Go to page of
Similar user manuals
-
Air Conditioner
Soleus Air SG-PAC-08E3 (KY-80)
16 pages 7.22 mb -
Air Conditioner
Soleus Air PH1-10R-03
17 pages 0.86 mb -
Air Conditioner
Soleus Air KFTHP-09
27 pages 2.03 mb -
Air Conditioner
Soleus Air SG-TTW-12HC
20 pages 1.86 mb -
Air Conditioner
Soleus Air KFHHP-12-OD
26 pages 1.28 mb -
Air Conditioner
Soleus Air PH4-10R-01
16 pages 1.32 mb -
Air Conditioner
Soleus Air KY-80G
15 pages 1.03 mb -
Air Conditioner
Soleus Air SG-WAC-05SM
12 pages 0.87 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Soleus Air KY-32U, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Soleus Air KY-32U one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Soleus Air KY-32U. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Soleus Air KY-32U should contain:
- informations concerning technical data of Soleus Air KY-32U
- name of the manufacturer and a year of construction of the Soleus Air KY-32U item
- rules of operation, control and maintenance of the Soleus Air KY-32U item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Soleus Air KY-32U alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Soleus Air KY-32U, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Soleus Air service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Soleus Air KY-32U.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Soleus Air KY-32U item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
KY-32U Portable Air Conditioner User's Manual - Cooling - Dehumidifying - Fan[...]
-
Page 2
TABLE OF CONTENTS INTRODUCTION ..................................................................................................................... 1 IMPORTANT SAFEGUARDS ................................................................................................... 1 PACKAGE CONTAINS: ..........................................................[...]
-
Page 3
INTRODUCTION Thank you for purchasing the Soleus Air KY32U portable air-conditioner. This unit is designed for improving living and working comfort by providing cooling, dehumidi lying and fan functions only with a minimum installation required. With its whisper quite operation and attractive design, you will enjoy the convenience and comfort that [...]
-
Page 4
NAMES OF PARTS control panel upper air outlet handle lower air inlet grille Front View Signal Receptor BackView Exhaust Duct Terminal upper air inlet grill with filter continuous drainage water tank power cord hot air exhaust outlet lower air inlet grille -2-[...]
-
Page 5
Exhaust Duct Unit Terminal End Exhaust Du_ Window Kit Adaptor Window Kits INSTALLATION BEFORE USE 1) Condensate Water Tank Float Lid You must install the water tank float lid before first use of the portable air conditioner following these procedures: a) Hold the water tank and draw it out slowly. b) Remove water tank float lid and packing material[...]
-
Page 6
water tank float lid should be able to move up and down freely after correct installment. d) Insert the complete water tank back to the air conditioner unit. 2) ExhaustDuct Fig. 1 c) When you use the unit as an air conditioner, the hot exhaust air must be directed out of the rooln. The exhaust duct is used to allow the hot air out. DO NOT 1NSTALL O[...]
-
Page 7
t) Use screws on the window kit extension if necessary. NOTE: When using the window kit on a window or sliding door it will cause the window or sliding door not to be properly closed and locked. Additional security measurements should be taken. CONTROL PANEL AND LCD DISPLAY CONTROL PANEL Fan spef>d _ue¢{on Pow÷r on!off bu{_on MODE LCD DISPLAY [...]
-
Page 8
Control Panel Functions 1) Power On/Off Control Starts or Stops the Unit 2) Mode Control Select the functions of the unit for: Fanonly Air ConditioningonlyDehumidifyingonly Auto Control 3) Fan Speed Control Select the Pan speed for: High Medium Slow 4) Temperature Setting Control Select the desired temperature setting by pressing either ? or _/key[...]
-
Page 9
OPERATION USING CONTROL PANEL 1) Cooling Operation a) Be sure that the drain tank is properly placed in the unit. b) Install the exhaust duct properly. c) Plug the Power Cord to the power outlet. d) Turn on the unit bypressing the On!OffButton on the control panel. For Manual Mode: Press the Mode Button until the snowflakes and _Cool_ appears on th[...]
