Go to page of
Similar user manuals
-
Air Conditioner
Soleus Air GM-PAC-12E1HP
16 pages 1.87 mb -
Air Conditioner
Soleus Air SG-WAC-06ESE-F
17 pages 0.75 mb -
Air Conditioner
Soleus Air GB-WAC-06ESE-C
20 pages 2.63 mb -
Air Conditioner
Soleus Air MA-9000AH
19 pages 0.62 mb -
Air Conditioner
Soleus Air GM-PAC-12E1
16 pages 1.87 mb -
Air Conditioner
Soleus Air SG-TTW-10ESE
15 pages 2.15 mb -
Air Conditioner
Soleus Air SG-PAC-08E3 (KY-80)
16 pages 7.22 mb -
Air Conditioner
Soleus Air SG-TTW-10HC
18 pages 1.49 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Soleus Air KFHHP-18-ID, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Soleus Air KFHHP-18-ID one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Soleus Air KFHHP-18-ID. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Soleus Air KFHHP-18-ID should contain:
- informations concerning technical data of Soleus Air KFHHP-18-ID
- name of the manufacturer and a year of construction of the Soleus Air KFHHP-18-ID item
- rules of operation, control and maintenance of the Soleus Air KFHHP-18-ID item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Soleus Air KFHHP-18-ID alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Soleus Air KFHHP-18-ID, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Soleus Air service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Soleus Air KFHHP-18-ID.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Soleus Air KFHHP-18-ID item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
Wall Mounted Mini Split Heat Pump Air Conditioner OPERATING AND INSTALLATION MANUAL Model: KFHHP-18-ID / KFHHP-18-OD Thank you for selecting Soleus Air. To ensure proper operation, please read this manual and keep it for future reference . Indoor Unit . Outdoor Unit .[...]
-
Page 2
TABLE OF CONTENTS USE AND MAINTENANCE……………………………..…………………………………….....1-14 Precautions on Use …………………………………………………………………..……………1-3 Specifications and Technical Data…………………………………………………………………...[...]
-
Page 3
- 1 - Use and Maintenance ◆ Precautions on Use Carefully read the following precautions before use Warning ★ In case of malfunction (e.g. burnt smell), cut off the power supply immediately and then contact the Authorized Service Center (626-820- 1436). The malfunction continues, the air conditione r may be damaged. ★ To avoid ele ctric shock.[...]
-
Page 4
- 2 - ◆ Precautions on Use ★ Grounding: The un it must be properly grounded. ★ Set the room temperature appropriately. ★ Close all doors & windows for efficient operat ion. ★ Never block the air inlet or ou tlet of indoor and outd oor unit . ★ To avoid the possibility of fire. Never store chemical s or flamm able items within 3.28 f[...]
-
Page 5
- 3 - ◆ Precautions on Use ★ Adjust the ai r flow and direction properly. When the air c onditioner i s runni ng, you can p ress the SWING key on the remote control to adjust the guide louver and change th e direction of air flow. ★ To avoid in jury or dam age, never stick your fingers or any other object in to the unit. ★ To avoid harm to [...]
-
Page 6
- 4 - ◆ Specifications and Technical Data Model KFHHP-18-ID / KFHHP-18-OD Function Heating and Cooling Cooling capacity(BTU/hr) & (Watts) 18000 / 5300 (1400- 6000) Heating capacity(BTU/hr) & (Watts) 20000 / 6000 (1100- 7000) Rated voltage 208-230V ~ Rated Frequency 60Hz Cooling/Heating rated current(A) 10.6/10.6 Cooling/Heating rated po[...]
-
Page 7
- 5 - ◆ Instructions for Use Principle and Special Functions during Cooling Mode Principle: The air conditi oner absor bs heat from indoor air a nd transm its it outdo ors for disc harge, hence to dec rease the i ndoor ambient temperature. The cooling ca pacity decreases with the rise of outd oor ambient temperature. Anti-freeze Function: If the [...]
-
Page 8
- 6 - ◆ Description of Air-Conditioner Components (1) Front Panel (2) Guide Louver (3) Remote Sensor (4) Wall Pipe (5) Wrapping Tape (6) Drainage hose (7) Connection pipe[...]
-
Page 9
- 7 - ◆ Remote Control Operation Function-Remote control Note: • Don't drop the remote control. • Don't place the remote control in a location exposed to direct sunlight. • When the unit is restarted after stopped, it will au tomatically resume its last running mode, and the outdoor unit will start there after. TEMP+ TEMP- Button:[...]
-
Page 10
- 8 - ◆ Remote Control Operation (Continued) Liquid Crystal Display. It shows all set contents. ON/OFF Button Press ON. Press OFF. T-ON Button. When pressing this b utton once, enter in to T-ON setting, the icon of T-ON flash, every press of TIME+, the time of T-ON will be increased 1min. When contin uously press 1 sec above, the tens placed on m[...]
