Go to page of
Similar user manuals
-
Stereo Amplifier
Shure RK183PK
1 pages 0.07 mb -
Stereo Amplifier
Shure FP22
5 pages 0.07 mb -
Stereo Amplifier
Shure FP16A
6 pages 0.89 mb -
Stereo Amplifier
Shure RK183PKW
1 pages 0.07 mb -
Stereo Amplifier
Shure MX1BP
12 pages 0.34 mb -
Stereo Amplifier
Shure FP23
4 pages 0.06 mb -
Stereo Amplifier
Shure HTSSOSPA
8 pages 5.49 mb -
Stereo Amplifier
Shure SR105
34 pages 4.99 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Shure FP16A, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Shure FP16A one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Shure FP16A. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Shure FP16A should contain:
- informations concerning technical data of Shure FP16A
- name of the manufacturer and a year of construction of the Shure FP16A item
- rules of operation, control and maintenance of the Shure FP16A item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Shure FP16A alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Shure FP16A, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Shure service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Shure FP16A.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Shure FP16A item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
Model FP16A Distribution Amp lifier User Guide © 2004, Shure Incorporated 27A8725 (Rev . 3) Printed in U.S. A. GENERAL DESCRIPTION The FP16A i s a 1-input, 6- outpu t, compact, self-c ontained aud io distri bution amplifier for routin g multiple audio signa l feeds without incurr ing los s, disto rtion, hu m or nois e. The i ntellige nt des ign, r[...]
-
Page 2
2 SPECIFICATIONS Freque ncy Response (ref 1 kHz) 30 to 20,000 Hz, ± 2 dB Voltage G a in (at 1 kHz ) Inputs *Dependent on input control setti n g Outputs Noise Equivalent Input Noise: -129 dBV (low-impedance mi crophone, 150 Ohms, 300 to 20,000 Hz) into 600 ohm load at full gain Equivalent Input Hum and Noise: -127 dBV (low-imped ance micro- phone,[...]
-
Page 3
3 INSTALLATION AND OPERATION Battery Operation In addition to 120 or 240 V AC operation, the FP16A ca n be operated from an i nternal battery pack. Current d rain is typ- ically 22 mA at +4 dB m output level. Ba ttery operat ion is rec- ommended for remo te, on-lo cation op eration, a nd as an emergenc y back up sour ce in case of A C power failur [...]
-
Page 4
4 REPLACEMENT PARTS LIST REFERENCE DESIGNA TION DESCRIPTION SHURE P ART (COMME RCIAL AL TERNA TIVE) C101 Capacitor , Electrolytic, 47 µ , 35V Shure 60101FT (S pra gue 503D476F035ND) C104, C107, C130 Capacitor , Electrolytic, 22 µ F , 35V Shure 60104F T (S prague 502D226G050CE1C) C105, C108, C1 1 1, C1 14, C1 17, C120, C123 Capacitor , Electrolyti[...]
-
Page 5
11[...]
-
Page 6
SHURE Incorpor ated We b Address: http://ww w.shure.co m 5800 W. Touhy Avenue, N iles, IL 6 0714-460 8, U.S.A. In U.S.A ., Phone: 1-8 47-600- 2000 Fax: 1-847-600- 1212 In Europe, Phone: 49 -7131-721 40 Fax: 49- 7131-72 1414 In Asia, P hone: 1-852- 2893-4 290 Fax: 1-85 2-2893- 4055 Inter nationa l Fax: 1-84 7-600 -6446[...]