Shure Conference Phone manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Shure Conference Phone, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Shure Conference Phone one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Shure Conference Phone. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Shure Conference Phone should contain:
- informations concerning technical data of Shure Conference Phone
- name of the manufacturer and a year of construction of the Shure Conference Phone item
- rules of operation, control and maintenance of the Shure Conference Phone item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Shure Conference Phone alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Shure Conference Phone, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Shure service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Shure Conference Phone.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Shure Conference Phone item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Model User Guide User Guide ©2006, Shure Incorporated 27A8781 (Rev. 1) TM[...]

  • Page 2

    English 1. READ these instructions. 2. KEEP these instructions. 3. HEED all warnings. 4. FOLL OW all instructions. 5. DO NOT use this apparatus near water . 6. CLEAN ONL Y with dry cloth. 7. DO NOT block any ventilation openings. Install in accordance with the manufacturer’s instructions. 8. Do not install near any heat sources such as radiators,[...]

  • Page 3

    1 Introduction The Shure’s Conference ONE ™i Discussion System is extremely easy to install and use. It was developed for use at conferences, meetings, platform discussions and other comparable applications. Due to its integrated loudspeakers, the Conference ONE ™i Discussion System also functions as a completely self-contained public address[...]

  • Page 4

    2 Description 2.1 P ower Supply Unit C1-PS 60i The power supply unit C1-PS 60i supplies the consoles with power and serves as an interface to external devices. Front view 2 3 3 7 4 1 5 6 2 Daisy chain socket Minicon socket connecting the consoles via bus cables. Audio output The ON/OFF button activates the audio output on the rear of the unit. The [...]

  • Page 5

    IntelliMix ® Link input Socket for connection of a Shure SCM series automatic mixer . Please note that the audio signal only flows from the SCM series mixers into the Conference ONE ™ Discussion System and not from the Discussion System into the connected SCM series mixers. 7 2 4 Power socket Socket with integrated fuse. Remote socket SUB-D 9 so[...]

  • Page 6

    6 7 5 2.2 Delegate Console C1-Di 2 5 2 1 4 3 Microphone arm Fold-out arm with telescopic microphone. Headphone volume control Adjusts the headphone volume. Lightring Illuminates when the microphone of the console is active. Blinks in manual mode if the PTT button is pressed and the maximum number of microphones is already active. Daisy chain socket[...]

  • Page 7

    2 6 2.3 Chairman Console C1-Ci 2 1 5 6 8 9 4 3 7 Microphone arm Fold-out arm with telescopic microphone. CANCEL button Pressing this button switches off all active microphones in the system except the microphone of the chairman console. Lightring Illuminates when the microphone of the console is active. SELECT button Press to select functions on th[...]

  • Page 8

    3 7 Headphone volume control Adjusts the headphone volume. Headphone socket 1/8” stereo headphone socket. The console speaker switches off when you connect headphones. CAUTION : Use only stereo plugs! Daisy chain sockets Minicon socket for connection and through-connection of the console bus. The sockets are interchangeable; either one may be use[...]

  • Page 9

    3 8 3.2 P ossible Configurations For small systems, up to 15 consoles can be connected directly to the Minicon socket on the front of the power supply unit. The bus cable is connected from each console to the next. Larger systems with more than 15 consoles or in systems where the first console is more than 10 meters away from the power supply unit [...]

  • Page 10

    4 9 4 System Settings All adjustments to the settings of the conference system are made on the chairman console. The controls located on the power supply unit adjust signal input and output for external devices. 4.1 P ower Supply Unit The slide switch beside the input socket on the rear of the power supply unit sets the sensitivity of the audio inp[...]

  • Page 11

    4 10 4.2 Chairman Console The system is configured from the chairman's console with the aid of the LCD and the three buttons below it: SELECT ,  and  . 4.2.1 Status P age In normal operating mode, the display shows the status page with the current settings. The display always returns automatically to this status page if there is no user [...]

  • Page 12

    4 11 Use the Mode menu item to select either the Manual or Automatic (Auto) operating mode. In manual mode, you can use the Limit menu item to specify the maximum number of microphones that can be activated simultaneously in addition to the chairman console. If the Limit is set to 1, the timer is displayed. Press  or  buttons to change the va[...]

  • Page 13

    4 12 4.3 T est Mode Activate test mode by pressing and holding both of the  and  buttons for approximately three seconds. The installed software version appears in the display and the lighted rings on all delegate consoles illuminate in order to permit simple detection of any cable breakage or defective consoles. Press the SELECT button to re[...]

  • Page 14

    English 5 AEC / T elco Audio Interface This interface provides a dedicated termination to connect the discussion system directly to most external telephone hybrids or videoconference codecs, enabling users of the system to communicate with remote parties. When used in conjunction with a telephone hybrid, the Conference ONE ™ discussion system can[...]

