Siemens SITRANS RD100 manual

1
2
3
4
5
6
7
8
9
10
11
12

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Siemens SITRANS RD100, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Siemens SITRANS RD100 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Siemens SITRANS RD100. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Siemens SITRANS RD100 should contain:
- informations concerning technical data of Siemens SITRANS RD100
- name of the manufacturer and a year of construction of the Siemens SITRANS RD100 item
- rules of operation, control and maintenance of the Siemens SITRANS RD100 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Siemens SITRANS RD100 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Siemens SITRANS RD100, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Siemens service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Siemens SITRANS RD100.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Siemens SITRANS RD100 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    SITRANS Remo te Displa ys SITRANS RD100 Operating Instructions 01/2011[...]

  • Page 2

    © Siemens AG 2011 Safety Guidelines: Warning notices must be observed to ensure p ersonal safety as well as that of others, and to protec t the product and the connected equipment. These war ning notices are accompanied by a clarification of the level of caut ion to be observed. Qualified Personnel: This device/sys tem may only be set up and opera[...]

  • Page 3

    7ML19985JU0 1 SITRANS RD10 0 – INSTRUCTION MANUA L P a ge 1 SITRANS RD1 0 0 Loop P ower ed Met er SITRANS RD1 0 0 SITRANS RD10 0 is a 2-wire loop powered, NE MA 4X enclosed r emot e digital display for proc ess instrumentation. This digital meter is easy to use with a display of 3.5 digits, 1" (2.54 cm) high. It accepts 4 to 20 mA input and [...]

  • Page 4

    P age 2 SITRANS RD10 0 – INSTRUCTION MANU AL 7ML19985JU0 1 Specifications Display • 1 .0 " (25.4 mm) high LCD , numeric display r ange from -10 0 0 to 1999 Enclosure • Impact-resistant glass-filled polycarbonate body • Color: gray • Impact-resistant clear polyc arbonat e cover: NEMA 4X, T ype 4X, IP67 Mounting • Standard: • wall [...]

  • Page 5

    7ML19985JU0 1 SITRANS RD10 0 – INSTRUCTION MANUA L P age 3 Calibration • T wo-step; non-intera cting low and high Calibration Range • 4 mA input: display of -10 0 0 to +10 0 0 counts • 20 mA input: display of 4 mA count value +20 to 20 0 0 counts, to a max. display of 1999 c ounts Accurac y • ±0. 1% of span ±1 c ount Conversion Rate •[...]

  • Page 6

    P age 4 SITRANS RD10 0 – INSTRUCTION MANU AL 7ML19985JU0 1 Mounting W all Mounting Dimensions A: 80 mm (3. 1 5") C: 60 mm (2.36") E: 65 mm (2.56") B: 140 mm (5.51") D: 120 mm (4.7 2") F: 20 mm (0.79") W all mounting holes: Ø 4 mm (0. 16") W eight: 340 g (12 oz) SIDE VIEW wall mounting holes beneath cove r s cre[...]

  • Page 7

    7ML19985JU0 1 SITRANS RD10 0 – INSTRUCTION MANUA L P age 5 Optional P anel Mounting Kit Instructions 1 . Insert t he RD10 0 through the mounting plat e. 2. Mount the complete assembly on the panel. 3. Secur e with 4 brackets and 4 screws (supplied) at the corner s of the met er . Use washers as needed to allow for pane l thickness. Notes • The [...]

  • Page 8

    P age 6 SITRANS RD10 0 – INSTRUCTION MANU AL 7ML19985JU0 1 Connections Ca libr ator c onnec ted to inp ut s igna l PC B Control loop c onnect e d to input signal PCB display PCB c omponent side (may be r emoved for benc h calibr ation) LO cali bration c ontrol HI calibration control balanc e cont rol (factory adju st only) DP2 DP3 DP1 S+ S- black[...]

  • Page 9

    7ML19985JU0 1 SITRANS RD10 0 – INSTRUCTION MANUA L P age 7 Ca libr ator c onnec ted to dis play PCB WA R N I N G S : • T o maintain hazardous area protection, the input signal must always be c onnected t o the input signal PCB, and not directly to the display PCB. • Electrostatic hazard. Clean only with a moist cloth. Protect enclosure from e[...]

  • Page 10

    P age 8 SITRANS RD10 0 – INSTRUCTION MANU AL 7ML19985JU0 1 Se t up For c alibration, a c alibrated curr ent sourc e and a scr ewdriver ar e required. Calibration connections T o access the input t erminals, remov e the enclosure cover and the display PCB . 1 . Loosen the four screws on the enclosure cov er and remove the co ver . 2. Completely lo[...]

  • Page 11

    7ML19985JU0 1 SITRANS RD10 0 – INSTRUCTION MANUA L P age 9 further det ails. W all mounti ng holes are loc a t ed in each c orner of the enclosure (see Mounting on page 4). Loop connections Disconnect power to the loop and install the meter as illustrated in Control loop connected to input sign al PCB on page 6 and Removing display PCB fr om the [...]

  • Page 12

    www .siemens.com/processautomation Printed in Canada www .siemens.com/weighing www .siemens.com/level For more information www.siemens.com/proces sautomation Siemens AG Industry Sector 1954 T echnology Drive P .O. Box 4225 Peterbor ough, ON Canada K9J 7B1 Subject to change without prior notice 7ML19985JU01 Rev . 1.1 email: techpubs.smpi@siemens.com[...]