Sigma AS-H40Y manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Sigma AS-H40Y, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Sigma AS-H40Y one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Sigma AS-H40Y. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Sigma AS-H40Y should contain:
- informations concerning technical data of Sigma AS-H40Y
- name of the manufacturer and a year of construction of the Sigma AS-H40Y item
- rules of operation, control and maintenance of the Sigma AS-H40Y item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Sigma AS-H40Y alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Sigma AS-H40Y, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Sigma service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Sigma AS-H40Y.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Sigma AS-H40Y item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    AS-H40Y - 12kW AS-H50Y - 15kW AS-H60Y - 18kW AL TO Hea t Pump inst alla tion manu al F1-F7[...]

  • Page 2

    1 CUSTOMER NAME........................................................................ POOL DEALER.............................................................................. DA TE INST ALLED.......................................................................... SERIAL NO........................................................................[...]

  • Page 3

    HEA T PUMP- AS-H40Y 12kW 2[...]

  • Page 4

    3 HEA T PUMP- AS-H50Y (15kW) & AS-H60 (18kW)[...]

  • Page 5

    INST ALLA TION AND SITING Prior to installing your heat pump:- All heat pumps are factory assembled and tested prior to delivery . Please check for any external damage especially to the evaporator fins, please diagram below . Do not be concerned about minor damage or indent ations to the fins (especially where the fan unit is mounted) as it will no[...]

  • Page 6

    5 PLUMBING Alto heat pumps are supplied with 1.5" BSP parallel threads, male. We strongly recommend a 1.5" female socket union is applied to inlet/outlets for future draining and servicing of the appliance. Alto heat pumps must be inst alled in the return line after the filter . If an existing heater or back-up heater has been installed t[...]

  • Page 7

    N L ON OFF CONT A CTOR 12 HEA TER Red Black OUTLET FLOW SWITCH OPERA TION WA TER FLOW FROM PUMP SOCKET UNION TEE INLET OFF ON Alternat ive w irin g route SOCKET UNION RETURN W A TE R FLOW TO POOL 1. Insert reducing bushes (provided) into 1.5” T ee using suitable adhesive. 2. Connect 1.5” T ee to socket union adjacent to Inlet on heat pump. T ee[...]

  • Page 8

    7 Ball Va l v e BACK WASH FILTER FIL TER Pool Position for option al Erosion Fe eder Non-Retur n V alve Back-Up Heater if required Condensat e W ater to waste PUMP Female/ Threade d Socket Union Drw .1 Recommended plumbing layout for a st andard heat pump installation. Drw .2 Recommended plumbing layout when incorporating Solar Heating. If an incre[...]

  • Page 9

    Ball Va l v e BACKW ASH FIL TER FIL TER Pool Non-R etu rn Valve Back-Up Heater if required Condensate W ater to waste PUMP Female/ Threaded Socket Union to be applied on all inlet/outlets Position for optional Erosion Feeder Ball Va l v e Ball Va l v e Condensate W ater to waste required or Erro sion Feede r if instal led Drw .4 Recommended plumbin[...]

  • Page 10

    9 ELECTRICAL CONNECTION & CIRCUIT DIAGRAM IMPORT ANT . It is recommended that all electrical supplies and connections are carried out by a qualified electrician , in accordance with I.E.E. standards, latest issue, or local codes of practice as applicable. Also recommended is a protected supply to incorporate fuses or motor type circuit breaker [...]

  • Page 11

    1. When electric supply is connected the ‘Run’ power light will be on and the display panel will display the current water temperature. ie.10 H = 10°C. 2. On/OFF button to turn heater on and off. 3. The ‘set’ button is used to set the F1-6 functions ie.water temperature, defrosting cycle and defrosting time etc. see pages 1 1-12 PLEASE REA[...]

  • Page 12

    11 When the ON/OFF buttons is pressed for the first time, the display panel will display the current water temperature and the desired pool temperature. eg. the display may read 10 40 ----- 10 is the current water temperature 10°C and 40 is the desired water temperature 40°C. ADJUSTING THE POOL W A TER TEMPERA TURE Using the up and down buttons, [...]

  • Page 13

    When the SET button is pressed for the fourth time, the display p anel will display:- F4 : Operation Mode. F4 C : Cooling Mode. F4 H : Heating Mode When the SET button is pressed for the fif th time, the display panel will display:- F5 : The defrosting temperature of the evaporator pipe . The recommended temperature setting for the UK should be set[...]

  • Page 14

    13 RED area RED area area RED area RED area area RED area RED area area After the water heater has been running for more than 24 hrs, it should be running at full capacity . The PSI reading should be in the region 150 -200. If you want to make the heat pump run more efficiently the water flow should be adjusted by checking the pressure meter displa[...]

  • Page 15

    E1 : the water temperature sensor is not working correctly . E2 : the tube sensor is not working correctly . Please contact your dealer . E3 : Pool filtration is running but water flow is not sensed. ‘Flow Switch’ may not be working properly or there is a lack of water flow . Backwash filter and check suction lines (Skimmer(s) & Main Drain([...]

  • Page 16

    15 AUT O REST ART AND DEFROSTING FUNCTION AUTO REST ART FUNCTION The Alto water heat pump has an auto rest art function. When the power supply is switched off accidentally , it will automatically save the operation mode. When the power supply is restored, the unit will automatically restart af ter five minutes and operate in the same working mode. [...]

  • Page 17

    WINTERISING / ST ART -UP procedure - ALL MODELS W A TER CHEMISTR Y The following water quality must be maintained at all times to prevent premature corrosion. It is recommended that your water balance is checked and balanced by a pool professional. Y our warranty does not cover for damaged caused by poor water chemistry and neglect. pH: 7.2 -7.6 T [...]

  • Page 18

    17 AL T O W ARRANTY POLICY This voluntary policy is supplement al to and in no way affects any st atutory rights which the customer may have. 1 W arranties 1.1 Paramount Pools warrants the Alto Heat Pump for a period of one (1) year from the date installed for both part s and labour . 1.2 At the end of the first year the following warranties apply [...]

  • Page 19

    HEA T PUMP SER VICE An Alto heat pump should give you many years trouble free service. However , to obtain the maximum efficiency from your heater Alto recommend that your heater is checked and serviced every 12 months. Service & extended warranty packages are available from a UK Service Agent (see contact det ail below). HEA T PUMP BREAKDOWN I[...]

  • Page 20

    Model No. AS-H40Y AS-H50Y AS-H60Y 12kW 15kW 18kW Heating Capacity (Btu) 40000 50000 60000 Cooling Capacity (Btu) 35000 42000 55000 Rated Input (W) Heating 2540 3185 3790 Cooling 2465 3020 3900 PTC Power (W) -------- -------- -------- COP for Heating (w/w) 4.42 4.40 4.44 (at 20 °C ambient air temperature) Refrigerant R407C R407C R407C Power Supply [...]