  • Page 15

    English 6 System Operation The Conference ONE ™i Discussion System can be operated in either of the two operating modes described below . 6.1 Manual Mode In manual mode, each console microphone is activated by simply pressing the PTT button and deactivated by pressing this button again. However , the number of simultaneously active microphones is[...]

  • Page 16

    English 6 15 6.3 Operating Instructions T o set the volume of the system: 1. Press  or  button to change the volume 2. Press SELECT to return to the Status P age T o select Operating mode: 1. Press SELECT to access the Setup menu 2. Press  or  button until the Mode menu is underlined in the display 3. Press SELECT to access the Mode men[...]

  • Page 17

    English 7 16 Green Power LED is off • Is the power cable plugged in? • Is the power switch set to ON (I)? • Check the main fuse in the power socket. Red Protect LED illuminates • Check that the maximum permissible number of consoles has not been exceeded (60). • Disconnect all consoles and cables. If the LED still illuminates, send the po[...]

  • Page 18

    Output Clipping Level Impendance English 8 17 8 T echnical Data P ower supply unit C1-PS 60i Mains voltage C1-PS 60i A: 120 V AC, 50/60 Hz C1-PS 60i J: 100 V AC, 50/60 Hz C1-PS 60i E, C1-PS 60i UK : 220 - 240 V AC, 50/60 Hz Power rating: 330 VA Primary Fuses C1-PS 60i A: T4A C1-PS 60i J: T5A C1-PS 60i E, C1-PS 60i UK : T2A Secondary Fuses: 2 x T8A [...]

  • Page 19

    Consoles Power rating Delegate console C1-Di: 1,7 W Chairman console C1-Ci: 5,3 W Microphone Microphone type: Electret-condenser (Microflex ® ) Directional characteristic: Supercardioid Headphone output Output impedance: 4 Ohm Socket: 1/8” stereo jack socket P erformance Microphone to audio output Frequency range: 100 Hz – 15 kHz Distortion fa[...]

  • Page 20

    &HUWLILFDWLRQ  /,67('WR  / 8 F   Q R L W L G (  G Q      /,67('WR8/  / 8 $  L    6 3   &  O H G R 0 &$1&6$ ( $XWKRUL]HG XQGHU WKH 9 HULILFDWLRQ SURYLVLRQ RI )&& 3DUW [...]

  • Page 21

    English Pin Signal Cable Color Code 1 Audio 1 black 2 Control 2 blue 3 -24 V gray 4 GND brown 5 GND purple 6 GND red/gray 7 GND red 8 +24 V pink 9 Control 3 yellow 10 Control 1 green 11 Mic Bus white 12 Mode red/blue Pin Signal 1 n.c. 2 TXD 3 RXD 4 n.c. 5 GND 6 n.c. 7 n.c. 8 n.c. 9 n.c. 9 20 9 Appendix A – Connector Pin Assignments 912 8 10 12 3 [...]

  • Page 22

    Pin Signal Cable color code 1 GND Shield 2 GND Shield 3 +24 V red 4 - 24 V blue 5 Mode white/orange 6 Control 2 brown 7 Audio white/green 8 MicBus white/blue 9 Control 3 white/red 10 Control 1 yellow 11 +24 V white/brown 12 - 24 V orange 13 GND n.c. 14 GND Shield 15 +24 V purple 16 -24 V gray 17 GND n.c. 18 GND black 19 Audio white/green 20 Mic Bus[...]

  • Page 23

    Switch input off Switch input on Switch output off Switch output on 01 h to 1E h -- -- 00 h 01 h T oggle input on/off switch -- T oggle output on/off switch -- 00 h 01 h English 22 9 Appendix B - AMX/Creston 10 General command structure: F0 h <command byte h > <data byte h >F 7 h There are three types of commands: Set , Get and Report :[...]

  • Page 24

    English 21 h 01 h to 1E h 22 h 01 h to 1E h 23 h 24 h 25 h XX h 10 23 Get commands Report from power supply 00 h 01 h 00 h 01 h Report the input level, 01 h =mute 1E h =highest level Report the output level, 01 h =mute 1E h =highest level Report: input switch is off Report: input switch is on Report: output switch is off Report: output switch is on[...]

  • Page 25

    Shure Europe GmbH Wannenäcker Str . 28 D-74078 Heilbronn Phone: 49-7131-72140 Fax: 49-7131-721414 E-mail: sales@shure.de Unit 301, 3 Floor , Citicorp Centre, 18, Whitfield Road, Causeway Bay , Hong Kong Phone: 852-2893-4290 Fax: 852-2893-4055 E-mail: sales@shure.com.hk rd Shure Incorporated 5800 W . T ouhy Avenue Niles, IL 60714-4608, U .S.A. Phon[...]