Go to page of
Similar user manuals
-
Receiver
Sennheiser EK 100 G3-A
28 pages -
Receiver
Sennheiser EW 512 G3-G-EU
42 pages -
Receiver
Sennheiser EW 300 IEM G3-E-EU
38 pages -
Receiver
Sennheiser SK 300 G3-G
41 pages -
Receiver
Sennheiser EW 152 G3-G-EU
40 pages -
Receiver
Sennheiser EW 322 G3-E-EU
42 pages -
Receiver
Sennheiser EW 122 G3-A-EU
40 pages -
Receiver
Sennheiser EW 165 G3
40 pages
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Sennheiser EW 335 G3-D-EU, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Sennheiser EW 335 G3-D-EU one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Sennheiser EW 335 G3-D-EU. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Sennheiser EW 335 G3-D-EU should contain:
- informations concerning technical data of Sennheiser EW 335 G3-D-EU
- name of the manufacturer and a year of construction of the Sennheiser EW 335 G3-D-EU item
- rules of operation, control and maintenance of the Sennheiser EW 335 G3-D-EU item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Sennheiser EW 335 G3-D-EU alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Sennheiser EW 335 G3-D-EU, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Sennheiser service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Sennheiser EW 335 G3-D-EU.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Sennheiser EW 335 G3-D-EU item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
3 0 0 Series Instruction manual[...]
-
Page 2
[...]
-
Page 3
Contents 1 Contents Important safe ty instructio ns ..................... ................................................ .......................................................... .............................. 2 System ....................................................... ................................................ ................. .....[...]
-
Page 4
Important safety instructions 2 Important safety instructions System • Read this instruction manual . • Keep this instruction manual. Always includ e this instruction manual w hen passing the devices and the mai ns unit on to third parties. • Heed all warnings and follow all instruc tions in this instr uction manual. • Only clean the device[...]
-
Page 5
Important safety instructions 3 • Danger due to high volumes This device is capable of producing sound pressure excee ding 85 dB(A). 85 dB(A) is the sound pressure corresponding to the maximu m permissible volu me which is by law (in some countries) allowed to aff ect your hearing for the duration of a working da y. It is used as a basis accordin[...]
-
Page 6
The ew 300 G3 evolution wire less series 4 The ew 300 G3 evolution wireless series With the ew 300 G3 evolution wireles s series, Sennheiser off ers high-quality state-of -the-art RF transmission systems with a high level of op erational reliability and ease of use. T ransmit- ters and receivers permit wireless tr ansmission with studio-quali ty so[...]
-
Page 7
Product overview 5 Product overview Overview of the EM 300 receiver A B 543.200 SKM300 ew300 G3 B. Ch: 20.24 PEAK MUTE EQ: + 12dB P -10 0 40 30 20 10 -20 -30 -40 AF RF MHz Operating elements – front panel Operating elements – rear panel Headphone output, ¼” (6.3 mm) jack socket [...]
-
Page 8
Product overview 6 Overview of the displays of the EM 300 receiver After switch-on, the receiver displays the stan dard display “ Receiver Parameters ”. For further illustrations and examples of the dif ferent standard displays, please ref er to page 25. This standard display dis plays the operating states of the receiver and pro vides the most[...]
-
Page 9
Product overview 7 Transmitter battery status Charge status: When the battery charge status is critical, “ LOW BA TT ” additionally appears on the display panel. Lock mode icon Lock mode is activated Display Meaning approx. 100% approx. 70% approx. 30% Battery icon is flashing; charge status is critical[...]
-
Page 10
Product overview 8 Overview of the SK 300 bodypack transmitter Operating elements Microphone/instrument input ( MIC / LINE ), 3.5 mm jack socket, lockabl e MUTE switc h 쐋 Socket for connection of RMS 1 external mute switch, 2.5 mm jack so cket Antenna Operation and battery status indicator, red L ED (lit = ON /flashing = LOW BATTE[...]
-
Page 11
Product overview 9 Overview of the displays of the SK 300 bodypack transmitter Af ter switch-on, the bodypack transmi tter displays the standard display “ Frequency/Name ”. For further illustrations and ex amples of the different standa rd displays, refer to page 25. The display bac klighting is automatica lly reduced af ter approx. 20 seconds.[...]
-
Page 12
Product overview 10 Overview of the SKM 300 radio microphone Operating elements Microphone head (interchangeable) Name and pick-up pattern of the microphone head (not visible here) 쐋 MIC button Body of radio microphone Battery compartment (not visible from outsid e) Display panel, ba cklit in orange Infra-red interface [...]
-
Page 13
Product overview 11 Overview of the displays of the SKM 300 radio microphone After switch-on, the radio microphone displays the standard display “ Freque ncy/Name ”. For further i llustrations and examples of the different standard dis plays, refer to page 25. The display bac klighting is automatica lly reduced af ter approx. 20 seconds. Displa[...]
