Schneider Electric 3000 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Schneider Electric 3000, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Schneider Electric 3000 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Schneider Electric 3000. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Schneider Electric 3000 should contain:
- informations concerning technical data of Schneider Electric 3000
- name of the manufacturer and a year of construction of the Schneider Electric 3000 item
- rules of operation, control and maintenance of the Schneider Electric 3000 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Schneider Electric 3000 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Schneider Electric 3000, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Schneider Electric service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Schneider Electric 3000.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Schneider Electric 3000 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    990-1289E 04/2010 User M anua l English Sma rt -U PS ® RT 3000/5000/ 6000 VA 200-240 Vac Tower/Rack Mount 3U Uninterruptible Power Supply    2 009 AP C by S chn ei d er E l ect ri c. APC , t h e APC l o go , S mar t -UP S a nd P o wer C hu t e ar e o wn e d by S c hn ei der El e ctri c Indu strie s S .A.S., Ameri can Power C onv ersi on C[...]

  • Page 2

    [...]

  • Page 3

    . 1 I ntroduct ion Th e APC  by Sch n ei d er El ectr i c Smar t - UPS  RT is a hig h-p erfo rmanc e, uni nte rrup tib le po we r supply (UPS ) tha t prov ides protec tion f or electro n i c equi pment f r om ut ility powe r blackouts, b r ow nouts , s ags and su rges . T he U PS filte rs sm all u tility line fluc tuat ions a n d is ola te s [...]

  • Page 4

    2 Wir ing an d Co nnec ting t he UP S 5000/6000 VA XLI MO DE LS O NL Y : H ARDW IRING I NSTRUCTIO NS • Wir in g mu st be per for m ed by a qu al i fi ed el ectr i ci an . • Ins tall a high mag net ic 30 /32 A u tility circui t b reak e r . • Adh er e t o all na ti on al and l oca l el ect r i cal codes. • U se #10 AWG gauge (5 mm 2 ) wi r e[...]

  • Page 5

    . 3 C ONN ECTI NG T HE B ATT E RY MO DU LE S AN D A TTACHI NG THE F RONT B EZE L    [...]

  • Page 6

    4 B ASIC C ONN ECT O RS serial co m Po we r ma nage me n t s of tw ar e and inte rfac e k its ca n b e us ed w ith the U PS. Use only i nterfa ce kits suppli e d or appr oved by APC. An y o ther s erial int erfa ce c ab le wi ll be inco mp atib le w ith the UP S co nn ector . no rmal b yp ass Man u al by p a ss en a bl es th e user t o manu al l y [...]

  • Page 7

    . 5 C ONN ECTI NG E Q UI PME N T AN D P OWER TO THE UPS 1. Co nne ct e quip men t to the U PS ( cab les not inc luded fo r XLJ /XL T/XL TW mo de ls). 2. Avoid u si ng e xte nsi on c ords. • 3000 VA XLJ/ X LT/XLTW /X LI and 5000/60 00 V A XLJ/XLT/ XLTW models : Usin g a p ower cor d , pl u g th e UPS int o a two-p ol e, th r ee- wir e, gr oun ded [...]

  • Page 8

    6 O PERA TION Load S M ART -UPS RT F RONT D I SPLAY Ba ttery Cha rge Indicato r Description On line Th e On lin e LED illu min ates w h e n t h e U PS is d raw ing u ti lity po we r a n d pe rfo rmi ng doub le co n ve r sion to supp ly power to co n n ected e quipme n t. On Ba tte ry The U PS is supply i n g b attery powe r t o t h e co nnected e q[...]

  • Page 9

    . 7 Feature Fu nct io n Co ld S ta rt Whe n t h ere is no u ti lity pow er and t he U PS is o ff , p r ess and ho ld the b utto n to po wer u p th e UPS an d conn ect ed eq ui p m ent . The U PS w ill emi t tw o be eps . Duri ng the s ec o n d be e p, re lease t h e b utto n. Self- Test Automati c: The U PS pe rfo rms a s elf -te st auto m atic all[...]

  • Page 10

    8 U SER C ON FI GU R AB LE I TEM S N OTE : S ETT INGS ARE MAD E T HRO UG H SU PPLIED P OW ER C HUTE SOFTW ARE OP T IONAL S MA RT S LOT AC C ESSOR Y CARD S O R T ER MI NAL M ODE . F UNCTION F ACT O RY D EFAULT U SER S ELECT ABL E C HOI CE S D ESCRI PT ION A uto m atic S elf -T est Ev ery 14 da y s (336 ho urs) Ev er y 7 day s( 168 hours) , 14 day s [...]

