Siemens C79000-Z7076-C552-01 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Siemens C79000-Z7076-C552-01, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Siemens C79000-Z7076-C552-01 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Siemens C79000-Z7076-C552-01. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Siemens C79000-Z7076-C552-01 should contain:
- informations concerning technical data of Siemens C79000-Z7076-C552-01
- name of the manufacturer and a year of construction of the Siemens C79000-Z7076-C552-01 item
- rules of operation, control and maintenance of the Siemens C79000-Z7076-C552-01 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Siemens C79000-Z7076-C552-01 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Siemens C79000-Z7076-C552-01, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Siemens service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Siemens C79000-Z7076-C552-01.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Siemens C79000-Z7076-C552-01 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Copyright 1998 by Siemens AG C79000-Z7076-C552-01 Supplement to the STEP 7 User Manual V4.0 New Functions in V ersion 4.02 Contents Page 1 Overview 2 2 Creating and Editing Projects 3 3 Configuring Hardware 4 4 Configuring Networks and Connections 10 5 Using Upper and Lower Case for Shared and Local Symbols 1 1 6 Creating User Programs 14 7 Display[...]

  • Page 2

    New Functions in V ersion V4.02 2 Supplement to the STEP 7 User Manual V4.0 C79000-Z7076-C552-01 1 Overview New and Modified Functions in STEP 7 V ersion 4.02 The information in this supplement will familiarize you with the additional functions of STEP 7, version 4.02 in a short and concise manner . Y ou should already be familiar with version 4.01[...]

  • Page 3

    New Functions in V ersion V4.02 3 Supplement to the STEP 7 User Manual V4.0 C79000-Z7076-C552-01 2 Creating and Editing Projects New Function: Password Protection for Access to Programmable Controllers With the aid of password protection you can:  Protect the user program and its data in the CPU against unwanted changes (write protection),  P[...]

  • Page 4

    New Functions in V ersion V4.02 4 Supplement to the STEP 7 User Manual V4.0 C79000-Z7076-C552-01 3 Configuring Hardware New CPU Parameters There are many new components in version 4.02; for example, racks, C7 control systems, or CPUs in the hardware catalog. It is not possible to list all the updates or changes within the scope of this supplement; [...]

  • Page 5

    New Functions in V ersion V4.02 5 Supplement to the STEP 7 User Manual V4.0 C79000-Z7076-C552-01 Improved Display and Print Functions The changes to the display and print functions are listed below in detail, with a brief description of how each function can be used. Function Comment Object names, for example, the description of a CPU can be stored[...]

  • Page 6

    New Functions in V ersion V4.02 6 Supplement to the STEP 7 User Manual V4.0 C79000-Z7076-C552-01 Configuring the ET 200X (BM 147/CPU) as a DP Slave The BM 147/CPU basic submodule is configured as an intelligent DP slave. In contrast to other intelligent DP slaves, the basic submodule can be found under “PROFIBUS DP/ET 200X/BM 147/CPU” in the ?[...]

  • Page 7

    New Functions in V ersion V4.02 7 Supplement to the STEP 7 User Manual V4.0 C79000-Z7076-C552-01 Configuring the DP/P A Link The DP/P A link is a DP slave which for its part (acting as a kind of “master”) “opens” a PROFIBUS P A for connecting PROFIBUS P A devices. The PROFIBUS P A must be running at a transmission rate of 45.45 Kbps when yo[...]

  • Page 8

    New Functions in V ersion V4.02 8 Supplement to the STEP 7 User Manual V4.0 C79000-Z7076-C552-01 Configuring Software Redundancy The configuration of a “warm standby” system consists of:  T wo S7 stations with one PROFIBUS-DP master interface each (each of these interfaces forms its own subnet).  One or more ET 200M devices with IM 153-3 [...]

