Solid State Logic XLogic Delta Solid State Logic XLogic Delta-Link MADI HD manual
- Read online or download the manual
- 32 pages
- 0.86 mb
Go to page of
Similar user manuals
-
Radio
Solid State Logic LINK MADI HD
32 pages 0.82 mb -
Computer Hardware
Solid State Logic 82S6MC120A
28 pages 2.22 mb -
Music Mixer
Solid State Logic 82S6DUA20C
127 pages 4.21 mb -
Speaker
Solid State Logic 82S6XL090A
30 pages 0.41 mb -
Stereo Receiver
Solid State Logic One Stop Vocal Processing Plug-in Vocalstrip
21 pages 0.82 mb -
Stereo Receiver
Solid State Logic Vocalstrip
21 pages 0.79 mb -
Stereo Equalizer
Solid State Logic DUENDE
29 pages 1.05 mb -
Computer Hardware
Solid State Logic MX4
19 pages 3.93 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Solid State Logic XLogic Delta Solid State Logic XLogic Delta-Link MADI HD, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Solid State Logic XLogic Delta Solid State Logic XLogic Delta-Link MADI HD one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Solid State Logic XLogic Delta Solid State Logic XLogic Delta-Link MADI HD. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Solid State Logic XLogic Delta Solid State Logic XLogic Delta-Link MADI HD should contain:
- informations concerning technical data of Solid State Logic XLogic Delta Solid State Logic XLogic Delta-Link MADI HD
- name of the manufacturer and a year of construction of the Solid State Logic XLogic Delta Solid State Logic XLogic Delta-Link MADI HD item
- rules of operation, control and maintenance of the Solid State Logic XLogic Delta Solid State Logic XLogic Delta-Link MADI HD item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Solid State Logic XLogic Delta Solid State Logic XLogic Delta-Link MADI HD alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Solid State Logic XLogic Delta Solid State Logic XLogic Delta-Link MADI HD, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Solid State Logic service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Solid State Logic XLogic Delta Solid State Logic XLogic Delta-Link MADI HD.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Solid State Logic XLogic Delta Solid State Logic XLogic Delta-Link MADI HD item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
X X L L o o g g i i c c D D e e l l t t a a - - L L i i n n k k M M A A D D I I H H D D MADI Interface for Digidesign ® HD Systems Installation and User Guide 82S6ALS20C Solid State Logic S O U N D || V I S I O N[...]
-
Page 2
[...]
-
Page 3
Safety and Installation Considerations 1 1. Introduction 3 XLogic Delta-Link MADI HD 3 Reading conventions 4 2. Overview 5 Front panel 5 Rear panel 6 3. Installation 8 4. Synchronization 10 Pro T ools ® HD card 10 Delta-Link MADI HD 10 W ordClock / FrameClock 1 1 High Speed and SMUX modes 12 5. Sample Rates and I/O Mapping 12 I/O mapping and Sampl[...]
-
Page 4
[...]
-
Page 5
This section contains definitions, warnings, and practical information to ensure a safe working environment. Please take time to read this section befor e installing or using this unit. Please do not dispose of these instructions. Safety and Installation Considerations General Safety • Read these instructions. • Keep these instructions. • Hee[...]
-
Page 6
2[...]
-
Page 7
3 XLogic Delta-Link MADI HD Congratulations on your purchase of the XLogic Delta-Link MADI HD! Please be assured that it will provide you with many years of reliable service while delivering the pristine audio quality you expect from any Solid State Logic product. The Delta-Link MADI HD is an elegantly styled, 1U high, rack mountable unit. The fron[...]
-
Page 8
Reading conventions Software menus Where appropriate, to indicate a “path” under a Solid State Logic or Pro T ools ® software menu, the following format will be used; menu: Header|Submenu 1|Submenu 2|Submenu 3|Item. Screenshots The appearance of SSL or Pro T ools ® software on your computer screen may be different from the screenshots in this[...]
-
Page 9
5 Front panel Power switch Lock LED Power LED Power switch This switch is used to power the unit up or down. Power LED This LED is lit when the Delta-Link MADI HD is switched on. Lock LED This LED indicates that a W ordClock signal is received: • It is lit when the Delta-Link MADI HD is receiving a stable signal at the required sample rate. • I[...]
