SMC Networks Redundant Power Unit SMCRPU600W manual
- Read online or download the manual
- 22 pages
- 0.27 mb
Go to page of
Similar user manuals
-
Network Card
SMC Networks SMC EZ Connect g MIMO Wireless PCI Adapter SMCWPCI-GM
2 pages 0.41 mb -
Network Card
SMC Networks EZ Connect 2.4GHz 54Mbps Wireless Cable Modem Gateway SMC8013WG-G
2 pages 0.5 mb -
Network Card
SMC Networks SMC10GPCIe-10BT
2 pages 0.15 mb -
Network Card
SMC Networks EZ Card 10/100 SMC1244TX-1
2 pages 0.27 mb -
Network Card
SMC Networks SMC EZ Connect N Pro Draft 11n Wireless CardBus Adapter SMCWCB-N2
36 pages 1.82 mb -
Network Card
SMC Networks 2102
8 pages 0.21 mb -
Network Card
SMC Networks EtherNet/IP EX500-GEN1
23 pages 1.52 mb -
Network Card
SMC Networks SMC2835W
33 pages 1.25 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of SMC Networks Redundant Power Unit SMCRPU600W, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of SMC Networks Redundant Power Unit SMCRPU600W one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of SMC Networks Redundant Power Unit SMCRPU600W. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of SMC Networks Redundant Power Unit SMCRPU600W should contain:
- informations concerning technical data of SMC Networks Redundant Power Unit SMCRPU600W
- name of the manufacturer and a year of construction of the SMC Networks Redundant Power Unit SMCRPU600W item
- rules of operation, control and maintenance of the SMC Networks Redundant Power Unit SMCRPU600W item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of SMC Networks Redundant Power Unit SMCRPU600W alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of SMC Networks Redundant Power Unit SMCRPU600W, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the SMC Networks service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of SMC Networks Redundant Power Unit SMCRPU600W.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the SMC Networks Redundant Power Unit SMCRPU600W item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
Redundant Po wer Unit F ault-tolerant netw orking! ◆ Separate A C line cord ◆ Supports four switches ◆ Easy management LEDs ◆ One rack unit high User Guide SMCRPU600W[...]
-
Page 2
[...]
-
Page 3
38 T esla Irvine, CA 92618 Phone: (949) 679-8000 Redundant P o wer Unit User Guide March 2003 Pub. # 15 xxx R01[...]
-
Page 4
Infor mation fur nished by SMC Ne tw orks , Inc. (SMC) is believed to be accurate and reliable. Howev er, no responsibilit y is assumed by SMC for its us e, nor for any infring ements of pate nts or other rights of third parties which m ay resul t from its use . No licen se is granted by impli cation or otherwis e under any patent o r patent rights[...]
-
Page 5
i L IMITED W ARRANTY Limited W ar ranty Statement : SMC Netw orks , Inc . (“SMC”) warrants its products to be free from defects in workma nship and materials , under nor mal use and ser vice, for the applicable warranty ter m. All SMC products carr y a standard 90-day limited w ar ranty from the date of purchase from SMC or its A uthoriz ed Res[...]
-
Page 6
L IMITED W AR RANTY ii WARRANTIES EX CLUSIVE: I F AN SMC PRODUCT DOES NOT OPERA TE AS W ARRANTED ABO VE, CUSTOMER’S SOLE REMED Y SHALL BE REP AIR OR REPLA CEMENT OF THE PRODUCT IN Q UESTION , A T SMC’S OPTION . THE FOREGOING W ARRANTIES AND REMEDI ES ARE EXCLUSIVE AND ARE IN LIEU OF ALL OTHER W ARRANTIES OR CONDITIONS , EXPRESS OR IMPLIED , EIT[...]
-
Page 7
iii C OMPLIANCES FCC - Class A This equipment g enerates, uses , and can radiate radio frequency energ y and, if not installe d and used in ac cordance with the in str uction manual, m ay cause interferenc e to radio communications . It has been tested and found to comply with the limits for a Class A computing device pursuant to Subpar t B of P a [...]
-
Page 8
C OMPLIANCES iv EC Confor mance D eclaration - Class A SMC contact for these pr oducts in Europe is: SMC Networks Europe , Edificio Conat a II, Calle Fructuós Gelabert 6-8, 2 o , 4 a , 08970 - Sant J oan Despí, Barcelona, Spain. This infor mation technolog y equipment compli es with the requ irements of the Council Direct iv e 89/336/EEC on the A[...]
