Go to page of
Similar user manuals
-
Switch
SMC Networks SMC6724L3
618 pages 7.54 mb -
Switch
SMC Networks SMC-EZ1024DT
32 pages 0.31 mb -
Switch
SMC Networks TigerSwitch
518 pages 5.03 mb -
Switch
SMC Networks SMC6624M
364 pages 3.59 mb -
Switch
SMC Networks EZNET-24SW
2 pages 0.45 mb -
Switch
SMC Networks TigerStack 100 1000BASE-X
178 pages 1.33 mb -
Switch
SMC Networks SMC8524T
2 pages 0.06 mb -
Switch
SMC Networks SMC7824M/ESW
104 pages 5.56 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of SMC Networks EX9-AC020EN-PSRJ, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of SMC Networks EX9-AC020EN-PSRJ one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of SMC Networks EX9-AC020EN-PSRJ. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of SMC Networks EX9-AC020EN-PSRJ should contain:
- informations concerning technical data of SMC Networks EX9-AC020EN-PSRJ
- name of the manufacturer and a year of construction of the SMC Networks EX9-AC020EN-PSRJ item
- rules of operation, control and maintenance of the SMC Networks EX9-AC020EN-PSRJ item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of SMC Networks EX9-AC020EN-PSRJ alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of SMC Networks EX9-AC020EN-PSRJ, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the SMC Networks service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of SMC Networks EX9-AC020EN-PSRJ.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the SMC Networks EX9-AC020EN-PSRJ item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
Reduced wiring system EX250 - SEN1 Instruction Manual EtherNet/IP™ Compatible SI Unit URL http:// www.smcworld.com Specifications are subject to change without prior notice and any obligation on the part of the manufacturer. EtherNet/IP™ is a trademark used under licence by ODVA. The descriptions of products shown in this document may be used b[...]
-
Page 2
Contents Thank you for purchasing the SMC reduced wiring system EX250 series. Please read this instruction manual carefully and understand the contents before use so that you can operate this unit safely and correctly. Please keep this manual handy for future reference. OPERA T OR This instruction manual has been written for those who ha ve kno wle[...]
-
Page 3
2 3 SAFETY The body of unit and this manual contain the essential information for the protection of users and others from possible injury and property damage and to ensure correct handling. Please check that you fully understand the definitions of the following messages ( symbols ) before going on to read the body of this manual, and always follow [...]
-
Page 4
4 5 Pr oduct Summar y Power supply for Output Block (for high wattage load) 24VDC Connecting to bus at upper level (EtherNet/IP) Power supply for output/input and control 24VDC Solenoid valve Output Block (for high wattage load) Power Block Output Block (for low wattage load) SI Unit applicable to EtherNet/IP Input Block End Plate This system reali[...]
-
Page 5
6 7 SI Unit Model Indication Method Ti e-rod (2 pcs.) Accessory Note1 : For wiring method, refer to subsection "Wiring" (page 12) in this manual. Note2 : For display and setting method, refer to subsection "Display/Setting" (page 15) in this manual. Dimensions ( unit : mm ) BUS BUS PWR PWR SOL SOL NS NS PWR PWR SETTINGS SETTINGS[...]
-
Page 6
8 9 Mounting/Installation (continued ) Layout of the Input Block Position the Input Block on the left side of the SI Unit. Layout of the EX9 series Output Block / Power Block Position the Output Block / Power Block on the right side of the SI Unit and between the SI Unit and solenoid valve or End Plate R (on the Output Block side). 1) Output Block [...]
-
Page 7
10 11 Specifications Sensor input area 1 0 I/O mapping Offset (word) Input data MSB LSB MSB LSB 15 8 70 0 1 Input area mapping 15 14 L : Fixed to Low Item Status Condition SP Solenoid power supply status 0 No supply voltage 1 Supply voltage OK DI Status of sensor power supply 0 Short circuit 1 Normal Diagnostics (Status input area) 2 LL LL LL LL L [...]
-
Page 8
12 13 Wiring 43 2 1 1 34 2 M12 1 2 +Rx 3 - Tx 4 - Rx 1 2 3 4 5 6 7 8 Shield RJ45 6.7 47.3 45 2000 Model No. : EX9-AC020EN-PSRJ +Tx Wiring diagram Cable core wire external color Terminal No. Pin assignment of plug connector Pin assignment of plug connector White/Orange Orange White/Green Green 8 7 6 5 4 3 2 1 Connect the Power Supply Cable to the po[...]
