Simer Pumps 2905 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Simer Pumps 2905, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Simer Pumps 2905 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Simer Pumps 2905. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Simer Pumps 2905 should contain:
- informations concerning technical data of Simer Pumps 2905
- name of the manufacturer and a year of construction of the Simer Pumps 2905 item
- rules of operation, control and maintenance of the Simer Pumps 2905 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Simer Pumps 2905 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Simer Pumps 2905, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Simer Pumps service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Simer Pumps 2905.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Simer Pumps 2905 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Installation/Operation/Parts For further operating, installation, or maintenance assistance: Call 1-800-468-7867 English . . . . . . . . . . . . . . Pages 2-6 Installation/Fonctionnement/Pièces Pour plus de renseignements concernant l’utilisation, l’installation ou l’entretien, Composer le 1 (800) 468-7867 Français . . . . . . . . . . . Pag[...]

  • Page 2

    Safety 2 F or par ts or assistance, call Simer Customer Ser vice at 1-800-468-7867 / 1-800-546-7867 READ AND FOLLOW SAFETY INSTRUCTIONS! Carefully read and follow all safety instructions in this manual and on pump. This is the safety alert symbol. When you see this symbol on your pump or in this manual, look for one of the fol- lowing signal words [...]

  • Page 3

    F or par ts or assistance, call Simer Customer Ser vice at 1-800-468-7867 / 1-800-546-7867 General Information / Installation 3 14. Protect the electrical cord from sharp objects, hot surfaces, oils, and chemicals. A void kinking the cord. Replace or repair damaged or worn cords immediately . 15. Do not touch an operating motor . Motors can operate[...]

  • Page 4

    F or par ts or assistance, call Simer Customer Ser vice at 1-800-468-7867 / 1-800-546-7867 Installation / Operation / Maintenance 4 5. Power Supply: This pump is designed for 1 15 V ., 60 Hz., operation and requires a minimum 15 amp individual branch circuit. Both the pump and switch are supplied with 3-wire cord sets with grounding-type plugs. The[...]

  • Page 5

    Maintenance 5 F or par ts or assistance, call Simer Customer Ser vice at 1-800-468-7867 / 1-800-546-7867 AIRLOCKS: When a pump airlocks, it runs but does not move any water . An airlock will cause the pump to overheat and fail. This pump has a small hole in the side of the pump housing. See Figure 1. This is an anti-airlock valve. If you suspect an[...]

  • Page 6

    Repair P arts 6 F or par ts or assistance, call Simer Customer Ser vice at 1-800-468-7867 / 1-800-546-7867 3 5 7 8 1 2 2 6 4 2 Anti-airlock hole 4279 1102 2905 Key Part No. Description Qty . 2905 2955 1 Power Cord 1 2909-B 2909-B 2 Screws, Handle, Screen, Clamp 6 670-646 670-646 3 Handle 1 383-147-B 383-147-B 4 Coupling, 1-1/4" x 1-1/4" F[...]

  • Page 7

    Sécurite 7 P our obtenir des pièces ou de l’aide, appeler le Service à la clientèle Simer en composant le 1 800 468-7867/1 800 546-7867 LIRE TOUTES CES INSTRUCTIONSET LES SUIVRE! Lire attentivement toutes les consignes de sécurité contenues dans cette Notice et collées sur la pompe. Ce symbole indique qu’il faut être prudent. Lorsque ce[...]

  • Page 8

    P our obtenir des pièces ou de l’aide, appeler le Service à la clientèle Simer en composant le 1 800 468-7867/1 800 546-7867 Renseignements généraux / Installation 8 14. Protéger le cordon électrique de la pompe contre les objets tran- chants, les surfaces chaudes, l’huile et les produits chimiques. Éviter de tortiller le cordon électr[...]

  • Page 9

    P our obtenir des pièces ou de l’aide, appeler le Service à la clientèle Simer en composant le 1 800 468-7867/1 800 546-7867 Installation / F onctionnement 9 5. Courant électrique : Cette pompe est conçue pour fonctionner sur le courant alternatif de 1 15 V , 60 Hz et sur un circuit séparé de 15 ampères minimum. La pompe et l’interrupte[...]

  • Page 10

    Entr entien 10 P our obtenir des pièces ou de l’aide, appeler le Service à la clientèle Simer en composant le 1 800 468-7867/1 800 546-7867 BOUCHONS D’AIR Si des bouchons d’air se forment dans la pompe, la pompe continuera de fonctionner mais ne débitera pas d’eau. Un bouchon d’air peut causer la surchauffe de la pompe, et éventuelle[...]

  • Page 11

    Pièces de r echange 11 P our obtenir des pièces ou de l’aide, appeler le Service à la clientèle Simer en composant le 1 800 468-7867/1 800 546-7867 3 5 7 8 1 2 2 6 4 2 Anti-airlock hole 4279 1102 2905 Réf. Désignation Qté 2905 2955 1 Cordon électrique 1 2909-B 2909-B 2V is de poignée, de crépine et de collier 6 670-646 670-646 3 Poigné[...]

  • Page 12

    Seguridad 12 Si necesita repuestos o asistencia llame al Servicio al Cliente de Simer , 1-800-468-7867/1-800-546-7867 LEA Y OBSER VE LAS INSTRUCCIONES DE SEGURIDAD Lea con atención y siga todas las instrucciones de seguridad que apare- cen en este manual y en la bomba. Este es un símbolo de alerta de seguridad. Cuando vea este sím- bolo en su bo[...]

  • Page 13

    Si necesita repuestos o asistencia llame al Servicio al Cliente de Simer , 1-800-468-7867/1-800-546-7867 Información General / Instalación 13 14. Proteja el cordón eléctrico de objetos afilados, superficies calientes, aceites y sustancias químicas. Evite que el cordón se tuerza. Reemplace o repare inmediatamente todo cordón averiado o gastad[...]

  • Page 14

    Si necesita repuestos o asistencia llame al Servicio al Cliente de Simer , 1-800-468-7867/1-800-546-7867 Instalación / Operación 14 5. Suministro de corriente eléctrica. Esta bomba ha sido diseñada para funcionar a 1 15V , 60 Hz.y requiere un ramal individual de 15 amperios como mínimo. T anto la bomba como el interruptor vienen con un juego d[...]

  • Page 15

    Mantenimiento 15 Si necesita repuestos o asistencia llame al Servicio al Cliente de Simer , 1-800-468-7867/1-800-546-7867 BOLSAS DE AIRE Cuando una bomba tiene obturaciones por bolsas de aire, funciona pero no mueve el agua. Una bolsa de aire hará que la bomba se recaliente y falle. Esta bomba tiene un pequeño orificio del lado de la caja de la b[...]

  • Page 16

    Piezas de r epuesto 16 Si necesita repuestos o asistencia llame al Servicio al Cliente de Simer , 1-800-468-7867/1-800-546-7867 3 5 7 8 1 2 2 6 4 2 Anti-airlock hole 4279 1102 2905 Clave Descripción de No. la pieza Cant. 2905 2955 1 Cordón eléctrico 1 2909-B 2909-B 2T ornillos, mango, criba, abrazaderas del mango 6 670-646 670-646 3 Mango 1 383-[...]