Sanyo STK-RCS-7TWSUA manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Sanyo STK-RCS-7TWSUA, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Sanyo STK-RCS-7TWSUA one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Sanyo STK-RCS-7TWSUA. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Sanyo STK-RCS-7TWSUA should contain:
- informations concerning technical data of Sanyo STK-RCS-7TWSUA
- name of the manufacturer and a year of construction of the Sanyo STK-RCS-7TWSUA item
- rules of operation, control and maintenance of the Sanyo STK-RCS-7TWSUA item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Sanyo STK-RCS-7TWSUA alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Sanyo STK-RCS-7TWSUA, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Sanyo service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Sanyo STK-RCS-7TWSUA.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Sanyo STK-RCS-7TWSUA item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    TECHNICAL & SER VICE MANUAL STK-RCS-7TWSUA WIRED REMOTE CONTROLLER Destination: North America REFERENCE NO. SM 700799 Model No. STK-RCS-7TWSUA Product Code No. 1 852 353 85 FILE NO.[...]

  • Page 2

    When Wiring ELECTRICAL SHOCK CAN CAUSE SEVERE PERSONAL INJUR Y OR DEA TH. ONL Y A QUALIFIED, EXPERIENCED ELECTRICIAN SHOULD A TTEMPT TO WIRE THIS SYSTEM. SPECIAL PRECAUTIONS This symbol refers to a hazard or unsafe practice which can result in severe personal injury or death. This symbol refers to a hazard or unsafe practice which can result in per[...]

  • Page 3

    T able of Contents 1. SPECIFICA TIONS 2. APPLICABLE INDOOR UNITS 3. FUNCTIONS 4. SELF-DIAGNOSTICS 4-1. Self-Diagnostics Procedure 4-2. Self-Diagnostics T able (Ceiling Cassette T ype) 4-3. Self-Diagnostics T able (W all Mounted T ype) APPENDIX A  INSTRUCTION MANUAL APPENDIX B  INST ALLA TION INSTRUCTIONS  (STK-RCS-7TWSUA) APPENDIX C  IN[...]

  • Page 4

    1. SPECIFICATIONS 70.0 16.5 120.0 Item Signal Transmission Method Dedicated Remote Controller Cable DC5V supplied from Indoor Unit Liquid Crystal Set Temperature Indication (68 ºF to 86 ºF) Six Directions Indication AM and PM 12-Hour Indication (Minute Indication Unit: 1 minute) Displayed when indoor unit sensor is in use AUTO, HEAT, DRY and FAN [...]

  • Page 5

    XHS1271, XHS1872, XS1271, XS1872 KHS0971, KHS1271, KHS1872, KHS2472 KS0971, KS1271, KS1872, KS2472 KMHS0772, KMHS0972, KMHS1272, KMHS1872, KMHS2472 KMS0772, KMS0972, KMS1272, KMS1872, KMS2472 Ceiling Cassette T ype W all Mounted T ype T ype Indoor Unit Model No. 2. APPLICABLE INDOOR UNITS 3. FUNCTIONS When the unit is modified from one for wireless[...]

  • Page 6

    4. SELF-DIAGNOSTICS PROCEDURE After turning on power to the air conditioner, use the remote controller and follow the steps below to execute self- diagnostics. Step 1: Press and hold the remote controller NIGHT SET BACK (NSB) button and 1 HR TIMER button. Then, press and hold the ACL (reset) button with a pointed object such as the tip of a pen. Af[...]

  • Page 7

    4-2. Self-Diagnostics T able (Ceiling Cassette T ype) Since the indications cover various units, the corresponding parts listed below may not be present in some models. Indication on indoor unit .... OFF Ti mer HIGH POWER Code Diagnostics item sD iagnostics contents S01 Room temperature sensor failure Indoor heat exchanger sensor failure Compressor[...]

  • Page 8

    4-3. Self-Diagnostics T able (W all Mounted T ype) Since the indications cover various units, the corresponding parts listed below may not be present in some models. REMOTE CONTROL receiver (1) OPERATION lamp (2) TIMER lamp (3) QUIET lamp ION lamp OPERATION button INDOOR UNIT Indication on indoor unit .... OFF Ti mer Operation Code Diagnostics item[...]

  • Page 9

    INSTRUCTION MANUAL STK-RCS-7TWSUA (OI-852-6-4181-139-00-0) APPENDIX A A-1[...]

  • Page 10

    STK-RCS-7TWSU A © SANY O 2009 Pub . OI-85264181 139 000 INSTR UCTION MANU AL Wired Remote Controller MODE D’EMPLOI Télécommande Filaire This wired remote controller is designed f or both the “COOL/DR Y/HEA T Model” and “COOL/DR Y Model ” indoor unit. Bef ore using the remote controller , be sure to confir m the “model ty pe” specif[...]

  • Page 11

    2 CONTENTS Pa g e PRODUCT INFORMA TION ....... .......................................... .............. ...................... ............ ........... ... . 2 ALER T SYMBOLS ............. ................ .................... .................... ................ .................... ......... ........... . 2 INST ALLA TION LOCA TION ............[...]

  • Page 12

    3 FEA TURES • Micr oprocesso r Controlled Operation • 24-Hour ON or OFF Timer • 1-Hour OFF Ti mer •N i g h t S e t b a c k • A utomatic and 3-step F an Speed • Air Sweep Contr ol • A utomatic Restart Function f or P ower F ailure • Automatic Switching between Cooling and Heating (This function is a vail able only f or “Single use?[...]

  • Page 13

    4 REMO TE CONTROL UNIT Display Inf ormation on the operating condit ions is displa yed while the re mote control unit is s witched on. If the unit is turned off, only the mode t hat was set previously is sti ll displayed. F AN SPEED selector b utton : The air conditi oner automatically decides the f an speeds . : High f an speed : Medium f an speed[...]