-
Page 9
14 15 Wiring ( continued ) 24VDC 24VDC Brown : 24VDC (for solenoid valv es/output) White : 0V (for solenoid valv es/output) Grey : Ear th Blue : 24VDC (for input and control) Black : 0V (for input and control) Cable P ar t No . : EX500-AP -S 24VDC Brown : 24VDC (for solenoid valv es/output) White : 0V (for solenoid valv es/output) Grey : Ear th Blu[...]
-
Page 10
16 17 12345678 ON 1 0 IP address 192.168.0.X 1 0 1 0 1 0 1 2 0 0 1 1 1 1 3 0 0 0 0 1 1 4 0 0 0 0 1 1 Remote control * 1 X 3 2 1 14 DHCP mode * 2 SW1 Communication setting CLEAR/HOLD Manual set up of IP address * 3 SW1 5 0 1 1 1 1 1 6 - - 0 1 - - 7 - - - - 0 1 SW1 Item Communication setting Communication speed Communication method Contents AUTO : Th[...]
-
Page 11
18 19 Input Bloc k Model Indication Method EX250 IE Block type 1 2 3 Input points : 2, M12 connector (2pcs.) Input points : 4, M12 connector (2pcs.) Input points : 4, M8 connector (4pcs.) Input Block Model indication method Pa rt Names No. Part names Application 1 Input equipment connector Connects the input equipment such as sensor, etc. Note1 2 O[...]
-
Page 12
20 21 Wiring EX250-IE3 EX250-IE1/2 EX250-IE1 (M12 connector, 5 pin, Socket) EX250-IE2 (M12 connector, 5 pin, Socket) *1) Input No.1 is connected to the pin No.2 of the input connector "0", 2 input signals can be directly input from the input connector "0". *2) NC : Not connected EX250-IE3 (M8 connector, 3 pin, Socket) 1 1 2 2 3 [...]
-
Page 13
22 23 Displa y/Setting EX250-IE1 EX250-IE2/IE3 0 0 1 1 EX250 EX250 0 0 1 1 2 2 3 3 EX250 EX250 Display Description PWR Lights up Power supply for sensor is ON. Off Power supply for sensor is OFF. 0, 1, 2, 3 Lights up Sensor signal input corresponding to the number is ON. (Logic "1") Off Sensor signal input corresponding to the number is O[...]
-
Page 14
24 25 Pa rt Names T ie-rod (2 pcs.) Accessory T ie-rod (2 pcs.) Accessory W aterproof cap (for socket)(1 pc.) Dimensions ( unit : mm ) 59.8 72.6 21 Output Block 59.8 80.3 21 PWR PWR Po wer Bloc k Mounting/Installation Refer to subsection "Mounting/Installation" (page 7) in this manual. Specifications Model No. EX9-OET1 EX9-OEP1 Power supp[...]
-
Page 15
26 27 Wiring ( continued ) Output connector pin lay out EX9-OET1, EX9-OEP1 (M12 connector, 5 pin, Socket) Output No.1 *1 Output No.0 NC *2 1 NC *2 3 GND 5 NC *2 4 4 1 1 4 4 1 1 2 2 3 3 2 2 3 3 5 5 5 5 Output connector "0" Output connector "1" Output wiring Cable wiring Pin alignment and connection drawing of the Output Cable Plu[...]
-
Page 16
28 29 Wiring ( continued ) M12 connector, 5 pin, Reverse key 1 Power supply for output (24VDC) 2 Power supply for output (0VDC) 5 Ground ( 3 Power supply for sensor (24VDC)) * ( 4 Power supply for sensor (0V)) * 4 4 1 1 4 4 1 1 2 2 3 3 2 2 3 3 5 5 5 5 Power supply connector (Socket) Power input connector (Plug) * It is used when power is supplied t[...]
-
Page 17
30 31 Wiring ( continued ) Displa y Output Block PWR PWR Po wer Bloc k The Power Supply Cable (for Power Supply Connector of Power Block) is a bypass cable which can be used when the Power Block is positioned next to the SI Unit. Option EX500 - AP 050 - S How to order Cable length (L) Connector specification 010 1 [m] 050 5 [m] S Straight EX9 - AC [...]
-
Page 18
32 33 Option ( continued ) Waterproof Cap Mounted on the unused ports of the Input Block, Output Block and Power Block. The proper use of this Waterproof Cap can achieve IP67 Enclosure. (The Waterproof Caps are delivered together with the Power Block as accessories.) 9 EX500 - AW How to order Connector specification ES M8 connector ( for socket ) /[...]
-
Page 19
34 Tr oubleshooting ( continued ) MS LED status Normal status : Green light ON Fatal failure : Red light ON 1 The effect of noise is possible. Check the installation conditions. If the trouble cannot be solved even if the installation conditions are checked, contact our sales branch. NS LED status Offline/Power is OFF : Light OFF Online/Communicati[...]