Go to page of
Similar user manuals
-
DJ Equipment
Sonic Impact Technologies DVT38S2IN
4 pages 0.29 mb -
Stereo Amplifier
Sonic Impact Technologies Power 2
17 pages 0.48 mb -
DJ Equipment
Sonic Impact Technologies DVT44IN
4 pages 0.29 mb -
MP3 Player
Sonic Impact Technologies Video-55
24 pages 1.57 mb -
DJ Equipment
Sonic Impact Technologies DVT38IN
4 pages 0.29 mb -
CD Player
Sonic Impact Technologies SFT-1
8 pages 0.29 mb -
Network Card
Sonic Impact Technologies USB Mat
14 pages 0.48 mb -
Frozen Dessert Maker
Sonic Impact Technologies NSA 2400MX
46 pages 6.47 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Sonic Impact Technologies NSA 2400MX, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Sonic Impact Technologies NSA 2400MX one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Sonic Impact Technologies NSA 2400MX. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Sonic Impact Technologies NSA 2400MX should contain:
- informations concerning technical data of Sonic Impact Technologies NSA 2400MX
- name of the manufacturer and a year of construction of the Sonic Impact Technologies NSA 2400MX item
- rules of operation, control and maintenance of the Sonic Impact Technologies NSA 2400MX item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Sonic Impact Technologies NSA 2400MX alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Sonic Impact Technologies NSA 2400MX, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Sonic Impact Technologies service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Sonic Impact Technologies NSA 2400MX.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Sonic Impact Technologies NSA 2400MX item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
1 SonicOS 5.7: Advanced Switching Fe ature Guide and Screencas t Tutorial SonicOS 5.7: Advanced Switching Feature Guide and Screencast Tutorial This solutions document des cribes ho w to configure and m anage the Switching fea ture on a SonicW ALL NSA 2400MX r unning SonicOS 5.7. A screencast tu torial on P ort Mirroring is also provided. This docu[...]
-
Page 2
Feature Overview 2 SonicOS 5.7: Advanced Switching Fe ature Guide and Screencast Tutoria l Feature Overview This section provides an introduction to the Swit ching feature . This section contains the following subsections: • “What is Switching on the SonicW ALL NSA 2400MX?” section on page 2 • “Benefits of Switching in SonicOS” section [...]
-
Page 3
Feature Overview 3 SonicOS 5.7: Advanced Switching Fe ature Guide and Screencas t Tutorial Benefits of Switching in SonicOS The SonicW ALL NSA 2400MX pro vides a combined securi ty and switc hing solutio n with the objective of improv ed security for all tasks. Layer 2 switc hing feat ures enhance the de ployment and interoperability of SonicW all [...]
-
Page 4
Feature Overview 4 SonicOS 5.7: Advanced Switching Fe ature Guide and Screencast Tutoria l How Does Switching Work on the SonicWALL NSA 2400MX? The switching features hav e their o wn men u g roup in the left navigation pane of the SonicOS manag ement interface. Figure 1 Switching in SonicOS – Navigation Pane Some switching features operate on P [...]
-
Page 5
Configuring Switching 5 SonicOS 5.7: Advanced Switching Fe ature Guide and Screencas t Tutorial Configuring Switching This section contains the following sections: • “Configuring VLAN T r unk ing” section on pag e 5 • “Configuring Rapid Spanning T ree” section on pag e 13 • “Configuring Layer 2 Discov er y” section on page 1 8 •[...]
-
Page 6
Configuring Switching 6 SonicOS 5.7: Advanced Switching Fe ature Guide and Screencast Tutoria l Figure 2 shows the Switching > VLAN T runking pag e. The page displays the rang e of reser ved VLANs in the R e s e rv e d V L AN I n fo rm at i o n se ction, details about cur rent VLANs in the VLAN T able , and the VLAN tr unks configured on the sys[...]