-
Page 10
NOTE: Do not use the exhaust duct when the unit is running at dehumidifying model. You must remove the exhaust duct from the unit. When the unit is running at dehumidifying mode, the Pan speed cannot be adjusted. Keep the windows and the doors closed to aid the effectiveness of the unit in removing the moisture from the room. 3) Fan Operation a) Pl[...]
-
Page 11
REMOTE CONTROLLER LCD DISPLAY MODE KEY TEMPERATURE KEY FAN SPEED KEY TIMER KEY TIME ADJUSTMENT KEY DEHUMIDIFYING KEY TRANSMITTING KEY AUTO MODE KEY ON/OFF KEY SLEEPING MODE KEY l) 2) Set Clock a) Press On!Off key to turn on the remote controller b) Press left side (Hour) or right side (Minute) of the Time Adjustment key until the LCD displays the c[...]
-
Page 12
d) Press the Fan Speed key until the LCD displays the desired fan speed. e) Press the Transmit key. NOTE: When pressing the Mode Key, the LCD displays "COOL", "FAN" AND "HEAT". This KY-32U unit does not have a heating function. 3) DehumidifyingOperation a) Press the On!Offkey to turn on the remote controller b) Press D[...]
-
Page 13
7) Sleep Mode a) Press the On!Offkey to turn on the remote controller. b) Press the Sleep key. "Sleep" will appear on the LCD display. c) Press either/ of V key of the Temperature key until the LCD displays the desired temperature. d) Press the Fan Speed keyuntil the LCD displays the desired Pan speed. e) Press Timer and Time Adjustment [...]
-
Page 14
mode, condensate water does not go to the internal water tank. Condensate is discharged by gravity through the drainage tubing to either an external tank (not provided) or to a condensate water pump device (Optional Item). When the unit is operating on continuous drainage mode, it can operate con- tinuously without periodic stops to empty the water[...]
-
Page 15
maintenance activities. 1) Clean or replace filter If the air filter is blocked with a lot of dust, the airflow volume will reduce. It is recommended to clean the filter once every two weeks or as needed. filter cover hooks a) Push down the two tabs on the filter cover and pull outwards to remove the entire filter and cover. b) Carefully, take the [...]
-
Page 16
TROUBLESHOOTING PROBLEM Unit does not operate Unit does not cool room In dehumidifying mode, no cool air coming out LCD window shows "E4" Noise or vibration Water is leaking from unit LCD window show "E 1" POSSIBLE CAUSE Unit is unplugged Drain tank is full Water tank not installed correctly Air exhaust is clogged Timer is on Th[...]
-
Page 17
TECHNICAL SPECIFICATIONS MODEL COOLING CAPACITY DEHUMIDIFYING CAPACITY COOLING POWER DEHUMIDIFYING AIR FLOW VOLUME POWER SOURCE SOUND PRESSURE LEVEL NET WEIGHT BODY DIMENSIONS PACKAGE REFRIGERANT WATER TANK VOLUME KY-32U 12,000 BTU/H 1,870 OZ/DAY 1.61 HP 1.1 HP 13,414 CSF (225 CFM) ll5V60HZ 10 AMPS 1200 WATTS 52db 100 34 x 18 x 15 Inch 45 x 21 x 19[...]
-
Page 18
ELECTRIC PRINCIPLE DRAWING KY-32U -16-[...]
-
Page 19
WARRANTY ONE YEAR LIMITED WARRANTY Soleus International Inc. warrants the accompanying Soleus Air KY-3 2U Mobile Air Conditioner to be free of defects in material and workmanship for the applications specified in its operation instruction for a period of ONE (1) year from the date of original retail purchase in the United States or Canada. If the a[...]
-
Page 20
LCDI POWER CORD AND PLUG This air conditioner is equipped with an LCDI (Leakage Current Detection and Interruption) power cord and plug as required by US National Electric Code 440.65. This cord consists of a length of shielded flexible cord with no termination on the load side and a LCDI attachment plug on the line side. The LCDI power cord and pl[...]