Sennheiser SK 50_250 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Sennheiser SK 50_250, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Sennheiser SK 50_250 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Sennheiser SK 50_250. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Sennheiser SK 50_250 should contain:
- informations concerning technical data of Sennheiser SK 50_250
- name of the manufacturer and a year of construction of the Sennheiser SK 50_250 item
- rules of operation, control and maintenance of the Sennheiser SK 50_250 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Sennheiser SK 50_250 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Sennheiser SK 50_250, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Sennheiser service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Sennheiser SK 50_250.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Sennheiser SK 50_250 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Bedienungsanleitung Instructions for use Notice d‘emploi Istruzioni per l‘u so Instrucciones para el uso Gebruiksaanwi jzing Bruksanvisning SK 50 SK 250 SK 50_250 Titel.fm Seite 1 Mon tag, 4. April 2005 11:09 11[...]

  • Page 2

    Gebrauchsanleitung .................................. 3 Instructions for use .................................. 17 Instructions pour l’usage .................... .... 31 Istruzioni per l’uso ........................ ........... 45 Mode de empleo ................................... .... 59 Gebruiksaanwijzing ...................... ........... 73[...]

  • Page 3

    17 INSTRUCTIONS FOR USE MIKROPORT BODY-PACK TRANSMITTER SK 50 SK 250[...]

  • Page 4

    18 CONTENTS 1. BRIEF DESCRIPTION 19 2. CONTROLS AND CONNECTIONS 20 3. MICROPHONE SELECTION 21 4. USING FOR THE FIRST TIME 21 4.1. B 50 / B 250 QUICK-CHANGE ENERGY PACK 21 4.2. BA 50 / BA 250 QUICK-CHANGE ENERGY PACK 23 4.3. POSSIBLE COMBINATIONS OF TRANSMITTERS WITH THE QUICK-CHANGE ENERGY PACK 24 5. CHANNEL SELECTION 24 6. SWITCHING ON 24 7. SENSI[...]

  • Page 5

    19 1. BRIEF DESCRIPTION MODELS FREQUENCY RANGE SWITCHING BAND WIDTH CHANNELS SK 50 UHF 450 bis 960 MHz 24 MHz 16 SK 250 UHF 450 bis 960 MHz 24 MHz 16 SK 50 VHF (1) 138 bis 160 MHz 22 MHz 16 SK 50 VHF (2) 153 bis 181 MHz 28 MHz 16 SK 50 VHF (3) 174 bis 202 MHz 28 MHz 16 SK 50 VHF (4) 195 bis 223 MHz 28 MHz 16 SK 50 VHF (5) 223 bis 260 MHz 37 MHz 16 [...]

  • Page 6

    20 2. CONTROLS AND CONNECTIONS 1 2 3 7 4 5 6 1 ANTENNA SOCKET 2 CHANNEL SELECTION SWITCH 3 OPERATING TIME DISPLAY 4 ON / OFF SWITCH 5 OPERATING / PEAK DEVIATION INDICATOR 6 SENSITIVITY SELECTOR SWITCH FOR MICROPHONE INPUT 7 MICROPHONE INPUT[...]

  • Page 7

    21 3. MICROPHONE SELECTON The MKE 2-4, MKE 102-4 (omnidirectional polar pattern) and MKE 40-4 (cardioid polar pattern) Lavalier chlip-on microphones are available. They are equipped with a special Lemo plug. The plug is disconnected by unscrewing the threaded collar. The voltage necessary to operate these microphones is available at the microphone [...]

  • Page 8

    22 FIG. 2 QUICK-CHANGE ENERGY PACK B 50 QUICK-CHANGE ENERGY PACK B 250 + + + + + CLOSE COVER NOTE: ALKALINE-MANGANESE BATTERIES OF THE "MIGNON" LRC AA TYPE ARE TO BE USED EXCLUSIVELY. PERFECT FUNCTIONING OFTHE TRANSMITTER IS GUARANTEED ONLY WITH THIS TYPE OFBATTERY. FIG. 3[...]

  • Page 9

    23 4.2. BA 50 / BA 250 QUICK-CHANGE ENERGY PACK The LCD display on the front side of the energy pack (Fig. 4) servers as a battery control display. FIG. 5 RELEASING THE QUICK-CHANGE ENERGIE PACK Squeeze the catch with the thumb and index finger, and separate the transmitter from the quick-change energy pack. To attach the quick-change energy pack, [...]