-
Page 7
Configuring Switching 7 SonicOS 5.7: Advanced Switching Fe ature Guide and Screencas t Tutorial The values displa yed on the Switch ing > V LAN T r unking pag e are described in Ta b l e 1 . T able 1 VLAN Tr un ki ng Page Description Item Descriptio n Reserved VLAN Information Starting VLAN ID The lowest ID number in the VLAN range reser ved for[...]
-
Page 8
Configuring Switching 8 SonicOS 5.7: Advanced Switching Fe ature Guide and Screencast Tutoria l Y ou can mark certain P or tShield g roups as “T r unked”. F or infor m ation about how to do this , see the “Editing VLANs” section on page 12 . Once the P or tShield g roup is dismantled, the associated VLAN is automatically disabled on the tr [...]
-
Page 9
Configuring Switching 9 SonicOS 5.7: Advanced Switching Fe ature Guide and Screencas t Tutorial Y ou can c hang e the VLAN ID of PortShield grou ps on the SonicW ALL NSA 2400MX appliance . This allows easy integration with existing VLAN n umbering . Unlike traditional La yer 2 sw itches, th e SonicW ALL NSA 2400MX applian ce does not allow changing[...]
-
Page 10
Configuring Switching 10 SonicOS 5.7: Advanced Switching Fe ature Guide and Screencast Tutoria l Figure 5 shows the user interface while enabling th e local VLAN 3787 on the trun k por t, X20. Figure 5 Enabling a Lo cal VLAN on a VLAN T runk In Figu re 6 , the VL AN T a b le on th e Switching > VLAN T r unkin g pag e displays the tr unk por t, X[...]
-
Page 11
Configuring Switching 11 SonicOS 5.7: Advanced Switching Fe ature Guide and Screencas t Tutorial Figure 7 illustrates a VLAN tr unk with two trunk por ts, bridging the Sales , Engin eering, QA, and Finance VLANs through the SonicW ALL NSA 24 00MX. Each remote VLAN is initially enabled on VLAN tr unk port X20 , causing the creation of four virtual V[...]
-
Page 12
Configuring Switching 12 SonicOS 5.7: Advanced Switching Fe ature Guide and Screencast Tutoria l Editing VLANs T o edit a VLAN, perform the following steps: Ste p 1 On the Switching > VLAN T runking page, click the Configur e icon in the VLAN T able row for the VLAN ID you w ant to edit. Ste p 2 In the Edit Vlan for Por tShield window , do one o[...]
-
Page 13
Configuring Switching 13 SonicOS 5.7: Advanced Switching Fe ature Guide and Screencas t Tutorial Enabling a VLAN on a Specific Trunk Port Using this method rather than the method described in “Editing VLANs” on page 12 , you can specify a single tr unk por t to be used for a particular VLAN ID . T o enable a custom VLAN ID on a specific tr unk [...]
-
Page 14
Configuring Switching 14 SonicOS 5.7: Advanced Switching Fe ature Guide and Screencast Tutoria l allows faster spanning tree con vergence after a topolog y change, typically within 3 times the He llo i nterval, a total of 6 seconds in the default configuration. Th e or iginal STP can take 30 to 50 seconds for con vergence after a topolog y change. [...]
-
Page 15
Configuring Switching 15 SonicOS 5.7: Advanced Switching Fe ature Guide and Screencas t Tutorial The settings displayed in the Bridg e Infor mation secti on of the Switching > Rapid Spanning T ree page are described in Ta b l e 2 . T able 2 RSTP Co nfigu rable Objects Auto detection of non-edge por ts is not suppor ted. A no n-edge port is one t[...]
-
Page 16
Configuring Switching 16 SonicOS 5.7: Advanced Switching Fe ature Guide and Screencast Tutoria l Figure 9 illustrates the possibl e loop that is logi cally blocked when por ts in the same VLAN exi st on multiple connected switches in a netw ork. Figure 9 RSTP on VLAN Trunk Ports Detect s and Blocks Loops Between Switches Y ou can view the port sett[...]