  • Page 11

    . 9 N OTE : S ETT INGS ARE MAD E T HRO UG H SU PPLIED P OW ER C HUTE SOFTW ARE OP T IONAL S MA RT S LOT AC C ESSOR Y CARD S O R T ER MI NAL M ODE . F UNCTION F ACT O RY D EFAULT U SER S ELECT ABL E C HOI CE S D ESCRI PT ION Lo w By pass P o int - 30% o f o utpu t v o ltage sett ing - 1 5 % , - 2 0% , -2 5% , -3 0% M i ni m u m vol t a ge th at t h [...]

  • Page 12

    10 Bot h C la ss 2 an d SE LV cir cuit s mu st be i sol a t ed f r om al l prim ar y cir cu itr y . Do n ot con n ect an y ci r cui t to t h e EPO te rmi nal b lo ck unless it c an b e c onf irme d th at t he ci rcu it is Clas s 2 o r SEL V. If ci r cui t stan dar d can n ot be con fi r m ed, u se a cont a ct cl osu r e swit ch . Use on e of th e f[...]

  • Page 13

    . 11 5000/6000 VA model s: Ter minal Mo de is a me nu d riv e n i n te r fac e t hat e nable s e nhan c ed co nfig ura tion of the U P S. Conn ect th e s er ia l ca ble t o th e ser ia l p or t on th e ba ck of th e UPS. 1. Open a t ermin al pr ogr am. E xam ple: Hyper T erm ina l • From the Deskto p, go to Start => Pr ogr ams => Acces so r[...]

  • Page 14

    12 M A INTENANCE AND T RA NSPORT Replaci ng the Ba tter y Mod ule Th i s UPS h a s an ea sy to r ep l a ce, hot -s wap pa bl e ba t t er y m odu l e. Rep l a cem en t is a safe p r oced u r e, is ol a t ed fr om el ect r i ca l ha z ard s. Y ou m a y l ea ve th e UPS a n d conn ected equ i p m en t on d ur in g th e pr oced u r e. See your deal er [...]

  • Page 15

    . 13 R EPLACING B ATTERY M ODULES X Y Z [ ] ^ _  Disconnec ting th e Batter y for Tr ansport Always DI SCONNECT T H E BATTER Y(s) b efore sh i ppin g i n co mpliance w ith U.S. Department o f Tr anspo rtation (DO T) and IATA re gulati ons. The batt ery(s) m ay remain in th e UPS . 1. Sh ut d own an d d i sconn ect an y equi p m en t att a ch e[...]

  • Page 16

    14 T ROUBLESHOOT ING , S ERVI CE , A ND W A RR ANT Y I NF O R MA T IO N U se the tab le b e low to s o lve mi nor ins talla tio n a nd o pe r atio n p rob le ms. R efe r to t he APC We b s ite, ww w .apc .co m for a s si stan ce with com p l ex UPS pr oblem s . P ROBLE M AND P OSSI BL E C AU S E S OLU TI ON UPS WILL NOT TURN ON Ba t t er y n ot c o[...]

  • Page 17

    . 15 P ROBLE M AND P OSSI BL E C AU S E S OLU TI ON BY PA SS LED ILLUMINA T ES The bypass sw itch has be en turne d on manual l y or thro ugh an acc e ssory. If b yp a s s is t h e ch os en m od e of op er a t ion, ign or e t h e i l lu m in a ted L ED. If bypass i s not the c h ose n mode of o p erati on mov e the by pass swi tch on the back of th[...]

  • Page 18

    16 Ser vice If the U PS re qui r es s e rvic e d o no t retu rn it to the de ale r. Fo ll ow these ste ps: 1. Revi e w t h e pr obl em s d i s c u s s e d in th e Troub l esh ooting se ctio n o f this manu al to e lim ina te com m on pr obl e m s . 2. If th e prob lem persists, co ntact AP C Custo mer Suppo rt throu gh the APC Web si t e, ww w. a p[...]

  • Page 19

    . 17 R EGU LA TOR Y Radi o Fr equ enc y War nin gs Thi s eq uipmen t has been tes ted and fo und to compl y w i th the lim i ts f or a Class A dig ital dev ice, purs uant to par t 15 of the FC C Rules. Thes e l i mits are des igned to p rovide re a son a ble p rotect i on agains t harmf ul int erfe rence wh en the equi pment is ope rated in a comme[...]