  • Page 9

    New Functions in V ersion V4.02 9 Supplement to the STEP 7 User Manual V4.0 C79000-Z7076-C552-01 Creating a Catalog Profile If the hardware catalog supplied with STEP 7 is too large or too dif ficult for you to use, you can create your “own” catalog. In this way different catalog profiles are produced. The basis for each new catalog profile is [...]

  • Page 10

    New Functions in V ersion V4.02 10 Supplement to the STEP 7 User Manual V4.0 C79000-Z7076-C552-01 4 Configuring Networks and Connections Configuring Connections while Configuring a Network The application for configuring networks can also be used to configure connections. T o configure a connection, simply select a module to which connection data c[...]

  • Page 11

    New Functions in V ersion V4.02 11 Supplement to the STEP 7 User Manual V4.0 C79000-Z7076-C552-01 Connecting an S7-200 to the Multipoint Interface If you wish to connect an S7-200 to the MPI subnet (in addition to programming devices, operating panels, or S7-300/400s), you must select a transmission rate of 19.2 Kbps in the properties dialog box fo[...]

  • Page 12

    New Functions in V ersion V4.02 12 Supplement to the STEP 7 User Manual V4.0 C79000-Z7076-C552-01 Effects on Existing Programs If you have been using this criterion to distinguish between different symbols, you may experience difficulties with the new definition if:  Symbols dif fer from one another only in their use of upper and lower case char[...]

  • Page 13

    New Functions in V ersion V4.02 13 Supplement to the STEP 7 User Manual V4.0 C79000-Z7076-C552-01 Parameters which Differ from One Another Only in their Use of Upper and Lower Case Characters Conflict: Source files containing such interfaces can no longer be compiled without errors. Blocks with such interfaces can be opened, but access to the secon[...]

  • Page 14

    New Functions in V ersion V4.02 14 Supplement to the STEP 7 User Manual V4.0 C79000-Z7076-C552-01 6 Creating User Programs Operation New menu command Edit  Select All : The effect depends on the context in which the command is used (see online help). Selected networks can be cut, deleted, and copied, as well as inserted into blocks of the same l[...]

  • Page 15

    New Functions in V ersion V4.02 15 Supplement to the STEP 7 User Manual V4.0 C79000-Z7076-C552-01 7 Displaying Reference Data New Menu Command: Filter and Display Y ou can use this menu command to call up the reference data and to set the filters before the reference data are displayed. If a program is very large, you can use filters to limit the q[...]

  • Page 16

    New Functions in V ersion V4.02 16 Supplement to the STEP 7 User Manual V4.0 C79000-Z7076-C552-01 9 Debugging User Programs Programming LAD/STL/FBD S7 Blocks: T est Environment for Debugging in Program Status The execution of test functions is dependent on the mode of operation set (process operation or test operation). The mode determines whether [...]

  • Page 17

    New Functions in V ersion V4.02 17 Supplement to the STEP 7 User Manual V4.0 C79000-Z7076-C552-01 New Functions: Forcing with S7-300 Modules The following table provides an overview of the functions and summarizes the differences between forcing and modifying. Feature / Function Force Modify with S7-400 with S7-300 Bit memory (M) yes no yes T imers[...]

  • Page 18

    New Functions in V ersion V4.02 18 Supplement to the STEP 7 User Manual V4.0 C79000-Z7076-C552-01 10 Diagnosing Hardware New Function: Diagnosing Hardware – Quick View In the SIMA TIC Manager you can specify which of the following options should be displayed when you call up diagnosing hardware:  Short information (“Diagnosing Hardware - Qui[...]

  • Page 19

    New Functions in V ersion V4.02 19 Supplement to the STEP 7 User Manual V4.0 C79000-Z7076-C552-01 12 Printing Improved Print Functions in the SIMA TIC Manager Y ou can use the menu command File  Print  Object List to print a list of the selected objects on the default printer . The list contains the object information which is displayed in th[...]

  • Page 20

    New Functions in V ersion V4.02 20 Supplement to the STEP 7 User Manual V4.0 C79000-Z7076-C552-01[...]