Go to page of
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Smeg L30FABBLP, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Smeg L30FABBLP one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Smeg L30FABBLP. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Smeg L30FABBLP should contain:
- informations concerning technical data of Smeg L30FABBLP
- name of the manufacturer and a year of construction of the Smeg L30FABBLP item
- rules of operation, control and maintenance of the Smeg L30FABBLP item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Smeg L30FABBLP alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Smeg L30FABBLP, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Smeg service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Smeg L30FABBLP.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Smeg L30FABBLP item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
INST ALLA TION & USER INSTR UCTIONS All instructions must be handed to the user for saf ek eeping. Revision A - 08/07 Countr y(s) of destination - GB/IE L30 F AB P23 LINEAR, P23 CLASSIC L23 LINEAR, L23 CLASSIC MODELS W ALL MOUNTED HIGH EFFICIENCY GAS FIRE SMEG (UK) L TD 3 Milton Park Abingdon, Oxon O X14 4RN Phone: +44 (0)870 99 09 907 Fax : +4[...]
-
Page 2
L30 Fab P23 Linear P23 Classic L23 Linear L23 Classic © 2007 Smeg (UK) L TD Please note : Except where otherwise stated, all rights, including cop yright in the text, images and la y out of this booklet is owned by Smeg (UK) L TD . Y ou are not permit- ted to cop y or adapt an y of the content without the prior written permission of Smeg (UK) L TD[...]
-
Page 3
This appliance is a high efficiency , flueless catalytic flame effect gas fir e. It pro vides radiant and conv ected warmth both effi cient- ly and safel y utilising the latest type catalytic conv erter and burner technology . The appliance does not requir e a flue system of any type as the catal ytic conv erter cleans the flue products to pr ovide[...]
-
Page 4
If the appliance is to be sited near a disused or unserviceable fireplace served by a natural draught flue then the old flue mu st be sealed off. It will be necessar y to ventilate the old flue to pre v ent condensation and dampness forming, howe v er any air v ent use d to ventilate the old flue m ust not be sited within 500mm of this appliance. I[...]
-
Page 5
The appliance is designed to be v ersatile, and as such will operate correctly when exposed to normal gentle draughts experienced within the home. It is not r ecommended, howev er that the appliance be installed in ar eas wher e it is lik ely to be dir ectly expose d to persistent strong draughts, that ma y be generated by outside doors, windows, a[...]
-
Page 6
Remov e the outer packaging, remo ve an y instructions or fixing kits. Read ALL these instructions before continuing to unpack or install this a ppliance. Lift off the remaining packaging components and r emov e the contents of the bo x. Check that the components supplied corr elate with the component checklist. Please dispose of all the packaging [...]
-
Page 7
If the appliance is to be mounted on the inner leaf of a conv entional ca vity brick wall, or a solid wall, then the fibr e wall plugs and fixing scr ews pr ovided ma y be used. Depending on the condi- tion of the wall it ma y be necessary to use additional fixings. In this situation, an y additional fixings and wallplugs should be of the same size[...]
-
Page 8
Classic models : The control knob is located on the low er right hand side of the outer case.It is marked as shown in figur e 6; Linear models : The control knob is located on the low er right hand side of the outer case. It is marked as shown in figur e 7; Fab models : The contr ol knob is located on the low er right hand side of the outer case. I[...]
-
Page 9
Please note that the Linear and Classic models are supplied with a tinted glass facia assembly , which dif- fer in appearance when vie wed fr om the fr ont, simi- larly the F ab model is supplied with a metal facia, ho we ver the method of attachment to the appliance, for all frame designs, is the same . All models : Remov e the facia panel fr om a[...]
-
Page 10
All models : Firstly , r emov e the decorative frame/glass facia assembly as described in section 8.3. Remove the inner glass panel, and disconnect the gas connection inside appliance. The gas connections to the gas valve can no w be released. Detach the burner front co v er plate by r emoval of the four retaining scr e ws (as shown in figur e 9, s[...]
-
Page 11
It is recommended that the catal ysts are inspected f or signs of damage and dirt during routine servicing procedures. The expect- ed life of the catalysts is in excess of 11,000 hours (10 y ears of normal use). After this time the catalysts should be replaced . If there ar e an y deposits of dirt or soot on the catalyst they should be cleaned with[...]
-
Page 12
Fire sparks but pilot does not light No gas to fir e, check isolators are open. Pipe work blockage, clean out. Air not fully purged, r e purge supply or wait longer . Spark earthing to metal work, reset ga p corr ectly . Block ed pilot, clean out internally . Pilot lights but then goes out Sev er e restriction in gas suppl y: clear obstruction. Fau[...]
-
Page 13
Section Content P age No 1.0 Important Notes 1 2.0 Clearances to Combustibles 1 3.0 V entilation & Room Size 2 4.0 Operating Instructions 3 5.0 Combustion Monitoring System 3 6.0 Cleaning 3 7.0 Ser vicing 4 8.0 List of Replacement Parts 4 9.0 Installation Details 4 10.0 Ser vice Histor y 4 The installation and Ser vicing of this fir e MUST only[...]
-
Page 14
Clearances to combustible materials Combustible materials are def ined as wood, fabrics, or other materials likel y to combust if exposed to flame. Generally , an y mate- rial, which is lik ely to discolour , melt or misshape when exposed to moderate heat, should be consider ed as a combustible mate- rial or surface. Clearance to the sides of the a[...]
-
Page 15
Classic models : The control knob is located on the low er right hand side of the outer case.It is marked as shown in figur e 6; Linear models : The control knob is located on the low er right hand side of the outer case. It is marked as shown in figur e 7; Fab models : The contr ol knob is located on the low er right hand side of the outer case. I[...]
-
Page 16
The appliance should be check ed on an annual basis to ensur e it is w orking safely and that ther e is no excessiv e build up of so ot. The frequency of service will depend on usage , but MUST be carried out at least once annually . Ser vicing must be carried out b y a competent person, such as a CORGI register ed installer . The Installation inst[...]