-
Page 10
Rear panel Primary Port A Primary Port B USB Port Mains connector MADI Port A output (left) MADI Port B output (left) W or dClock input and input (right) and input (right) 6[...]
-
Page 11
7 Primary Port A / Primary Port B Each Pro T ools ® HD port provides 32 input and output channels, regardless of sample rate. MADI A / MADI B The two MADI ports provide up to 64 input and output channels, depending on sample rate. Both MADI interfaces are fibre optic usin g SC- type connecto rs; we of fer a separa te external MADI coaxial to optic[...]
-
Page 12
The Delta-Link MADI HD package includes: • The Delta-Link MADI HD unit. • 2 of 0.9m (35") DigiLink cables. • The mains connection cable. • This manual. NOTE: The maximum allowable length of cables r equired to connect the Digidesign ® car ds to the Delta-Link MADI HD (DigiLink cables) varies as follows accor ding to the sample rate be[...]
-
Page 13
9 1. In a typical setup, connect Primary Port A of the Delta-Link MADI HD to the Primary Port of your HD Core card and Pri mar y Port B of the Delt a-L ink MA DI HD to th e Prima ry Port of y our fir st HD Accel ca rd via Digi Lin k ca ble s suppl ied . T echnically , any Primary Port of the Delta-Link MADI HD is compatible with any Primary Port of[...]
-
Page 14
Pro T ools ® HD card The Pro T ools ® HD card is designed to operate as a Clock Slave, locking to a clock reference signal provided by the audio unit connected to its primary port. The interface unit can define the sample rate internally , or can itself be synchronized to an external reference signal (e.g. W ordClock). Whenever the user selects a[...]
-
Page 15
1 1 W ordClock / FrameClock The W ordClock input can translate W ordClock or FrameClock to the required Sample Rate. The “LOCK” LED on the front panel indicates reception of a stable signal. NOTE: When a “multiplexing” mode is used for digital audio transfers, the frame rate of the audio clock is equal to the audio sample rate at up to 48kH[...]
-
Page 16
High Speed and SMUX modes • Sampli ng frequencies up to 48kHz are des ignate d as being in the “NFS rang e” (from NFs, Normal Freq uency sampling) . • Sampling frequencies above 48kHz and up to 96kHz are in the “DFS range” (from DFs, Double Frequency sampling). • Sampling frequencies above 96kHz and up to 192kHz are in the “QFS rang[...]
-
Page 17
13 I/O mapping and Sample Rate range NFS range (44.1kHz to 48kHz): 64-48 “normal” mode T wo Primary Ports interact with one MADI Port. Primary Port A, channel 01 ↔ MADI Port A, channel 0 Primary Port A, channel 32 ↔ MADI Port A, channel 32 Primary Port B, channel 33 ↔ MADI Port A, channel 33 Primary Port B, channel 64 ↔ MADI Port A, cha[...]
-
Page 18
NFS range (44.1kHz to 48kHz): 64-48 “special” mode T wo Primary Ports interact with two MADI Ports. Primary Port A, channel 01 ↔ MADI Port A, channel 01 Primary Port A, channel 32 ↔ MADI Port A, channel 32 Primary Port B, channel 33 ↔ MADI Port B, channel 33 Primary Port B, channel 64 ↔ MADI Port B, channel 64 NOTE: The 64-48 special mo[...]
-
Page 19
15 DFS range (88.2kHz to 96kHz): 64-96 mode T wo Primary Ports interact with two MADI Ports. Primary Port A, channel 01 ↔ MADI Port A, channel 01 Primary Port A, channel 32 ↔ MADI Port A, channel 32 Primary Port B, channel 33 ↔ MADI Port B, channel 33 Primary Port B, channel 64 ↔ MADI Port B, channel 64 MADI A MADI B Primary Port A Primary [...]
