Go to page of
Similar user manuals
-
Boiler
Slant/Fin VHS-30
27 pages 0.98 mb -
Boiler
Slant/Fin Monitron Monitron EH Boilers
4 pages 0.67 mb -
Boiler
Slant/Fin VH-180
2 pages 0.09 mb -
Boiler
Slant/Fin B-200A
12 pages 2.59 mb -
Boiler
Slant/Fin SX-210
20 pages 0.45 mb -
Boiler
Slant/Fin V-180
20 pages 0.72 mb -
Boiler
Slant/Fin SE-245
1 pages 0.05 mb -
Boiler
Slant/Fin KC-50
4 pages 0.09 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Slant/Fin B-120A, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Slant/Fin B-120A one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Slant/Fin B-120A. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Slant/Fin B-120A should contain:
- informations concerning technical data of Slant/Fin B-120A
- name of the manufacturer and a year of construction of the Slant/Fin B-120A item
- rules of operation, control and maintenance of the Slant/Fin B-120A item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Slant/Fin B-120A alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Slant/Fin B-120A, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Slant/Fin service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Slant/Fin B-120A.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Slant/Fin B-120A item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
Residential • Gas fired • Hot W ater Boilers User’ s Infor mation Manual Bobcat Direct-V ent Sealed Combustion Condensing Boiler Model B-120A and B-200A FOR YOUR SAFETY : • Bef ore operating this boiler , READ this manual. • DO NO T attempt to install, ser vice or repair this boiler y ourself. There are no user ser viceable par ts. Contac[...]
-
Page 2
Bobcat Model B-120A and B-200A 2 WELCOME TO OUR V ALUED CUSTOMER Y ou are now the o wner of a Slant/Fin Bobcat series gas-fired boiler , another quality heating product designed and manu- f actured by an industry leader , to provide your f amily with many y ears of reliable comf or t and trouble-free perf or mance. The care and maintenance of your [...]
-
Page 3
Bobcat Model B-120A and B-200A 3 I NSPECTION Y our boiler and heating system will last an indefinitely long time at full efficiency , if it is inspected regular ly and is kept in good repair and adjustment. Y ou, the user , should make r egular inspections, and repor t any prob lems to your s er vice agency . At regular inter v als, y ou should hav[...]
-
Page 4
Bobcat Model B-120A and B-200A 4 3 IN. DIA. VENT PIPE AIR INT AKE (DO NOT BLOCK) VENT TERMINA TION OUTSIDE W ALL Figure 4. Non-direct vent, sidewall venting.[...]
-
Page 5
Bobcat Model B-120A and B-200A 5 Figure 5. Non-direct vent, venting through the roof. V ENT TERMINA TION 3 IN. DIA. VENT PIPE AIR INT AKE (DO NOT BLOCK) Figure 6. Non-direct vent, utilizing an existing chimne y as a chase . CHIMNEY T OP PL AT E 3 INCH DIA. VENT PIPE 3 INCH DIA. VENT PIPE AIR INT AKE (DO NOT BLOCK) UNUSED CHIMNEY VENT TERMINA TION[...]
-
Page 6
Bobcat Model B-120A and B-200A 6 2. CONDENSA TE REMOV AL SYSTEM The Bobcat B-120 and B-200 boilers are equipped with a built-in condensation dr ain and trap . The trap must be filled with water . DO NO T operate the boiler without fill- ing the trap with w ater to pre vent flue gas discharge into space. P er iodic inspection should be made of this [...]
-
Page 7
Bobcat Model B-120A and B-200A 7 The combustion air supply m ust not be susceptible to contaminants, which ma y cause corrosion or other damage to the heat e xchanger and components of the b oiler , causing failure of these parts or unsafe o peration. Below is a list of products which must be a voided from being stored or entering the boiler room o[...]
-
Page 8
Bobcat Model B-120A and B-200A 8 Removing Jac ket Front P anel 1. T ur n black scre ws 1 ⁄ 4 tur n to open position. 2 . Remov e front panel. T o replace the panel, rev erse procedure. INTEGRA TED BOILER CONTROL The integrated boiler control monitors the status of the room ther mostat, high limit s witch, low water cutoff (if installed), water in[...]
-
Page 9
Bobcat Model B-120A and B-200A 9 Mode Displa y Description & T emperature Display Boiler is on stand-b y mode. T emperature displa y shows supply w ater T emp . Space heating mode. T emperature displa y shows supply w ater T emp . Domestic hot water mode . T emperature displa y shows supply w aterT emp . F rost protection mode.** T emper ature [...]
-
Page 10
Bobcat Model B-120A and B-200A 10 Mode Displa y Description & T emperature Display Space heating supply water temper ature could be changed b y pressing “Up/Down” b utton. Settable from 90˚F to 185˚F (steps of 1 F). The def ault valv e is 176˚ F Press “Enter” button to store . (see note 1) Domestic hot water supply temper ature could[...]
-
Page 11
Bobcat Model B-120A and B-200A 11 DIA GNOSTIC ERROR CODES W ARNING: I f an operational prob lem has occurred, the boiler will s hut off and show an “A”, “E” or “H” in the mode display , along with an error code in the temperature displa y . Do not attempt perf or ming any ser vice under these conditions, b ut do note the mode and temper[...]
-
Page 12
SLANT/FIN CORPORA TION, Green vale, N.Y . 11548 • Phone: (516) 484-2600 F AX: (516) 484-5921 • Canada: Slant/Fin L TD/L TEE , Mississauga, Ontar io www .slantfin.com © Slant/Fin Corp. 2008[...]