Silverstone ST50GF manual

1
2
3
4
5
6

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Silverstone ST50GF, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Silverstone ST50GF one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Silverstone ST50GF. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Silverstone ST50GF should contain:
- informations concerning technical data of Silverstone ST50GF
- name of the manufacturer and a year of construction of the Silverstone ST50GF item
- rules of operation, control and maintenance of the Silverstone ST50GF item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Silverstone ST50GF alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Silverstone ST50GF, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Silverstone service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Silverstone ST50GF.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Silverstone ST50GF item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Industry-leading reliability 500+500W watts maximum output power (ST50GF) 420+420W watts maximum output power (ST42GF) High efficiency with 80Plus Silver certification (ST50GF) High efficiency with 80Plus bronze certification (ST42GF) 1+1 redundant configuration PS2 mini redundant power Hot swappable design Power fault Alarm signals Durable zinc-pl[...]

  • Page 2

    ST50GF / ST42GF SPECIFICA TION SilverStone GEMINI SST -ST50GF SST -ST42GF Mini Redundant Switching Power Supply With Active PFC 500W+500W 420W+420W 1. Input Requirements 1-1. Input V oltage The power supply shall be operated at universal input voltage defined in the following table. 1-2. Frequency The input frequency range is from 47Hz to 63Hz. 1-3[...]

  • Page 3

    ST50GF / ST42GF 2-2. DC Load Requirements SST -ST50GF Note : 1. The maximum continuous total DC output power shall not exceed 500 W atts. 2. The maximum continuous combined load on +5V and +3.3V outputs shall not exceed 170 W atts. 3. The maximum continuous combined load on +5V , +3.3V and +12V , outputs shall not exceed 488 W atts. SST -ST42GF Not[...]

  • Page 4

    ST50GF / ST42GF 05 MAX 600 ms Units MAX 100 ms Units 2-6. T otal Output Power SST -SG50GF SST -ST42GF 2-7. Remote ON/OFF Control The power supply outputs shall be enabled with an active-low TTL signal. When TTL signal is low , the DC outputs are to be enabled. When TTL signal is high or open circuited, the DC outputs are to be disabled. Electronic [...]

  • Page 5

    ST50GF / ST42GF 3-2. Short Circuit Pr otection A short circuit placed to ground shall cause no damage or power supply shall be shutdown. (The contact resistance is 0.05 ohm when the outputs short circuit.) 3-3. Protection Reset When the power supply latches into shutdown condition due to a fault on an +5V ,+3.3V ,+12V , output (OVP , UVP ,OCP), the[...]

  • Page 6

    ST50GF / ST42GF 14. Redundant Output Signal: 15. Dimension 15-1. Dimension (W x H x D) : 150mm(5.90”) x 86mm(3.38”)x 193mm(7.59”) 15-2. Connectors M/B 24PIN connector 09 Orange Orange Blue Black Green Black Black Black White Red Red Red Red Black Orange Black Red Black Red Black Grey Purple Y ellow Orange 1 +3.3V Orange 10 +12V Y ellow Signal[...]