-
Page 17
Configuring Switching 17 SonicOS 5.7: Advanced Switching Fe ature Guide and Screencas t Tutorial Configuring Bridge Settings T o configure the Bridg e Settings on the Switching > Rapid Spanning T ree page, perfor m the following steps: Ste p 1 T o s pecify the spanning tree protocol version to use, select one of the follo w ing from the Fo r c e[...]
-
Page 18
Configuring Switching 18 SonicOS 5.7: Advanced Switching Fe ature Guide and Screencast Tutoria l Ste p 2 In the Edit RSTP Settings window , select the Enable RSTP checkbo x to enable Rapid Sp anning T ree Protocol for this interface. Clear the c h eckbox to disable RSTP on this interface . Ste p 3 T o allow the path cost for the por t to be auto ma[...]
-
Page 19
Configuring Switching 19 SonicOS 5.7: Advanced Switching Fe ature Guide and Screencas t Tutorial On many switches and netw o rk devices, the LLDP information is stored as a manag ement infor mation database (MIB). Simple Netw ork Manag ement Protoc ol (SNMP) is used to query the MIB for device infor m ation, including syste m name, port nam e, VLAN[...]
-
Page 20
Configuring Switching 20 SonicOS 5.7: Advanced Switching Fe ature Guide and Screencast Tutoria l Viewing Device Information in the Layer 2 Discovery Page T o view the LLDP/LL TD discov er y results for your network, perform the following steps: Ste p 1 Enable LLDP on any switches or other network devices in your netw ork, using a command such as ?[...]
-
Page 21
Configuring Switching 21 SonicOS 5.7: Advanced Switching Fe ature Guide and Screencas t Tutorial Configuring Link Aggregation SonicOS 5.7 suppor ts the IEEE 802.1AX-2008 Link Ag g reg ation Control Protocol (LA CP). LA CP is used when multiple netw ork ports are conn ected in parallel between tw o sw itches or between a switch and a ser ver . Link [...]
-
Page 22
Configuring Switching 22 SonicOS 5.7: Advanced Switching Fe ature Guide and Screencast Tutoria l Figure 14 illustrates the two types of link ag gre gatio n. Figure 14 T wo Types of Link Aggregation: NSA to Serv er an d NSA to Switch Similarly to PortShield config uration, you select an in terface that represents the ag greg ated g roup . This por t[...]
-
Page 23
Configuring Switching 23 SonicOS 5.7: Advanced Switching Fe ature Guide and Screencas t Tutorial Creating a Logical Link T o create a Logical Link, perfor m the following steps: Ste p 1 On the Switching > Link Agg reg ation pag e, click the Add b utton. Ste p 2 In the Add LAG Port window , select the interface from the Por t drop-down list. Ste [...]
-
Page 24
Configuring Switching 24 SonicOS 5.7: Advanced Switching Fe ature Guide and Screencast Tutoria l Ste p 8 In the Add LAG Port window , select the interface for the link partner from the Por t drop-down list. Ste p 9 If you specified a k ey for the first interface (the ag g regator), clear the Auto-Detect check b ox a n d ty p e th e same key into th[...]
-
Page 25
Configuring Switching 25 SonicOS 5.7: Advanced Switching Fe ature Guide and Screencas t Tutorial Configuring Port Mirroring Y ou can configure P ort Mir roring on the SonicW ALL NS A 2400MX to send a copy of network pac kets seen on one or more switch ports (or on a VLAN) to another switch port called the mir ror por t. By connecting to the mirr or[...]
-
Page 26
Configuring Switching 26 SonicOS 5.7: Advanced Switching Fe ature Guide and Screencast Tutoria l Ste p 2 In the Edit Mir ror Gr oup window , type a descriptive name for the g roup into the Interface Group Name field. Ste p 3 Fo r t h e Dir ection , select one of the following: • ingr ess – Select ing ress to monitor traffic ar riving on the mir[...]