-
Page 9
C OMPLIANCES v J apan V CCI Class A Australia AS/NZS 3548 (1995) - Class A SMC contact for products in Australia is: SMC-Au stralia L9, 123 Epping Rd, North Ryd e, NSW A ustralia Phone: 61-2-88757887 Fax: 61-2-8875777 7[...]
-
Page 10
C OMPLIANCES vi Safety Compliance Wichtige Sicherheitshinw eise (Ger many) 1. Bitte lese n Sie diese Hinweise sorg fältig durch. 2. Heben Sie diese Anleitung fü r den späteren Gebrau ch auf . 3. V or jedem Reinig en is t das Ge rät vom Stro mnetz z u trenne n. V er wenden Sie kei ne Flüssig oder Aeros olreinig er . A m besten ei gnet sich ein [...]
-
Page 11
vii T ABLE OF C ONTENTS About the Redundant Power Unit . . . . . . . . . . . . . . . . . . . . . . 1 Feature s and Benefits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Front and Rea r Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 LEDs 2 Installing the RPU . . . . . .[...]
-
Page 12
T ABLE OF C ONTENTS viii[...]
-
Page 13
1 A BOUT THE R EDUNDANT P OWER U NIT SMC’ s Redundant P ower Unit (RPU), SMCRPU600W , can supply 600 W atts of backup po wer to four SMC device ( hubs or switch es) in the ev ent of an A C loss or failure of an inte rnal power supply . Please check with SMC for infor mation on the devices supported by this RPU . Features and Benefits • Supports[...]
-
Page 14
A BOUT THE R EDUNDANT P OWER U NIT 2 LEDs LED Status Description RPS On Green Power is bein g supplied to the RPU, normal ly operation, and connected to switc h. Flashing Power is be ing supplied to the RPU and no rmally operatio n, but no conn ection to the switch. Off Power is of f or failure occurred. FAN On Green Fan is workin g normally. Flash[...]
-
Page 15
3 I NSTALLING THE RPU The RPU may be placed on a de sktop or mounted in a rack. Caution: W ar ning: DO NOT place the RPU on the floor as the case is not waterproof . RPU Packing List • Redundant Power Unit — provid es backup power to four SMC devices • One AC Supply Power Cord — US, Continental Europe or UK • One DC Backup Power Cord — [...]
-
Page 16
I NSTALLI NG THE RPU 4 Making Connections Caution: Caution:DO NOT connect the RP U to an A C power source until the DC pow er cord has been connected to the other device (hub or switch). 1. Connect one end of the AC cord to the AC rece ptacle on the supported devices (hubs or switches), and the other end to a grounded power outlet. 2. Use the provi[...]
-
Page 17
5 S PECIFICATIONS SMCRPU600W Receptacle IEC Sock et 216 C743-07 Siz e 440 x 285 x 430 mm (17.37 x 11.25 x 1.7 in.) We i g h t 27.562 lb . (5.0 kg) Te m p e r a t u r e Operating: 0 to 40 °C (32 to 104 °F) Storage: -40 to 70 °C (-40 to 158 °F) Relati v e Humidity 20% to 90% Cooling 4 fans AC Input Pow er 100 to 240 V A C , 50 to 60 Hz DC P ow er[...]
-
Page 18
S PECIFICATIONS 6 Compliances Emissions FCC Class A V CCI Class A Industr y Canada Class A EN55022 (CISPR 22) Class A C-Tick - AS/NZS 3548 (1995) Class A Wa r r a n t y One year Fan Vo l t a g e +12 VDC Operating v olta ge R ange 7.0V to 13.8V Speed 8200 RPM Air Deliv er y 9.43 CFM Noise 30.5 dB Power Supply Vo l t a g e +12 VDC Initial Accuracy +/[...]
-
Page 19
S PECIFICATIONS 7 Line Regulation +/- 1% Load R egulation +/- 10% Noise and Ripple 10%, peak to peak Ov ershoot and Unders hoot 5%[...]
-
Page 20
S PECIFICATIONS 8[...]
-
Page 21
[...]
-
Page 22
38 T e sla Irvine, CA 92618 Phone: (949) 679 -8000 FOR TECHNICAL SUPPOR T , CALL: From U.S.A. and Can ada (24 hours a day , 7 days a week) (800) SMC-4 -Y OU; (949) 679-8000; F ax: (949) 679- 1481 From Europe (8:00 AM - 5:30 PM UK T ime) 44 (0) 11 8 974 8700; F ax: 44 (0) 11 8 974 8701 INTERNET E-mail addresses: techsupport@smc.com european.techs up[...]