-
Page 20
QFS range (176.4kHz to 192kHz): 32-192 mode One Primary Port interacts with two MADI Ports. Primary Port A, channel 01 ↔ MADI Port A, channel 01 Primary Port A, channel 16 ↔ MADI Port A, channel 16 Primary Port A, channel 17 ↔ MADI Port B, channel 17 Primary Port A, channel 32 ↔ MADI Port B, channel 32 MADI A MADI B Primary Port A Primary P[...]
-
Page 21
17 General information The Delta-Link MADI HD can work with Pro T ools ® HD systems running on a W indows P C or Macintosh OS X computer . Using the Delta-Link MADI HD with the Pro T ools ® software is generally straightforward. However, there are a few points to be aware of: • The Delta-Link MADI HD appears in the Pro T ools ® software as fo [...]
-
Page 22
The screenshot below was made using a Pro T ools ® HD system with a single Del ta-Link MADI HD which appears as a set of 192 I/O peripherals (see below , top left). All the inputs and outputs listed belong to this single unit. 18[...]
-
Page 23
19 Remote control of Delta-Link MADI HD settings Some Delta-Link MADI HD system settings can be controlled via the Analog Out tab of the Pro T ools ® software’ s Hardware Setup window (select Setup|Hardw are ).[...]
-
Page 24
In the Hardware Setup window , the “Output T rim” settings are irrelevant to the Delta-Link MADI HD because its inputs and outputs are all digital. Therefore, they can be used to set various Alpha-Link parameters as follows: The 56/28/14 channel MADI mode of the Delta-Link MADI HD does not currently support varispeed operation whilst the 64/32/[...]
-
Page 25
21 Known issues Start up errors When the Pro T ools ® software starts up, it uses the settings defined during the previous session, e.g. number and type of Audio Interfaces, I/O setup, etc. If you have used a Legacy Audio Interface (defined through menu: Setu p|Hardware ), and then replaced its current Audio Interfaces with the Delta-Lin k MADI HD[...]
-
Page 26
The best way to ensure all Legacy Interfaces are removed is to click the name of a Legacy Audio Interface (e.g. 882/20 or 888/24) and to select “No Interfaces” from the “Interface” drop down box. After the Legacy Interfaces have been removed, select the 192 I/O device, click the “Main” tab and select “Expansion I/O” in the “Port S[...]
-
Page 27
23 Playback Engine The Delta-Link MADI HD provides up to 64 input and output channels. Therefore, the number of voices for the Playback Engine may need to be increased. For instance, in order to playback and record 64 tracks simultaneously at 96kHz, go to menu: Setup|Pla yback Engine and select “128 voices”.[...]
-
Page 28
System Resources The system resource usage can always be checked in the Pro T ools ® software under menu: Windo w|System Usage : Firmware Updates The Delta-link MADI HD features a USB connector on th e bac k pane l to allo w for fire wir e upda tes or setti ngs modifications. When a new fi rmwa re update is relea sed, an updat e utility wil l be a[...]
-
Page 29
25 Symptoms Possible solutions The Delta-Link MADI HD is not detected by the software. Check that the Delta-Link MADI HD is connected to the mains supply and that the Power switch is in the On position (the Power LED should be lit). Check the condition of the mains cable. Check that the Delta-Link MADI HD is connected to the Pro T ools ® HD cards [...]
-
Page 30
26 8. Specifications Physical * Depth 175mm / 7" casing only Height 44.5mm / 1.75" (1 RU) W idth 438mm / 17.25" casing only 482mm / 19" inc’ rack ears W eight 2.2kg / 5 pounds Power < 15 W atts Boxed size 320mm x 550mm x 80mm 12.75" x 21.75" x 3.25" Boxed weight 2.7kg / 6 pounds * All values are approximate E[...]
-
Page 31
27 This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmfu l interfe rence in a res identia l instal lation. This equi pment gener ates , uses a nd ca n radi ate ra dio fr equen cy en erg y and, if[...]
-
Page 32
Solid State Logic S O U N D | | V I S I O N V isit SSL at URL: http://www .solidstatelogic.com © Solid State Logic All Rights reserved under International and Pan-American Copyright Conventions VHD, VHD logo, Xlogic, XLogic Delta and Xlogic Alpha are trademarks of Solid State Logic All other product names and trademarks are the property of their r[...]