Soleus Air SG-PAC-10E2 (KY-101) manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Soleus Air SG-PAC-10E2 (KY-101), along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Soleus Air SG-PAC-10E2 (KY-101) one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Soleus Air SG-PAC-10E2 (KY-101). A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Soleus Air SG-PAC-10E2 (KY-101) should contain:
- informations concerning technical data of Soleus Air SG-PAC-10E2 (KY-101)
- name of the manufacturer and a year of construction of the Soleus Air SG-PAC-10E2 (KY-101) item
- rules of operation, control and maintenance of the Soleus Air SG-PAC-10E2 (KY-101) item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Soleus Air SG-PAC-10E2 (KY-101) alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Soleus Air SG-PAC-10E2 (KY-101), and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Soleus Air service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Soleus Air SG-PAC-10E2 (KY-101).

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Soleus Air SG-PAC-10E2 (KY-101) item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    10,000 BTU Portable Air Conditioner Operating Instructions Model No. 6 G-PAC-10E2  .<  V.121010[...]

  • Page 2

    Thank you for choosing a Sole us Air Powered by Gree Portable Air Conditioner. This owner’s man- ual will provide you with valuable information necessary for the proper care and maintenance of your new product. Please take a few moments to thoroughly read the instructions and familiarize yourself with all the operational aspects of your new Porta[...]

  • Page 3

    LCDI POWER CORD AND PLUG This air conditioner is equipped with an LCDI (Leakage Current Detection and Interruption) power cord and plug as required by US National Electric Code 440.65. This cord consists of a length of shielded flexible cord with no termination on the load side and a LCDI attachment plug on the line side. The LCDI power cord and pl[...]

  • Page 4

    INCLUDE P ARTS INCLUDED Window Exhaust Adapter A S crew (7 ) Exhaust Hose Window Exhaust Adapter C Adjustable Window Slider (3) Ho se clip(2) Rubber plug Battery (AAA.1.5V) INCLUDE Window Exhaust Adapter B SUGGESTED TOOLS FOR WINDOW P ANEL INST ALLA TION 1. Screwdriver(medium size Phillips) 2. T ape measure or ruler 3. Knife or scissors 4. Saw (In [...]

  • Page 5

    1, Control panel and display l LJKW 2, Remo W e control signal receiver window 3, Handl H 4, Remote controller box 5, Air outlet 6, V ertical louvers 7, Horizontal louvers 8, Wheel 9, Air inlet 10, Grille 11, Air outlet 12, Air inlet 13,Power cord hook 14, Power cord 1 5, Window exhaust adapte r A 16, Exhaust hose 17, Window exhaust adapter 18, Win[...]

  • Page 6

    SP ECIFICA TIONS x The cooling ca pacity is measured at an am bient temperature of DB 95 °F, WB 83 °F. x Noise level is measured at a distance of 3.28 ft away from the front of the unit, when the unit i s in cooling mode. x Power consumption is m easured when the fan runs at the highest s peed setting. x These specifications are for r[...]

  • Page 7

     Attach the hooks to the back of air conditioner with the screws. hook screw  Wind the power cord D round the power cord hooks.  INSTALLATION OF THE POWER CORD HOOK [...]

  • Page 8

    P ARTS & WINDOW KIT ASSEMBL Y PARTS EXHAUST HOSE & ADAPTERS ASSEMBLY & INSTALLATION INSTALLATION When the unit is operating as an air conditioner or dehumidifier, the window kit a nd exhaust hose must be installed. When the unit is operating in fan mode, the window ki t and exhaust hose do not need to be installed . MOUNTING THE EXHAUST[...]

  • Page 9

    SINGLE HOSE WINDOW KIT INSTALLATION When installing the exhaust hose, try and keep it as flat as possible. The less angles and bends in the hose, the better the unit will perform. If bending or an angle is necessary , use single 90 ° angles like the pictures above. Multiple bends will decrease performance and efficiency  This installation is OK[...]

  • Page 10

    CONTROL P ANEL & DISPLA Y When pressing key is valid, buzzer makes a sound, indicated light indicates relevant state, system will last for 2 seconds. OPERATING INSTRUCTIONS l. 3. MODE Button 4. Fan 6 peed When the unit is running in Cool or F a n mode, press the Fan speed Button to select the fan speed in High, Middle, Low , Auto. In cool mode,[...]

  • Page 11

    HOW TO USE THE REMOTE CONTROL For good receive, the distance between operator and the unit no more than 5 meters. Point t he remote control towards the units signal receiver window A . n o t t u b d e r i s e d e h t s s e r p d n a beep will sound when the unit re- ceives the signal. blocks the signal receiver window . CAUTION its operation. If ne[...]

  • Page 12

    1) Power On and Off - Press the ON/OFF (POWER) button once to manually turn the unit on. Press the Power button once more to turn t he unit off. When you m anually power the unit on and off by pressing the ON/OFF button, the preset timer will be cancelled. 2) Mode Selection - P r ess t h e MO DE Button re peatedly to c y cle betwee n t h e diffe re[...]

  • Page 13

    5) Auto-on Timer: When the air conditioner is off, it can be set to autom atically turn on in 30 minutes to 24 hours at the previous set mode and fan setting. To set the Auto-on Tim er, press t he TIMER button on t he unit or remote control. Each touc h of the +/- buttons on the remote will change the timer setting in 30 minute increments (.5 hours[...]

  • Page 14

    When the temperature or humidity is too high, the air conditioner may not be able to evaporate all of the water as quickly as needed. All moisture that is unable to be evaporated is p laced in a small bank up water tank in- side the unit. When this tank is com pletely full, an alarm will sound, the compressor will shut off, and the bucket full icon[...]

  • Page 15

    MAINTENANCE Note: Make sure power is off and the power cord is not plugged into an electrical outlet prior to performing any maintenance on the unit. Clean or replace filter - If the air filter is blocked with a dust, the airflow volum e may reduce. It is recommended to clean the filter once every two weeks or as needed. 1) Remove the filter from t[...]

  • Page 16

    PROBLEM The Air Conditioner will not start POSSIBLE CAUSES The air conditioner is unplu gged or not connected well. The fuse is blown/circuit breaker is tripped. Power Failure The current interrupter device is tripped. SOLUTIONS x Make sure the air conditioner plu g is pushed completely into the out- let x Check the house fuse/ci rcuit breake[...]

  • Page 17

    PROBLEM The LCD Display is showing “E5” POSSIBLE CAUSES Low Voltage Protection SOLUTIONS x Unplug for 10 minutes and then turn on the unit. If “E5” is still dis- played, contact customer service. TROUBLESHOOTING (CONT .) The LCD Display is showing “H8” The backup water tank is full x Drain the water tank x If the “H8” LV st[...]

  • Page 18

    W ARRANTY One Year Limited Warranty Soleus International Inc. warrants the accompanying Soleus Air Powered by Gree Portable Air Conditioner to be free of defects in material and workmanship for the applications specified in its operation instruction for a period of ONE (1) y ear from the date of original retail purchase in the United States. If the[...]