-
Page 14
Putting the devices into operation 12 Putting the devices into operation EM 300 receiver Setting up the receiver on a flat surface Place the receiver on a f lat, ho rizontal surface. Please note that the device feet ca n leave stains on delicate surfaces. Fitting the device feet Clean the base of the rece iver where you want to f ix the device [...]
-
Page 15
Putting the devices into operation 13 Connecting an amplifier/mixing console The receiver’s ¼” (6.3 mm) jack socket and the XLR-3M socket are connected in parallel. Use a suitable cable to connect the amplif ier and/or the mixing console to the ¼” (6.3 mm) jack socket and/or the XLR-3M socket . Via the operating menu[...]
-
Page 16
Putting the devices into operation 14 SK 300 bodypack transmitter Inserting the batteries/accupack For powering the bodypack transmitter, you can e ither use two 1.5 V AA size batte ries or the rechargeable Sennheiser BA 2015 accupack. Push the two catches in the direction of the arrows and open the battery compart- ment cover . Ins[...]
-
Page 17
Putting the devices into operation 15 Attaching and positioning th e corresponding microphones ME 2/ME 4 Use the microphone clip , to attach the microphone to clothing (e.g. tie, lapel). The ME 2 clip-on microphone (shown on the ri ght in the diagram) has an omni-directional pick-up pattern. It is therefore not necessary to position it prec[...]
-
Page 18
Putting the devices into operation 16 Unscrew the lower part of the radio micr ophone from the radio microphone’s body by turning it counterclockwis e. Slide back the lower part of the ra dio microphone as far as it will go. Open the battery compartment cover . Insert the batteries or the BA 2015 accupack as shown on the b[...]
-
Page 19
Using the device s 17 Screw the desired microphone he ad to the radio microphone. Put the radio microphone back into operation. Changing the color-co ded protection ring The color-coded protection ring prevents the multi-function switch from accidental operation. Protection rings in different colors are availabl e as acce ssories. T[...]
-
Page 20
Using the devices 18 Switching the devices on/off EM 300 receiver T o switch the receiver on : T o switch the receiver to standby mode : If necessary, deactivate the lock mode (see page 21). To completely s witch the rece iver off : Disconnect the receiv er from the mains by unplugging the mains unit from the wall socket. SK 300 bodypack tr[...]
-
Page 21
Using the device s 19 T o switch the bodypack transmitter off : If necess ary, deactivate the lock mode (see page 21). T o switch the bo dypack transmitter on and to deactivate the RF signal on switch-on (offline operatio n): To activate the RF signal : Briefly press the ON / OFF button . The bodypack transmitter transmits an RF signal.[...]
-
Page 22
Using the devices 20 SKM 300 radio microphone T o swi tch the radio microphone on (online operation): T o swi tch the radio microphone off : If necessary, deactivate the lock mode (see page 21). T o switch the radio micro phone on and to deactivate the RF signal on switch-on (offline operation): Briefly press the ON / OFF butto n . The [...]
-
Page 23
Using the device s 21 To activate the RF signal : Synchronizing a transmitter with the receiver You can synchronize a s uitable transmitter of the ew 300 G3 series wi th the receiver. During synchronization, the following parameters are transferred to the transmitter: T o transfer the parameters: Switch the transmitter and the receiver on. [...]
-
Page 24
Using the devices 22 SK 300 SKM 300 How you are using the devic es determines ho w long the lock mode remain s deactivated: Prior to this, the lock mode icon flashe s, indi cating that the lock mo de is being activated. Muting the audio signal or deactivating the RF signal EM 300 To mute the audio sign al: To unmute the audio signal: Press t he[...]
-
Page 25
Using the device s 23 SK 300 The MUTE switch allows you to mute the audio signal or to deactivate the RF signal. Via the “ Mute Mode ” menu item, you can set the desired function of the MUTE swi tch : The “ Push to mute ” and “ Push to talk ” menu items are only available in conjunction with the RMS 1 external mute switch (optio[...]
-
Page 26
Using the devices 24 SKM 300 The MIC button 쐋 allows you to mut e the audio signal or to deactivate the RF signal. Via the “ Mute Mode ” menu item, you can set the desired function of the MIC button 쐋 : From the “ Mute Mode ” menu item, select the desi red setting (see page 25). Exit the operating menu. Brief ly press the MI[...]
-
Page 27
Overview of the operating menu s 25 Selecting a standard display EM 300 SK 300 and SKM 300 T o sel ect a standard display: You can select the following standard displays: “ Frequency/Name ”, “ Channel/Frequency ”, “ Channel/ Name ”. Overview of the operating menus Press the jog dial to sel ect a standard display: Contents of the dis[...]
