Go to page of
Similar user manuals
-
Postal Equipment
Soehnle 7711
29 pages 2.56 mb -
Postal Equipment
Soehnle 9115
92 pages 3.13 mb -
Postal Equipment
Soehnle 9240
28 pages 3.64 mb -
Postal Equipment
Soehnle 9220
24 pages 1.72 mb -
Postal Equipment
Soehnle cwe7745
13 pages 2.03 mb -
Postal Equipment
Soehnle 9320
40 pages 1.35 mb -
Postal Equipment
Soehnle 7850.02
12 pages 1.71 mb -
Postal Equipment
Soehnle 9222
12 pages 1.04 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Soehnle 9222, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Soehnle 9222 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Soehnle 9222. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Soehnle 9222 should contain:
- informations concerning technical data of Soehnle 9222
- name of the manufacturer and a year of construction of the Soehnle 9222 item
- rules of operation, control and maintenance of the Soehnle 9222 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Soehnle 9222 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Soehnle 9222, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Soehnle service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Soehnle 9222.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Soehnle 9222 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
FOR MEASURABLE SUCCESS Operating Manual COUNTING SCALE 9222 www .soehnle-pro f essional.com T rade, Commer ce and Industry[...]
-
Page 2
ENGLISH Counting Scale 9222 2 1. Genera l Inf or matio n P . 3 Applica tion P . 3 Saf e ty No tices P . 3 Cle aning P . 3 M aint enance and Ser vice P . 3 Note P . 3 War r anty/Liability P . 4 Specifica tions P . 4 Disposal P . 4 2. Usin g the Scales f or the Fi rst Ti me P . 5 Supplied Con ten ts P . 5 Assembling the Scales P . 5 Swit ching on/of [...]
-
Page 3
3 ■ Applic ation The Soehnle Pr of e ssional Count ing Scale 9 222 is designed f or weighing goo ds and calculat ing unit t otals. ■ Sa f ety N oti ces R ead the opera to r manual car efully be f or e using the equipmen t f or the f irs t time. It c ontains impor- tant in f ormat ion on the ins talla tion, co rr ec t use and maint enance o f th[...]
-
Page 4
ENGLISH Counting Scale 9222 4 ■ Wa rr an ty/Liab il ity If the supplied goods con tains a def ec t a t tribu table t o Soehnle Pro f essional, Soehnle Pro f essional shall be entitled t o r ec tif y the def ect or p r ovide a replac e- ment. R eplaced par ts shall become the p r oper ty of Soehnle Pr of e ssional. Should the r ec tif icat ion or [...]
-
Page 5
5 2. USING THE SCALES F OR THE FIR S T TI M E ■ Sup pl ied Cont ents • Scales • Platf orm • Wall power supply ■ Assem bli n g the Scal e s 1. R emov e the cover f r om the pla tf orm and place the platf orm on the scales. 2. Assemble the scales at the ap plicatio n point. 3. Use the adjus table legs and the spirit le vel t o ensure the s [...]
-
Page 6
ENGLISH Counting Scale 9222 6 01 13 12 24 PLU shor t cut k eys (to call up s to r ed unit weights dir ectly) 9 0 T o input numer ical values x 1 Input the r e f er ence weight (unit weight) Input the r e f er ence amoun t (unit t otal) A B T oggle key between 2 scales (inac tiv e) Change the display between gr oss, net and tar e weights ALARM Limit[...]
-
Page 7
7 Charge bat ter y Ne t weig ht Idle Ze ro re p ort PLU memo ry Sum t otal memor y ■ Displa y Symb ols Displa y in kilograms Displa y in grams Load above up per target weight Load below lower targe t weight T o tal weight R ef er ence weight o r amount Calculat ed unit t otal ■ Displa y NET kg g kg g Hi Lo A B C D PLU ACC[...]
-
Page 8
ENGLISH Counting Scale 9222 8 ■ Zero se tting 0 If af ter power ing up the scales there is no load on the scales bu t the display is no t zero, p r ess 0 . Possible zer o se t ting r ange –2%…+2% of the weighing r ange. The displa y shows . ■ Cal culati ng / Ded u ctin g the T are W eigh t Weig hin g with the ta re weigh t c alc ulate d •[...]
-
Page 9
9 • R emove the r ef erenc e pieces f r om the platf orm and wait brie fly un til the scales have calcula ted the unit weight. Other amounts plac ed on the scales will now also be count ed. Comp ensati ng fl uctuatin g weights Place o ther r ef erence p ieces on the scales. Pr ess t o calculat e the exac t unit weight. x 1 Cou ntin g with a known[...]
-
Page 10
ENGLISH Counting Scale 9222 10 Displa ying th e sum to tal • Pr ess . Deleti ng th e sum to tal in th e mem ory • Pr ess C . ■ Saving PL U (Prod u ct Look Up) PLUs ar e used t o s t or e inf ormatio n on par ts that ar e used r egularly , so tha t the data can be r etr ieved quickly f ro m the memory . The PLU number co ntains data o n the ta[...]
-
Page 11
11 ■ Pro g ramming t he T are Wei g ht as Sta n dar d • Place the tar e weight on the scales bef or e swit ching them on. • Swit ch on the scales. Con tinue as described in "Saving PL U (Pr oduct Look Up)". ■ Err or Me ssages Max. weighin g ran ge exceed ed > T ake the items o f f the scales Piep Zer o set ti ng no t possib le [...]
-
Page 12
ENGLISH Counting Scale 9222 12 Scales, System Solutions And Special Developments Soeh nle Pr of e ssional Gm bH & Co. K G M anf r ed-von-Ar denne-A llee 12 DE-71522 Backnang Phone +49 (0) 7 1 91 / 34 53 -0 F ax +49 (0) 71 91 / 3 4 53 -2 1 1 inf o@soehnle-pr of essional.com www.s oehnle-pro f essional.com All rights r eserved. © Soehnle Pr of e[...]