Go to page of
Similar user manuals
-
Air Conditioner
Soleus Air SG-TTW-09HC-26
17 pages 4.64 mb -
Air Conditioner
Soleus Air KFHHP-22-OD
26 pages 1.34 mb -
Air Conditioner
Soleus Air GL-PAC-08E4
14 pages 11.67 mb -
Air Conditioner
Soleus Air SG-TTW-10HC
18 pages 1.49 mb -
Air Conditioner
Soleus Air SG-CAC-12SE
23 pages 0.86 mb -
Air Conditioner
Soleus Air SG-PAC-08E3 (KY-80)
16 pages 7.22 mb -
Air Conditioner
Soleus Air GM-PAC-10E2
18 pages 5.95 mb -
Air Conditioner
Soleus Air KY-80
15 pages 1.03 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Soleus Air KY-34, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Soleus Air KY-34 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Soleus Air KY-34. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Soleus Air KY-34 should contain:
- informations concerning technical data of Soleus Air KY-34
- name of the manufacturer and a year of construction of the Soleus Air KY-34 item
- rules of operation, control and maintenance of the Soleus Air KY-34 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Soleus Air KY-34 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Soleus Air KY-34, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Soleus Air service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Soleus Air KY-34.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Soleus Air KY-34 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
Port able Air Conditioner , Dehumidifier ,Heater and Fan utilizing Heat Pump T echnology OWNER'S MANUAL Model # KY-34 Please read owner ’ s manual carefully before operating unit. 3046364 Sales Inquiries: 800-934-9194[...]
-
Page 2
2 T ABLE OF CONTENTS INTRODUCTION ............................................................................................................................................................. 3 IMPOR T ANT SAFEGUARDS .....................................................................................................................................[...]
-
Page 3
3 INTRODUCTION Thank you for purchasing the Soleus Air KY-34 14,0 00 BTU Portable Air Conditioner and Heater . This unit is designed to improve indoor livi ng and working co mfort by providin g cooling, dehumidifying, heating, and ventilation with minimal installation. This multi-functional unit operates as an air conditioner , dehumidifier , heate[...]
-
Page 4
4 IMPORT ANT SAFEGUA RDS Before installing and using your portable air conditioner a nd heater , it is important that you read this owner’ s manual carefully . Store this manual in a safe place for future reference. This instruction manual is used for guidance and does not form part of a contract. It reserves the right to make technical changes w[...]
-
Page 5
LCDI POWER CORD AND PLUG This air conditioner is equipped with an LCDI (Leakag e Current Detection and Interruption) power cord and plug as required by US National Electric Code 440.65. This cord consists of a length of shielded flexible cord with no termination on the load side and a LCDI attachment plug on the line side. The LCDI power cord and p[...]
-
Page 6
PRODUCT DIAGRAM FRONT A. Control panel B. V ertical air louvers C. Air outlet D. Horizontal air lo uvers E. Casters F. Cable (power cord and plug) BACK A. Hot air outlet grill B. Lower air inlet grill ACCESSORIES Flexible exhaust hose with ad apters • 3-piece set • stretches from 14 1/4” to 60 5 /8” (36cm to 150cm) Window exhaust adapter Ad[...]
-
Page 7
INST ALLA TION SELECTING THE LOCA TION Place the unit in a flat location where the air outlets are not obstructed. Pl ace the unit at least 20” (50cm) away from a wall or other obstacle. MOUNTING THE EXHAUST HOSE Slide the square end of the ex haust duct over the hot air outlet on the back of the unit. The exhaust hose should be k ept as short an[...]
-
Page 8
WINDOW KI T INST ALLA TION The window kit is designed to fi t into most standard vertical and horizont al windows. However , it may be necessary to modify some aspects of the installation pro cess for certain window types. 1. Open the window or sliding door and adjust the length of the window kit to f it the opening. Mark and cut down a single pane[...]
-
Page 9
CONTROL P ANEL AND MUL TI-COLOR DISPLA Y CONTROL P ANEL F AN SPEED Button During the modes of cooling, heating and fanning, press this button to choose high, medium or low fan speed. In dehumidifying mode, this butt on is inoperable. SWING Button Press this button to oscillate t he vertical louvers or to stop oscillation. ∨ Button This button dec[...]
-
Page 10
10 CONTROL P ANEL FUNCTIONS ON/OFF BUTTON Starts or stops the unit. MODE BUTTON Press to select the operating mode: Fan Mode Air Conditioning Mode Heating Mode Dehumidifying Mode Auto Mode F AN BUTTON Press to select the fan speed: High, Medium, and Low . The fan speed can be visually distinguished by the number of the digital air segme nts (follow[...]
-
Page 11
the lowest and the fan speed at the highest. Reduc ing the length of the exhaust hoses, insulating the exhaust hoses, and keeping direct sunlight to a mi nimum will also improve the cooling ef ficiency . DEHUMIDIFYING 1. Properly install the exhaust hoses. 2. Plug the power cord into a grounded outl et. 3. T urn on the unit by pressing the On/O ff [...]
-
Page 12
SLEEP MODE (This mode can only be programmed from the remote control.) 1. The air conditioner will need to be in operation. 2. Press the Sleep button. The “ ” icon appears on the multi-color display . 3. The fan motor runs at low speed. 4. When in cooling mode, the temperature will increase 1 ° F per hour during the fir st two hours. Then the [...]
-
Page 13
W A TER DRAINAGE When the unit is in cooling mode, unwanted water is extracted from the air . Most of this water is used to cool the unit and make it run more efficiently . When the unit is used in extremely humid environments, water will collect in a water container at the bottom of the unit. When the water container is full, the compressor will s[...]
-
Page 14
MAINTENANCE Always turn off and unpl ug the unit before cleaning to avoid electrical shock. CLEANING THE HO USING Wipe the surface of the unit with a soft, damp cloth. Do not use abrasive che m icals or detergents to clean the surface of the unit, as the unit may become scratched or damage d. Avoid direct exp osure to sunlight as this may change th[...]
-
Page 15
TROUBLESHOOTING Before seeking repair or service, please check the following: PROBLEM POSSIBLE CAUSE REMEDY Is the unit plugged in? Securely plug the power cord i nto the wall outlet. Is the main power supply on? Reestablish the main power supply . Is the water container full indica tor light on? Empty the water container . Unit does not operate or[...]
-
Page 16
16 TECHNICAL SPECIFICA TIONS MODEL PH1-14 R-03 KY-34 PH 1-10R -03 Cool i ng Capa city 14,000 BTU/Hr 12,000 BTU/Hr 10,000 B TU/Hr Heating Capacity 14,200 BTU/Hr 12,200 BTU/Hr 10,200 BTU/Hr Dehumidifying Capacity 65 pts/day 63 pts/day 60 pts/day Cooling 1390 W 1340 W 1 180 W Power Consumption Heating 1 180 W 1090 W 1000 W Air Flow V olume 328CFM 280C[...]
-
Page 17
17 W ARRANTY One Y ear Limited W arranty Soleus International Inc. warrants the accompanying Sole us Air KY-34 to be free of defects in materia l and workmanship for the applications specified in its operation instruction f or a period of ONE (1) year from the date of original retail purchase in the United S tates. If the unit exhibits a defect in [...]