  • Page 10

    24 4.3. POSSIBLE COMBINATIONS OF TRANSMITTERS WITH THE QUICK-CHANGE ENERGY PACK FIG. 6 SK 50-UHF SK 50-UHF SK 50-UHF SK 50-UHF SK 250-UHF SK 250-UHF SK 250-UHF SK 250-UHF B 50 B 250 BA 250 BA 50 B 50 B 250 BA 250 BA 50 SK 50 SK 250 The SK 250 / B 50 and SK 250 / BA 50 combinations are not possible because the power of the battery / rechargeable bat[...]

  • Page 11

    25 7. SENSITIVITY SELECTOR SWITCH The sensitivity selector switch 6 can be used to adapt the gain of the microphone input in 8 steps to the level of the sound expected. This setting is to be made in combination with a receiver which has a peak indicator available, such as the EM 1046. The sensitivity is set correctly when the "peak" indic[...]

  • Page 12

    26 FIG, 7 9. LICENSING REGULATIONS The type plate contains the channel data and the transmit frequency data as well as the BZT approval, which you require for your application for the licence from the Post Office. It is located on the underside of the device. Note: The transmitter can also be attached so that the cable and antenna point downwards.[...]

  • Page 13

    27 10. TECHNICAL DATA SK 50 UHF / SK 250 UHF Transmit frequencies 16 Frequency range 450 - 960 MHz Switching band width 24 MHz Frequency stability ± 5 ppm Spurious and emmissions < 4 nW Modulation FM Nominal / peak deviation ± 40 kHz / ± 56 kHz Compander Sennheiser HiDyn plus Input sensitivity for peak deviation 13.2 mV - 1.55 V 8-position sw[...]

  • Page 14

    28 11. TECHNICAL DATA SK 50 VHF Transmit frequencies 16 Frequency range SK 50 VHF (1) 138 ... 160 MHz SK 50 VHF (2) 153 ... 181 MHz SK 50 VHF (3) 174 ... 202 MHz SK 50 VHF (4) 195 ... 223 MHz SK 50 VHF (5) 223 ... 260 MHz Switching band width SK 50 VHF (1) 22 MHz SK 50 VHF (2) 28 MHz SK 50 VHF (3) 28 MHz SK 50 VHF (4) 28 MHz SK 50 VHF (5) 37 MHz Fr[...]

  • Page 15

    29 11. TECHNICAL DATA SK 250 VHF Transmit frequencies 16 Frequency range SK 250 VHF (1) 138 ... 170 MHz SK 250 VHF (2) 170 ... 225 MHz SK 250 VHF (3) 210 ... 260 MHz Switching band width SK 250 VHF (1) 38 MHz SK 250 VHF (2) 55 MHz SK 250 VHF (3) 50 MHz Frequency stability ± 10 ppm Spurious and emmissions < 4 nW Modulation FM Nominal / peak devi[...]

  • Page 16

    104 KONFORMITÄTSERKLÄRUNG Sennheiser electronic GmbH & Co. KG, Am Labor 1, D-30900 Wedemark erklären, daß dieses Gerät den einschlägigen Anforderungen der EG-Richt- linie 89/336/EWG entspricht. Zur sachgemäßen Umsetzung der in den EG-Richtlinien genannten Anforde- rungen wurden folgende Normen herangezogen: ETS 300 445 ETS 300 422 Bemer[...]

  • Page 17

    105 CERTIFICATO DI CONFORMITÁ Sennheiser electronic GmbH & Co. KG, Am Labor 1, D-30900 Wedemark dichiariamo che questo apparecchio risponde alla normativa 89/336/EWG. Per un’appropriato risconto nell’ambito della normativa CEE sono state consultate le seguenti normative: ETS 300 445 ETS 300 422 Nota: Prima della messa in funzione seguite l[...]

  • Page 18

    106 Sk 50 letzte Seiten 04.02.2002, 11:10 Uhr 106[...]

  • Page 19

    107 Sk 50 letzte Seiten 04.02.2002, 11:10 Uhr 107[...]

  • Page 20

    Sennheiser ele ctronic GmbH & Co. KG 30900 Wedemark, Germany Phone +49 (5130) 600 0 Fax +49 (5130) 600 300 www.sennheiser.com Printed in Germany Publ. 04/05 48208/A07 SK 50_250 Titel.fm Seite 2 Mon tag, 4. April 2005 11:09 11[...]