1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Soleus Air KFHHP-12-ID, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Soleus Air KFHHP-12-ID one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Soleus Air KFHHP-12-ID. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Soleus Air KFHHP-12-ID should contain:
- informations concerning technical data of Soleus Air KFHHP-12-ID
- name of the manufacturer and a year of construction of the Soleus Air KFHHP-12-ID item
- rules of operation, control and maintenance of the Soleus Air KFHHP-12-ID item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Soleus Air KFHHP-12-ID alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Soleus Air KFHHP-12-ID, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Soleus Air service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Soleus Air KFHHP-12-ID.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Soleus Air KFHHP-12-ID item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Wall Mounted Mini Split Heat Pump Air Conditioner OPERATING AND INSTALLATION MANUAL Model: KFIHP-09-ID / KFHHP-09-OD KFHHP-12-ID / KFHHP-12-OD Thank you for selecting Soleus Air. To ensure proper operation, please read this manual and keep it for future reference . Indoor Unit . Outdoor Unit .[...]

  • Page 2

    TABLE OF CONTENTS STRUCTURE AND OPERATION...……………………..……………………………………….....1-8 Name of Each Part …………………………………………………………….………..………...……1 The Instructions before Use……………………………………………………………………?[...]

  • Page 3

    - 1 - Structure and Operation ◆ Name of Each Part[...]

  • Page 4

    - 2 - ◆ The Instructions before Use Warning ★ Grounding: The unit must be properly grounded. ★ Disconnect the power when the unit is not being used for extended periods of time. ★ Don’t attempt to repair the air conditioner by yourself. There are no user replaceable parts. Please contact your authorized dealer. ★ If your air conditioner[...]

  • Page 5

    - 3 - ◆ The Instructions before Use ★ Set the room temperature appropriately. ★ Adjust the air flow and direction properly. When the air conditioner is running, you can press the SWING key on the remote control to adjust the guide louver and change the direction of air flow. ★ Close all doors & windows for efficient operation. ★ To av[...]

  • Page 6

    - 4 - ◆ Specification and Technical Data Model KFIHP-09-ID KFIHP-09-OD KFHHP-12-ID KFHHP-12-OD Function Cool / Heat Accessory Air Cleaner Cooling capacity (Btu/h) 9000 12000 Heating capacity (Btu/h) 9500 13000 Power Supply (V) 115V~ 208~230 Frequency (Hz) 60 Cooling/Heating rated current(A) 12/13.6 9/10 Cooling/Heating rated power(W) 1250/1450 17[...]

  • Page 7

    - 5 - ◆ Remote Control Operation Function-Remote control Note: • Don't drop the remote control. • Don't place the remote control in a location exposed to direct sunlight. • When the unit is restarted after stopped, it will au tomatically resume its last running mode, and the outdoor unit will start there after. TEMP+ TEMP- Button:[...]

  • Page 8

    - 6 - ◆ Remote Control Operation (Continued) Liquid Crystal Display. It shows all set contents. ON/OFF Button Press ON. Press OFF. T-ON Button. When pressing this b utton once, enter in to T-ON setting, the icon of T-ON flash, every press of TIME+, the time of T-ON will be increased 1min. When contin uously press 1 sec above, the tens placed on m[...]

  • Page 9

    - 7 - ◆ How to Insert Batteries 1. Remove the cover from the back of the remote control. 2. Insert the two batteries (T wo AAA dry-cell batteries). 3. Re-attach the cover. NOTE: • Don’t mix different batteries. • Remove batteries when not in use for a longtime. • The batteries can be used for about one year. • Keep remote at least 3.28 [...]

  • Page 10

    - 8 - ◆ Operation The general procedure: 1. Power the unit and a buzzer will sound. Power/Run in dication is red and the air conditioner is waiting to run. (Note: Once the air conditioner plugs to power supply or receives the signal of remote control, the buzzer will send out the desirable sound.) 2. Press ON/OFF button, Power/Run indication is g[...]

  • Page 11

    - 9 - Installation ◆ Installation Location Indoor Unit 1. The inlet and outlet should not be covered so that the outflow air can reach all parts of the room. 2. Install in a location from which the condensation wate r can be drained out conveniently and that is permitting easy connection with the outdoor unit. 3. Avoid a location where there is h[...]

  • Page 12

    - 10 - ◆ Electric Wiring 1. All the electric work must be done according to the wiring diagram. 2. Check for the correct voltage of the unit. 3. Don’t pull the power cord strongly. 4. The air conditioner must be safely grounded! Grounding wire must be connected to the building and done by the qualified personnel. In fixed circuit, th ere must b[...]

