Seagate KSD-541-P manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Seagate KSD-541-P, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Seagate KSD-541-P one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Seagate KSD-541-P. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Seagate KSD-541-P should contain:
- informations concerning technical data of Seagate KSD-541-P
- name of the manufacturer and a year of construction of the Seagate KSD-541-P item
- rules of operation, control and maintenance of the Seagate KSD-541-P item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Seagate KSD-541-P alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Seagate KSD-541-P, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Seagate service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Seagate KSD-541-P.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Seagate KSD-541-P item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    -1- Industrial 5-Port Fa st Ethernet Switche s with SFP Slot a nd option al 4 PoE PSE Ports Ba sic Model: KSD-541 PoE Model: KSD-541-P In stallation Guide DOC.080104[...]

  • Page 2

    -2- (C) 2008 KTI Networks Inc. All rights reserved. No part of this documentation may be reproduced in any form or by any means or used to make any directive work (such as translation or transformation) without permission from KTI Networks Inc. KTI Networks Inc. reserves the right to revise this documentation and to make changes in content from tim[...]

  • Page 3

    -3- The information contained in this document is subject to change without prior notice. Copyright (C) . All Rights Reserved. TRADEMARKS Ethernet is a registered trademark of Xerox Corp. W ARNING: This equi pment ha s been tested a nd found to comply with the li mits for a Cla ss A digital device, pursua nt to Part 15 of the FCC Rules. These limit[...]

  • Page 4

    -4- T a ble of Contents 1. Introduction .................................................................................................. 5 1.1 Features .................................................................................................................. .6 1.2 Product Pa nels ..........................................................[...]

  • Page 5

    -5- 1. Introduction The switches are 5-port Fa st Ethernet switches which are f eatured with four copper ports a nd one combo port. The combo port comes with one RJ-45 a nd one SFP slot. The SFP slot ca n be mounted with a fiber tra nsceiver optionally to support a fiber connection. For more coming PoE (Power Over Ethernet) a pplications, the PoE s[...]

  • Page 6

    -6- 1.1 Fe ature s  Provides 5 10/100Mbps RJ-45 a nd one 100Mbps SFP slot  All copper ports support auto-negoti ation a nd auto-MDI/MDI-X detection  Provides full wire speed forwarding  Supports IEEE 802.3x flow control for full-duplex a nd ba ckpressure for half-duplex  Provides SFP slot for optional optical fiber connection  Pro[...]

  • Page 7

    -7- 1.4 Specif ication s Copper Ports w/h PSE (P2-P5) Compli a nce IEEE 802.3 10Ba se-T , IEEE 802.3u 100Base-TX Connectors Shielded RJ-45 ja cks Pin a ssignments Auto MDI/MDI-X detection Configuration Auto-negoti ation T ra nsmission rate 10Mbps, 100Mbps Duplex support Full/Half duplex Network ca ble Cat.5 UTP Power over Ethernet IEEE 802.3af-comp[...]

  • Page 8

    -8- Power over Ethernet Function (PoE Model) PSE Pin 4,5 Positive of power voltage (T ypical 48V DC) PSE Pin 7,8 Negative of power voltage (T ypical 48V DC) Discovery PD resista nce 15K ~ 33K PD Cla ssification Cla ss 0 ~ 4 Power delivery 15.4W max. (per port) Protection Under voltage protection Over voltage protection Over current detection DC IN [...]

  • Page 9

    -9- 2. In stallation 2.1 Un pa cking The product pa ckage contains: • The switch unit • One product CD-ROM 2.2 Safety Cautions T o reduce the risk of bodily injury , electrical shock, fire, a nd da mage to the product, observe the following precautions. • Do not service any product except as explained in your system documentation. • Opening[...]

  • Page 10

    -10- 2.4 Din-Rail Mounting The steps to mount the switch on a Din-rail are: One Din-rail mounting bra cket is provided in the product pa ckage a s shown below: Install the bra cket on the bottom of the switch unit. Mount the device on a Din-rail.[...]

  • Page 11

    -11- 2.5 Pa nel Mounting One pa nel mounting bra cket is provided in the product pa ckage a s shown below: Install the bra cket on the bottom of the switch unit. The final di mension after pa nel bra cket is installed is shown below: 2.6 Applying Power The switch provides two types of power interfa ces, terminal block a nd DC power jack f or rece i[...]

  • Page 12

    -12- Using T erminal Blocks Three terminal conta cts are provided: V dc Positive ( + ) termin al V dc Negative ( - ) termin al Cha ssis ground * Working V dc for general a pplication: +6V ~ +60V DC * Working V dc for PoE a pplication : +43V ~ +54V DC (T yp. 48V) One 3P terminal plugs are provided together with the switch. The plug is shown below: P[...]

  • Page 13

    -13- 3. M a king Connection s 3.1 Ma king UTP Conne ction s The copper ports support the following connection type s a nd dista nce s: Network Cables 10BASE-T : 2-pair UTP Cat. 3,4,5 , EIA/TIA-568B 100-ohm 100BASE-TX: 2-pair / 4-pair UTP Cat. 5, EIA/TIA-568B 100-ohm Link dista nce: Up to 100 meters Auto MDI/MDI-X Function This function allows the p[...]

  • Page 14

    -14- 3.3 Ma king PoE Connection s This section describes how to make a connection between a PSE port a nd a PoE PD device. For the PoE switch model, Port 2, Port 3, Port 4 a nd Port 5 are equi pped with PoE PSE function. The ports are ena bled to deliver power together with network signal to a connected powered device vi a Cat.5 ca ble. T o make a [...]

  • Page 15

    -15- 3.4 LED Indication L ED Function State Interpretation POWER Power status O N The power is supplied to the switch. OFF The power is not supplied to the switch. LIN K/ACT Por t l ink status O N A port link is e sta blished. (No traf fic) BLIN K Port link is up a nd there is traffic. OFF Port link is down. 100M/10M Port speed status O N Speed 100[...]

  • Page 16

    -16- 4. Application s 4.1 Application s with Ba sic Switch Model The following figure illustrates a ba sic switch model connects five computers vi a Cat.5 ca ble s. The following figure illustrates a ba sic switch model connects four computers vi a Cat.5 ca bles a nd uplink to a fiber ba ckbone network.[...]

  • Page 17

    -17- 4.2 Applications with PoE Switch Model The figure below illustrates a PoE switch connects f our PoE IP camera s via Cat.5 ca ble s a nd uplinks to a fiber ba ckbone: The figure below illustrates a PoE switch connects f our PoE WLAN a ccess points vi a Cat.5 ca bles a nd uplinks to a ba ckbone:[...]

  • Page 18

    -18- The figure below illustrates a PoE switch powered by a 48V DC power a da pter connects four PoE medi a converters vi a Cat.5 ca bles a nd uplinks to a fiber ba ckbone:[...]