Sanyo MPR-311D(H) manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Sanyo MPR-311D(H), along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Sanyo MPR-311D(H) one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Sanyo MPR-311D(H). A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Sanyo MPR-311D(H) should contain:
- informations concerning technical data of Sanyo MPR-311D(H)
- name of the manufacturer and a year of construction of the Sanyo MPR-311D(H) item
- rules of operation, control and maintenance of the Sanyo MPR-311D(H) item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Sanyo MPR-311D(H) alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Sanyo MPR-311D(H), and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Sanyo service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Sanyo MPR-311D(H).

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Sanyo MPR-311D(H) item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    INSTRUCTION MANUAL Pharmaceutical Refrigerator =MPR-311 (II) MPR-3110(H) ---MPR-314DR{II} MPR-311 DR(H)[...]

  • Page 2

    Note: 1. No part of this manual may be reproduced in any form with the expressed written permission of SANYO. 2. The contents of this manual are subject to change without notice. 3. Please contact SANYO if any point in this manual is unclear or if there are any inaccuracies. SANYO Electric Co., Ltd. All rights reserved. Printed in Japan.[...]

  • Page 3

    CONTENTS PRECAUTIONS FOR SAFE OPERATION P. 1 CAUTIOINS FOR USAGE P.5 NAME AND FUNCTION OF PARTS P. 6 BEFORE COMMENCING OPERATION P.8 AUTOMATIC TEMPERATURE RECORDER P.10 START-UP OF UNIT P. 11 OPERATING INSTRUCTIONS P. 12 MAINTENANCE P. 14 TROUBLE SHOOTING P. 15 ENVIRONMENTAL CONDITIONS P.15 DISPOSAL OF UNIT P. 15 SPECIFICATIONS P. 16 PERFORMANCE P.[...]

  • Page 4

    PRECAUTIONS FOR SAFE OPERATION o o o o e ~WARNING Do not use the unit outdoors. Current leakage or electric shOck may result if the unit is exposed to rainwater. Only qualified engineers or service personnel should install the unit. The installation by unqualified personnel may cause gas or liquid leakage, electric shock or fire. Be sure to install[...]

  • Page 5

    PRECAUTIONS FOR SAFE OPERATION I o o o ~WARNING Never disassemble, repair, or modify the unit yourself. Any such work carried out by an unauthorized person may result in fire or injury due to a malfunction. Make the power supply to the unit is disconnected when the fluorescent light is replaced as this will prevent electric S110ck. Disconnect the p[...]

  • Page 6

    PRECAUTIONS FOR SAFE OPERATION o ~CAUTION Always hold the handle when closing the door. This will prevent the likelihood of a trapped finger. Never lean or press on the glass. Intentional force may cause injury if the glass breaks. Do not lean on the door. This may cause injury if the unit tips over. Check the filter mentioned in this manual and cl[...]

  • Page 7

    CAUTIONS FOR USAGE G) If the unit is unplugged or the power to the unit is interrupted, do not restart the unit for at least 5 minutes. This protects the compressor. ® This inner cabinet is refrigerated by the forced circulation of cooled air inside the chamber. Ensure that the intake and exhaust vents are not blocked. @ Adequate space should be p[...]

  • Page 8

    NAME AND FUNCTION OF PARTS .-. ii~r . ..""''' - -~ --- @ (Q) @ @ - IIIII il ' .. 1 i "- ~ I , .. . MPR-311 D(H) ([) Door Consists of double pair glass with heat ray reflection film. ® Frame (Product unit) @ Fluorescent lamp 20W white light. For replacement, refer to page 13. @ Air circulating fan Circulate the co[...]

  • Page 9

    NAME AND FUNCTION OF PARTS I Control panel ® 0' 0' II II El 0 0 0 ,0 " 0 0" DEFROST "" ~" " . - _:.All .. ._. TeMP. CONTROL UGHT MPR·311(H) ®@@ @ ® 0' II sll AA El 0 0 0 0 0 0" ~~ 'ow "~ ,~ DEFROST w,'m. o~. " .=. .~- lEMPERATIJRE lEMP. CONTROL UGHT MPR·311D(H), MPR·311DR([...]

  • Page 10

    BEFORE COMMENCING OPERATION Installation site To operate this unit property and to obtain maximum performance, install the unit in a location with the following conditions. <D A location not subjected to direct sunlight Installation in a location subjected to direct sunlight may lead· to inadequate cooling. ® A location with adequate ventilati[...]

  • Page 11

    BEFORE COMMENCING OPERATION I Installation <D Remove the packaging materials and tapes Remove all transportation packaging materials and tapes. Open the doors and ventilate the unit. If the outside panels are dirty, clean them with a mild detergent and rinse with water. ® Adjust the height adjusting screws Extend the height adjusting screws by [...]

  • Page 12

    AUTOMATIC TEMPERATUER RECORDER I Automatic temperature recorder (optional) To record the chamber temperature, an optional automatic temperature recorder is available. Please consult with our sales department or agency for recorder installation. The available recorder model is MTR-0620LH. Moreover, a mounting kit (MDF-53RO(H)) is also necessary for [...]

  • Page 13

    START-UP OF UNIT The following procedure should be adhered to for initial start-up and continuous operation. <D Connect unit to dedicated power supply. Do not put any product in the unit at this time. ® When the power is initially applied, the audible alarm may sound. Set the BUZZER switch to OFF to silence the alarm. @ Set the desired temperat[...]

  • Page 14

    .-; OPERATING INSTRUCTIONS I Temperature set Set up of chamber tern perature Table 1 and 2 show the basic operation method. Follow the key operation sequence indicated in the table. The example in the table is based on the assumption that the chamber temperature set at 1 GOC. The unit is set at the factory to obtain the proper temperature (5°C) au[...]

  • Page 15

    OPERATING INSTRUCTIONS I Alarm, Safety function and Self diagnostic function This unit has the alarm and safety functions shown in Table 3 and Table 4, and also a self diagnostic function. Table 3 Alarm and safety functions (MPR-311 H)) Alarm or safety Situation Indication Buzzer Safety operation High temp. alarm The chamber temp. is High temp. ala[...]

  • Page 16

    MAINTENANCE &WARNING .. Disconnect Always ~ supply to the unit maintenance of the disconnect the power prior to any repair or unit in order to prevent electric shock or injury. Cleaning G) Clean this unit once a month. Regular cleaning keeps the unit looking new. ® Use a dry cloth to wipe off small amounts of dirt on the outside and inside of [...]

  • Page 17

    TROUBLE SHOOTING If the unit malfunctions, check out the following before calling for service. 1. If nothing operates even when switched on 1) Is unit connected to the power supply? 2) Is there a power failure? 3) Is the fuse blown.or the circuit breaker inactivated? 2. When alarm is activated When alarm lamp and buzzer are activated, follow proced[...]

  • Page 18

    SPECIFICATIONS Name Pharmaceutical Refrigerator Model MPR-311(H) MPR-311 D(H) • MPR-311DR(H) External dimensions W800 x D450x H1800 (mm) Internal dimensions W720 x D350x H1435 (mrn) Effective capacity 340 L Exterior Acrylic finish baked on zinc galvanized steel Interior Acrylic finish baked on zinc galvanized steel Stainless steel Door Double lay[...]

  • Page 19

    & CAUTION Please fill in this form before servicing. Hand over this form to the service engineer to keep for his and your safety. Safety check sheet 1. Refrigerator contents: DYes DNo Risk of infection: DYes DNo Risk of toxicity: DYes DNo Risk from radioactive sources: DYes DNo (List all potentially hazardous materials that have been stored in [...]