  • Page 14

    5 Sensor A temperature sen sor inside the remote control unit senses the room te mperature. ON/OFF operation button This b utton is fo r tur ning the ai r conditioner on and off . 1 HR. TIMER b utton (1-HOUR OFF TIMER) : When y ou press this b utton, regardless of whether th e unit is operating or stoppin g, the unit operates f or one hour and t he[...]

  • Page 15

    6 OPERA TION WITH THE REMO TE CONTROL UNIT 1. A utomatic Operation (only f or COOL/DR Y/HEA T Model) • Single use This unit automat ically sw itches between coolin g operation and heating oper ation according to the diff erence betwe en the room temperature a nd the temperat ure setting. • Multiple use The air conditioner cal culates the diff e[...]

  • Page 16

    7 3. Adjusting the F an Speed A. A utoma tic fan speed Simply set the F AN SPEED se lector button to the position. This automatically sets the best fan speed for the room temperature. B. Manual fa n speed If you w ant to adjust fan speed manually during operation, just set the F AN SPEED selector button as desired. [ , , or ] 4. Fan Onl y 5. Night [...]

  • Page 17

    8 SETTING THE TIMER 1. How to set the present time (Example) T o set to 9:10 pm. 2. How to set the OFF time (Example) T o stop the air conditioner at 11:30 pm. T o cancel the setting, press the TI MER SELECT button twice . 3. How to set the ON time (Example) T o star t opera tion at 7:10 am. T o cancel the setting, press the TI MER SELECT button th[...]

  • Page 18

    9 USING THE 1-HOUR OFF TIMER 1. 1-Hour OFF Timer This function causes the unit to operate f or one hour and then stop, regar dless of whether the unit is on or off when this butto n is pressed. The indicator in the displa y indicates that this function i s operating. Setting pr ocedure: Regardless of whether t he unit is operating or stopped, press[...]

  • Page 19

    INSTALLATION INSTRUCTIONS (STK-RCS-7TWSUA) STK-RCS-7TWSUA (II-852-6-4190-481-00-1) APPENDIX B A-2[...]

  • Page 20

    I Parts supplied with the remote controller See T able 1. I Remote controller installation guidelines • Mount the remote controller 3.3 to 4.9 ft. (1 to 1.5 meters) off the floor where it can sense the average temperature of the room. • Do not mount the remote controller in a place exposed to direct sunlight or where it is exposed to outside ai[...]

  • Page 21

    2 A. Installing with in-wall junction box (1) Install the junction box (locally purchased) into the wall. (Figs. 2-a and 3) (2) Pass the wire harness through the junction box and conduit. (Fig. 3) (3) Insert a flathead screwdriver into the 5 tab locations and disconnect the back plate of the remote controller by lifting up slightly . (Fig. 2-b) The[...]

  • Page 22

    Fig. 8 Indicator Wire harness Ceiling panel T erminal cover Clamps 7P IND and 4P RC wiring connector 5P FLAP wiring connector Clamping strap FLAP RC IND 7P 4P 5P FLAP wiring connector Wire harness Remote controller Wire harness Control PCB Indicator 7P IND and 4P RC wiring connector Putty 3 I How to wire the remote controller (1) T urn OFF the powe[...]

  • Page 23

    4 Fig. 9 Fig. 10 Fig. 1 1 ON/OFF operation button 1 HR.TIMER button NIGHT SETBACK button ACL (Reset) button SENSOR button OPERA TION lamp TIMER lamp HIGH POWER lamp REMOTE CONTROL receiver OPERA TION button I How to T est Run the Air Conditioner After turning on the power of the air conditioner , use the remote controller and follow the steps below[...]

  • Page 24

    STK-KCW1 (II-852-6-4190-491-00-0) APPENDIX C INSTALLATION INSTRUCTIONS Installing the Connection Kit for Wall-Mounted Models () A-3[...]

  • Page 25

    I Installing the connection kit A. 7000 BTU, 9000 BTU, and 12000 BTU inverter models (1) Remove the air intake grille. (2) Remove the terminal cover . Pull out the thermistor , then remove the grille. • For details on steps (1) and (2), refer to the Installation Instructions included in the outdoor unit package. (3) Disengage the top cover from t[...]

  • Page 26

    (10) Pass the wire tube through the clamping strap, and temporarily fasten in place with the screw . Next, use a clamp and bind the wires together immediately above the clamping strap, and fasten in place with the screw in order to prevent pulling on the wire harness. (Fig. 6a) • Install the wire tube so that the wires cannot be damaged by the ed[...]

  • Page 27

    3 B. 18000 BTU and 24000 BTU inverter models (1) Remove the air intake grille. (2) Remove the terminal cover . Pull out the thermistor , then remove the grille. • For details on steps (1) and (2), refer to the Installation Instructions included in the outdoor unit package. (3) Disengage the top cover from the tabs on the sides of the component bo[...]

  • Page 28

    4 Fig. 9 Fig. 10 Fig. 1 1 ON/OFF operation button 1 HR.TIMER button NIGHT SETBACK button ACL (Reset) button SENSOR button OPERA TION lamp TIMER lamp QUIET lamp ION lamp I How to T est Run the Air Conditioner After turning on the power of the air conditioner , use the remote controller and follow the steps below to conduct the test run. (1) Set the [...]

  • Page 29

    SANYO Commercial Solutions A Division of SANYO North America Corporation 1300 Michael Drive, Suite A Wood Dale, IL 60191, U.S.A. Sanyo Canada Inc. 1-300 Applewood Crescent, Concord, Ontario L4K 5C7, CANADA Apr . / 2009 (T)[...]