shown on the nameplate. • Do [...]
-
Page 5
Names of Parts NOTE This illustration is based on the external appearance of a standard model. Consequently , the shape may differ from that of the air conditioner which you have selected. This air conditioner consists of an indoor unit and an outdoor unit. Y ou can control the air conditioner with the remote control unit. Air Intakes Air from the [...]
-
Page 6
Unit Display and Operation Selector REMOTE CONTROL receiver This section picks up infrared signals from the remote control unit (transmitter). Operation selector ON position This position is for operating the air conditioner with the wireless remote control unit. Set the selector normally in this position. OFF position Switch the selector to the OF[...]
-
Page 7
Remote Control Unit (Display) (1) Operation mode MILD DRY................................ COOL ....................................... (2) Fan speed AUTO ....................................... HIGH ........................................ MEDIUM .................................. LOW ......................................... (3) T emperature setti[...]
-
Page 8
8 OI- 508 - 0 8 E G Sensor T ransmitt er Display NIGHT SETBA CK button 1 HR. TIMER but ton MODE select or button FLAP but ton ADDRESS switch (Cov er closed) ON/OFF operation but ton T emperat ure set ting butt ons F AN SPEED selector but ton TIMER SELECT but ton TIMER AND PRESENT TIME set ting butt ons PROGRAM but ton A CL butt on SENSOR but ton Ba[...]
-
Page 9
9 OI- 508 -9 E G Remote Contr ol Unit (continued) Progr am butt on F or details, see “Set ting the Timer” . Press this but ton to select the mode you want to program. TIMER SELECT but ton No display : The timer does not operate. : The air conditioner stops at the set time. : The air conditioner starts at the set time. : The air conditioner stop[...]
-
Page 10
Using the Remote Control Unit How to Install Batteries NOTE • The batteries last about six months, depending on how much you use the remote control unit. Replace the batteries when the remote control unit ’ s displa y fail s t o indicate , o r whe n th e remot e contro l canno t b e used t o chang e th e ai r conditioner ’ s settings. • Use[...]
-
Page 11
11 OI -508 - 1 1 E G Using the Remote Contr ol Unit (continued) Mounting the Remote Contr ol Unit When attac hing to w all 1) Confirm the indoor unit beeps when the ON/OFF but ton is pressed at the w all location where the remote control unit is to be attac hed, then attac h the holder to the w all. 2) When taking out the remote control unit, pull [...]
-
Page 12
Set the FAN SPEED selector button to the setting you want. If the fan speed is set to (Automatic), the fan speed switches automatically, according to the difference between the actual room temperature and the temperature setting. Operation with the Remote Control Unit 1. Manual Operation NOTE Check that the circuit breaker on the power panel is tur[...]
-
Page 13
Operation with the Remote Control Unit (continued) NOTE • This appliance has a built-in three minutes time delay circuit to ensure reliable operation. When the operation button is pressed, the compressor will start running within three minutes. In the event of power failure, the unit will stop. When the power is restored, the unit will restart au[...]
-
Page 14
Operation with the Remote Control Unit (continued) 3. Night Setback Mode The Night Setback Mode is used for saving energy . Press the NIGHT SETBACK button while the air conditioner is operating. The mark appears in the display . T o cancel the night setback function, press the NIGHT SETBACK button again. In Cooling and DRY Mode: ( and ) When the ni[...]
-
Page 15
Special Remarks ‘ ‘DRY’ ’ ( ) Operation How it works? • Once the room temperature reaches the level that was set, the unit repeats the cycle of turning on and off automatically . • During DRY operation, the fan speed is automatically set to LOW or VERY LOW ; the fan speed then switches back and forth between LOW (for 20 seconds) and VER[...]
-
Page 16
16 OI- 508 - 1 6 E G S et ting the T imer 1 . Ho w to set the pr esent time (Example) T o set to 9:1 0 pm. Operation Indication 1 . Press the P rogram but ton ( ) three times. 2. • Press the HH but ton until PM 9 is displayed. • Press the MM but ton until 1 0 is displayed. The time indication alone blinks. The display will automatically stop bl[...]
-
Page 17
17 OI- 508 - 1 7 E G Set ting the Timer (continued) 3 . How t o set the ON time (Example) T o star t operation at 7:1 0 am. Operation Indication 1 . Press the P rogram but ton ( ) twice. 2. • Press the HH but ton until AM 7 is displayed. • Press the MM but ton until 1 0 is displayed. 3. Press the ON/OFF but ton to star t the air conditioner . 4[...]
-
Page 18
18 OI- 508 - 1 8 E G S et ting the 1 -Hour OFF T imer 1 . 1 -Hour OFF Timer This function causes the unit t o operat e for one hour and then st op, r egar dless of whether the unit is on or of f when this butt on is pr essed. The indicator in the display indicates that this function is operating. Set ting procedur e: Reg ardless of whether the unit[...]
-
Page 19
19 OI- 508 - 1 9 E G Adjusting the Airflow Direction 1 . Hor izontal The horiz ontal airflow can be adjusted by moving the ver tical vanes with your hands to the lef t or right. CA UTION When the humidity is high, the ver tical v anes should be in the fr ont position dur ing the cooling or drying operation. If the ver tical v anes are positioned al[...]
-
Page 20
20 OI- 508 -20 E G Operation without the R emote Control Unit If you have lost the remote control unit or it has trouble, follow the steps below . 1. When the air conditioner is not running If you want to turn on the air conditioner , switc h the operation selector to the OFF position, and then to the ON position. NO TE The set temperature and fan [...]
-
Page 21
21 OI- 508 -21 E G 1. With the ˝FRON T˝ mark facing you, slide the anti-mold filter up into the unit and then lower the handle into the groove on the unit. 2. After installing the anti-mold filter , press the locations marked by the arrows ( ) and close the air intake grille. Car e and Cleaning (continued) Anti-mold filter The anti-mold filter be[...]
-
Page 22
22 OI- 508 -22 E G Car e and Cleaning (continued) Air cleaning filter (not pr ovided) The air cleaning filter remo ves dust and dirt from the air , and reduces odor s and smoke from tobacco. NO TE The air clean filter is not provided with the air conditioner and must be purc hased separately . Ask for the STK-F4B model when purc hasing. W ARNING Th[...]
-
Page 23
23 OI- 508 -23 E G Car e and Cleaning (continued) Removing and r emounting the air intak e gr ille • With the air intake grille open all the way , grip both arms with your hands and pull toward you to remove. T o remount, hold the air intak e grille roughly horiz ontal and push it in until the arm shaf ts fit into the indentations in the main uni[...]
-
Page 24
24 OI- 508 -24 E G T roubleshooting If your air conditioner does not work properly , fir st c hec k the following points before requesting service. If it still does not work properly , contact your dealer or service center . T rouble P ossible Cause Remedy Air conditioner does not run at all. 1 . P ower failure. 2. Leakage circuit break er tripped.[...]