  • Page 13

    - 11 - ◆ Installation Dimension Diagram Important Notes  The installation must be done by trained and qualified service personnel. 212.6 inch 112.6 inch[...]

  • Page 14

    - 12 - ◆ Installation • Install the rear panel 1. Always mount the rear panel horizontally. Because the mouth of drainage pipe is at the left side and the left side of the rear panel is better to adjust slightly lower. 2. Fix the rear panel on the selected location with screws supplied with the unit. 3. Be sure that the rear panel has been fixe[...]

  • Page 15

    - 13 - ◆ Installation 4. Connect the Neutral wire of the power connection cables to the “ N (1) ” terminal of the terminal board, connect the Signal wire to the “2” terminal , and connect the live wire to the“3”terminal and connect the grounding wire to the “ ” terminal. 5. Reassemble the wiring cover and tighten the screw. 6. Rec[...]

  • Page 16

    - 14 - ◆ Install the Indoor Unit 1. When routing the piping and wiring from the left or right side of the indoor unit, cut off the taili ngs from the chassis in necessary (shown in Fig.4 (a), (b) and (c)). (1) Cut off the tailings 1 when routing the wiring only. (2) Cut off the tailings 1 and tailings 2 (or tailings 1, ta ilings 2 and tailings 3)[...]

  • Page 17

    - 15 - ◆ Install the Outdoor Unit • Install the connection pipe 1. Align the center of the piping flare with the valve. 2. Screw in the flare nut by hand and then tighten the nut with spanner and torque wrench refer to right figure. Tightening Torque Table Hex Nut Diameter (mm) Tightening Torque ( N.m ) Φ 6 15~20 φ 12 50~55 • Electric w[...]

  • Page 18

    - 16 - ◆ Install the Outdoor Unit • Air Purging and Leakage Test 1. Remove the flare nuts of charging end from gas valve. 2. Connect the charging hose in the middle to the vacuum pump, then Low-pressure (Lo) end should be connected to charging end of gas valve. (Shown in Fig. 9) 3. Open the vacuum pump to evacuate. When multi-meter indicates 1 [...]

  • Page 19

    - 17 - ◆ Test Operation and Check after Installation Test Operation 1. Before Test Operation (1) Do not switch on power before installation is finished completely. (2) Electric wiring must be connect ed correctly and s ecurely (3) Cut-off valves of the conn ection pipes should be opened. (4) All the impurities such as scraps m ust be cleared from[...]

  • Page 20

    - 18 - Care and Maintenance ◆ Care and Maintenance CAUTION: Turn power off and pull out the power cord b efore cleaning air conditione r. Never sprinkle water on the indoor u nit and the outdoor unit for cleaning because it can cause an electric shock. Volatile Liquid (e.g. thinner or gasoline) will damage the air condition er. (So wipe the units[...]

  • Page 21

    - 19 - ◆ Care and Maintenance (Continued) 3. Reinsert the filters Reinsert the filters along the direction of arrow, then cover the surface panel and clasp it. Check before Use 1. Be sure that nothing ob structs the air outlet an d intake vents. 2. Verify that the unit is properly grounded. 3. Always use new batteries. 4. Verify condenser is prop[...]

  • Page 22

    - 20 - ◆ Trouble Shooting Problem Trouble Shooting Sound of w ater flo w can be he ard during operation. This is caused by the refrigerant flowing inside the unit. Mist is emitted during cooling operation. Because the air of the room is cooled down rapidly. Creaking noise can be heard wh en start or stop the unit. This is caused by the expansion [...]

  • Page 23

    - 21 - ◆ Trouble Shooting Immediately discontinue using the unit and disconnect the pow er if any of the following occurs: Unusual noise can be heard during operation. Air switch or leakage protection switch often shuts down. Water is leaking from the unit. Electrical lines and power plug are very hot or smoking. Wind blowing from the outlet smel[...]

  • Page 24

    - 22 - Electrical Schematic Diagram ◆ Electrical Schematic Diagram (Indoor Unit) Please Insert Diagram in here.[...]

  • Page 25

    - 23 - ◆ Electrical Schematic Diagram (Outdoor Unit) Please Insert Diagram in here.[...]

  • Page 26

    - 24 - Warranty Soleus International Inc. warrants the accompanying Soleus Air Wall Mounted Mini Split Heat Pump Air Conditioner (KFIHP-09-ID/KFIHP-09-OD; KFHHP-12-ID/KFH HP-12-OD) to be free of defects in material and workmanship for the applications specified in its operation inst ruction for the period of labor and parts specified below. 5 YEARS[...]