A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Soleus Air PE7-10R-03, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Soleus Air PE7-10R-03 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Soleus Air PE7-10R-03. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Soleus Air PE7-10R-03 should contain:
- informations concerning technical data of Soleus Air PE7-10R-03
- name of the manufacturer and a year of construction of the Soleus Air PE7-10R-03 item
- rules of operation, control and maintenance of the Soleus Air PE7-10R-03 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Soleus Air PE7-10R-03 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Soleus Air PE7-10R-03, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Soleus Air service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Soleus Air PE7-10R-03.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Soleus Air PE7-10R-03 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
© 2012Soleus Air International Portable Air Conditioner with Evaporative T echnology PE7-10R-03 Operating Instructions Model No. PE7-10R-03 3046364[...]
-
Page 2
Thank you for choosing a Soleus Air Portable Air Conditioner. This owner’s manual will provide you with valuable informati on necessary for the proper care and main tenance of your new product. Please take a few moments to thoroughly read the instructions and familia rize yourself with all the opera- tional aspects of your new Soleus Air Portable[...]
-
Page 3
SPEC IFICA T IONS • The cooling capacity is m easured at an am bient temperature of DB 86 °F, WB 78 °F. • Noise level is measured at a distance of 3.28 ft away from the front of the unit, when the unit is in cooling mode. • Power consum ption is m easured whe n the fan runs at the hi ghest speed setting. • These specifications are for ref[...]
-
Page 4
NOTE: Actual product design may differ slightly from images below. 4 FRONT A. Control panel B. Vertical air louvers C. Air outlet D. Horizontal air louvers E. Casters F. Power Cord & Plug BACK A. Hot air outlet grill B. Lower air inlet grill ACCESSORIES Flexible exhaust hose with 2 adapters • 3-piece set • stretches from 14 1/4” to 60 5/8[...]
-
Page 5
5 SELECTING THE LOCATION Place the unit in a flat location where the air out- lets are not obstructed. Place the unit at least 20” (50cm) away from a wall or other obstacle. MOUNTING THE EXHAUST HOSE Slide the square end of the exhaust duct over the hot air outlet on the back of the unit. The exhaust hose should be kept as short and straight as p[...]
-
Page 6
This air conditioner is equipped with an LCDI (Leakage Current Detec tion and Interruption) power cord and plug as required by US National Electric Code 440.65. This cord consists of a length of shielded flexible cord with no termination on the lo ad side and a LCDI attachm ent plug on the line side. The LCDI power cord and plug will remove the sup[...]
-
Page 7
WINDOW KIT INSTALLATION The window kit is designed to fit into most standard vertical and horizontal windows, as well as some sliding glass doors. However, it may be necessary to modify some aspects of the installation process for certain window types. Open the window or sliding door and adjust the length of the window kit to fit the opening. If th[...]
-
Page 8
8 NOTE: The Portable Air Cond itioner above may differ from the unit de scribed in th is manual. The above direction s and images show general directions for all Soleus Air single hose portable air conditioners. WINDOW KIT INST ALLA TION[...]
-
Page 9
9 CONTROL P ANEL & OPERA TION 1) Power On and Off - Press the POWER button once to manually turn the unit on. Press the POWER button once more to turn the unit off. 2) Mode Selection - Press the MODE Button repeatedly to cycle between the diffe rent modes: Air Conditioner and Dehumidifier. 3) Fan Speed Control - Press the FAN Button to cycle th[...]
-
Page 10
OPERA TING THE UNIT USING THE CONT ROL P ANEL Air Conditioner Mode 1) Install the exhaust hose and window kit properly (see pages 7 & 8). 2) Plug the Power Cord into an electrical outlet. 3) Turn on the unit by pressing the POWER button on the control panel. 4) Press the ▲ or ▼ buttons until the d esired room temp erature appears on the con[...]
-
Page 11
Emergency Condensate Holding Tank When the room temperature is low and the indoor hum id ity is high, the air conditioner may not be able to evaporate some of the moisture fast enough. W hen this happens, the water will accumulate in an emergency condensate tank inside the unit. Once the emergency conde nsate tank is full, the un it will automatica[...]
-
Page 12
REMOTE CONTROL TIMER/TEMP INCREASE FAN SPEED POWER BUTTON TIMER BUTTON TIMER/TEMP DECREASE SLEEP MODE (not available on this model) MODE BUTTON °F/°C SWING (LOUVER OSCILLATION) 12 1) Power On and Off - Press the ON/OFF button on the remote to turn the unit on or of f. 2) Mode Selection - Press the MODE Button repeatedly to cycle betwee n the diff[...]
-
Page 13
MAINTENANCE Note: Make sure power is off and the power cord is not plugged into an el ectrical outlet prior to performing any maintenance on the unit. Clean or replace filter - If the air filter is blocked with a dust, the airflow volum e may reduce. It is recommended to clean the filter onc e every two weeks or as needed. 1) Remove the filter from[...]
-
Page 14
W ARRANTY One Year Limited Warranty Soleus International Inc. warrants the ac companying Soleus Air Portable Air Cond itioner to be free of defects in mate- rial and workmanship for the applications specified in its operation instruction for a period of ONE (1) year from the date of original retail purchase in the United States. If the unit exhibit[...]