-
Page 28
Overview of the operating menus 26 EM 300 When one of the standard displa ys is shown on the display panel, you can get into the main menu by pressing the jog dial . The extend ed menu “ Advanced Menu ” and the submenus can be accessed via the corresponding menu items. Squelch Easy Setup Frequency Preset Name AF Out Equalizer AutoLock Advan[...]
-
Page 29
Overview of the operating menu s 27 Equalizer Changes the frequency response of the output signal Auto Lock Activates/deactivates the automatic lock mode Advanced Calls up the extended menu “ Advanced Menu ” Exit Exits the operating menu and return s to the current standard display “Easy Setup” Reset List Releases all locked frequency prese[...]
-
Page 30
Overview of the operating menus 28 SK 300 and SKM 300 Main menu “Menu” Sensitivity Frequency Preset Name Auto Lock Advanced Exit Tune Mute Mode RF Power Pilot T one LCD-Contrast Reset Software Revision Exit Extended menu “Advanced Menu” Display Meanin g Main menu “Menu” Sensitivity Adjusts the sen sitivity “ AF ” Frequency Preset* C[...]
-
Page 31
Cleaning the devices 29 Cleaning the devices EM 300 Before cleaning, disc onnect the device from the mains. Use a slightly da mp cloth to clean the re ceiver from time to time . Do not use any solvents or cleansing agents. SK 300 Use a slightly da mp cloth to clean the bodypa ck transmitter from time to time. Do not use any solvents or [...]
-
Page 32
Cleaning the devices 30 If a problem occurs ... EM 300 Problem Possible cause Possible solution Receiver cannot be oper- ated, “ Locked ” appears on the display panel Lock mode is activated Deactivate the lock mode (see page 21). No operation indication No mains connecti on Check the co nnections of the mains unit. No RF signal Transmitter and [...]
-
Page 33
Cleaning the devices 31 SK 300 and SKM 300 If a problem occurs that is not listed in the above table or if the problem cannot be solved with the proposed solutions, please contact your local Sennheiser partner for assistance. T o find a S ennheiser pa rtner in your country, searc h at www.sennheiser.com under “Service & Support”. Problem Po[...]
-
Page 34
Specifications 32 Specifications EM 300 RF characteristics Modulation wideband FM Receiving frequency ranges 516– 558, 566–608, 626–668, 734–776, 780–822, 823–865 MHz (A to E, G, see pag e 4) Receiving frequencies 1,680 frequencie s, tuneable in steps of 25 k Hz 20 frequency banks, each with up to 24 factory-preset channels, intermodula[...]
-
Page 35
Specificati ons 33 In compliance with (EM) Approved by In compliance with Certified by cCSAus KL, 6 0065, CSA. SK 300 and SKM 300 Europe: USA: EMC EN 301489-1/-9 Radio EN 300422-1/-2 Safety EN 60065 47 CFR 15 subpart B Canada: Industry Canada RSS 210, IC: 2099A-G3SKMEM Mains unit Input volt age 100 to 240 V~, 50 /60 Hz Power/current consumption max[...]
-
Page 36
Specifications 34 In compliance with (SK and SKM) Approved by (SK) Approved by (SKM) AF characteristics Compander syst em Sennheiser HDX AF frequency response SK microphone: 80–18,000 Hz line: 25–18,000 Hz SKM 80–18,000 Hz S/N ratio (1 mV , peak deviation) ≥ 115 dBA THD ≤ 0.9% Max. input voltage (SK) microphone/line 3 V rms Input impedanc[...]
-
Page 37
Specificati ons 35 Microphones (SK 300) Microphone heads (SKM 300) Polar diagrams and frequency response cu rves of the microphone heads (SKM 300) ME 2 ME 3 ME 4 Micro phone type cond enser condenser condenser Sensitivity 20 mV/P a 1.6 mV/Pa 40 mV/Pa Pick-up pattern omni-directional cardioid cardioid Max. SPL 130 dB SPL 150 dB SPL 120 dB SPL MMD 83[...]
-
Page 38
Manufacturer Declarations 36 Manufacturer Declarations W arranty Sennheiser electro nic GmbH & Co. KG give s a warranty of 24 months on this product. For the current warranty condit ions, please visit our we b site at www.sennheiser.com or contact your Sennheiser partner. In compliance with the following requirement s • RoHS Directive (2002/9[...]
-
Page 39
Manufact urer Declarat ions 37 Statements regarding FCC and Industry Canada These devices comply with P art 15 of the FC C Rules and with RSS-210 of Industry Canada. Operation is subject to the following two cond itions: (1) these devices may not cause harmful interference, and (2) these devices must accept any interference receiv ed, includin g in[...]
-
Page 40
[...]
-
Page 41
[...]
-
Page 42
Sennheiser electronic GmbH & Co. KG Am Labor 1, 30900 W edemark, Germany www.sennheiser.com Printed in Germany Publ. 01/09 52966 1 /A01[...]