-
Page 11
- 9 - ◆ How to Insert Batteries 1. Remove the cover from the back of the remote control. 2. Insert the two batteries (T wo AAA dry-cell batteries). 3. Re-attach the cover. NOTE: • Don’t mix different batteries. • Remove batteries when not in use for a longtime. • The batteries can be used for about one year. • Keep remote at least 3.28 [...]
-
Page 12
- 10 - ◆ Cleaning and Maintenance • Be sure to cut off the power supply before cleani ng the air conditioner; otherwise electric shock might occur. • Liquids on the air conditioner may cause the risk of el ectric shock. Make sure not to spray wash your air conditioner in any case. • Volatile liquids such as thinner or gasoline will cau se d[...]
-
Page 13
- 11 - ◆ Cleaning and Maintenance ③ Installing the air filter Mount the air filter in the direction of the arrows. Then, clamp the cover of front panel securely. Check before Seasonal Use ① Check the air inlet/outlet on indoor and outdoor u nits for any blockage. ② Check the grounding cable for reliability. ③ Check the batteries of remote[...]
-
Page 14
- 12 - ◆ Trouble-Shooting Do not repair by yourself. Incorrect repair may cause electric shock or fire, so please contact the Authorized Service Center for professional repair. Fault Cause Analysis Air conditioner does not ru n upon immediate restart after a stop. To protect the air conditione r upon immediate restart after a stop, the microcompu[...]
-
Page 15
- 13 - ◆ Trouble-Shooting Fault Cause Analysis Air conditioner does not ru n. • Power failure ? • Circuit protection device tripped? • The voltage is to o high or too low? ( Refer to Page 15). (To be tested by professional technicians). • Timer function is correctly used? ( Refer to Page 7). Air conditioner is poor in cooling (or heating)[...]
-
Page 16
- 14 - ◆ Trouble-Shooting Fault Cause Analysis No air blows out from indoor un it. • When the temperature of i ndoor heat exchanger is low during heating process, the indoo r unit will stop blowing to prevent blowin g of cold air (within 3 minutes). • Under dehum idify m ode, the fan of the in door unit might be stopped to pr event evaporatio[...]
-
Page 17
- 15 - Installation Services ◆ Precautions on Installation Important Caution 1. The air-conditioning unit m ust be installed by profession al technicians in accordance with the state and local codes. 2. Contact the local installation and service agency b efore installation. 3. For relocation of the air conditioner to another pos ition, please con[...]
-
Page 18
- 16 - ◆ Precautions on Installation 4. Ensure safe grounding and the gr ounding wire shall b e connected with the special groundin g equipment of the building and m ust be instal led by profe ssional t echnician s. In the fixed line there mu st be an electrical leakage protection switch and an air switch w ith sufficient capacity. The air switch[...]
-
Page 19
- 17 - ◆ Installation Dimension Drawing[...]
-
Page 20
- 18 - ◆ Install Indoor Unit Installing Wall-Mounting Frame 1. Level with plumb line or spirit level. As the drain outlet is on left side, it is better that the left side shall be lower when adjusting the wall-mounted board. 2. Use screws to secure the wall-mounting frame on the wall. 3. After installation is completed, manually pull the wall-mou[...]
-
Page 21
- 19 - ◆ Install Indoor Unit Notes: If the connecting cable is not long enough, please contact your distributor for a piece of special cable with sufficient length. No joints are allowed in the middle of the cable. • Be sure to connect the cable correctly. Incorrect connection will cause fault to some electrical parts. • Tighten the terminal [...]
-
Page 22
- 20 - ◆ Install Outdoor Unit Power Cable Connection 1. Remove the handle at t he right side plate of t he outdoor unit (one screw). 2. Remove the ca ble clamp, conn ect the power connection cable with the terminal at the row of connection and make the connection. The fitting lin e distributing must be consistent with the indoor unit. 3. Use cabl[...]
-
Page 23
- 21 - ◆ Install Outdoor Unit Check Items After Installation Check Items Problems Owing to Improper Installation Is the installation reliable? The unit may drop, vibrate or make noises Has the refrigerant gas leakage been checked? May cause unsatisfactory cooling (heating) effect Is the thermal insulation of the unit suffici ent? May cause conden[...]
-
Page 24
- 22 - Electrical Schematic Diagram ◆ Electrical Schematic Diagram (Indoor Unit)[...]
-
Page 25
- 23 - ◆ Electrical Schematic Diagram (Outdoor Unit)[...]
-
Page 26
- 24 - Warranty Soleus International Inc. warrants the accompanying Soleus Air Wall Mounted Mini Split Heat Pump Air Conditioner (KFHHP-18-ID/KFHHP-18-OD) to be free of defects in material and workmanship for the applications specified in its operation instruc tion for th e period of parts specified below. 5 YEARS FOR COMPRESSOR 1 YEAR FOR OTHER CO[...]