-
Page 27
Configuring Switching 27 SonicOS 5.7: Advanced Switching Fe ature Guide and Screencas t Tutorial Configuring Layer 2 Quality of Service Quality of ser vice (QoS) refers to a method of resource control that prov ides differen t prio rity to different types of applications, data, or users . QoS can also be used to guarantee a cer tain bit rate, dela [...]
-
Page 28
Configuring Switching 28 SonicOS 5.7: Advanced Switching Fe ature Guide and Screencast Tutoria l In SonicOS , four queues with different priority levels (low , nor mal, high, highest) are suppor ted. These are mapped to the eight levels defined in IEEE 802.1p (CoS) and cannot be changed. Ta b l e 4 shows the mapping between the CoS priority lev els[...]
-
Page 29
Configuring Switching 29 SonicOS 5.7: Advanced Switching Fe ature Guide and Screencas t Tutorial • Strict Priorit y Queue – When Strict Priority Queue is selected, pack ets containing an 802.1p tag or DSCP marking with a priority lev el matching the Highest queue priority are forward ed or received. P ackets matching High, Nor mal or Low priori[...]
-
Page 30
Configuring Switching 30 SonicOS 5.7: Advanced Switching Fe ature Guide and Screencast Tutoria l Configuring QoS Settings The QoS Settings table on the Switching > Layer 2 Q o S pag e lists all interfaces on the SonicW ALL NSA 2400MX. Y ou can configure the QoS settings for eac h interf ace individually or for m u ltiple i nterfaces at the same [...]
-
Page 31
Configuring Switching 31 SonicOS 5.7: Advanced Switching Fe ature Guide and Screencas t Tutorial Ste p 5 If both Tr u s t C o S and Tr u s t D S C P are selected, do one of the following: • Select the Prefer CoS checkbo x to give preference to the Co S 802.1p tag field settings when both the 802.1p tag field and the DSCP field are present in ingr[...]
-
Page 32
Configuring Switching 32 SonicOS 5.7: Advanced Switching Fe ature Guide and Screencast Tutoria l Ste p 5 T o enable the use of the DSCP field settings for Quality of Service on these interfaces , select the Tr u s t DSCP check box. T h e Fixed Priority c heckbox must be cleare d before you can select this checkbo x. Ste p 6 If both Tr u s t C o S a[...]
-
Page 33
Configuring Switching 33 SonicOS 5.7: Advanced Switching Fe ature Guide and Screencas t Tutorial The Switching > Rate Control pag e, shown in Figure 19 , provides information and configuration for per-inter f ace rate limiting and flow control. Both the rate limiting and flow control features are configured on a per port basis . Figure 19 Switch[...]
-
Page 34
Configuring Switching 34 SonicOS 5.7: Advanced Switching Fe ature Guide and Screencast Tutoria l Flow Control In SonicOS, b ack-pressure flow control on half-d uplex por ts and pause frame-based flow c ontrol on full-duplex ports are p rovided to support zero pack et loss under temporar y traffic cong estion. • Full-dupl ex flow cont rol requires[...]
-
Page 35
Configuring Switching 35 SonicOS 5.7: Advanced Switching Fe ature Guide and Screencas t Tutorial Ste p 4 T yp e the desired ingress rate limi t in kilobits per seco nd into the In gress R ate field. T o turn off the ing ress rate limit and allow un limited traffic , type 0 (zero). The value you type will be rounded to the nearest increment, dependi[...]
-
Page 36
Configuring Switching 36 SonicOS 5.7: Advanced Switching Fe ature Guide and Screencast Tutoria l See the following procedures for infor mation about configurin g por t security: • “Creating a Secure P or t by Adding a MA C Address Object” on pag e 36 • “Editing MA C Address Objects in Port Security Settings” on page 37 • “Deleting M[...]
-
Page 37
Configuring Switching 37 SonicOS 5.7: Advanced Switching Fe ature Guide and Screencas t Tutorial Ste p 6 Select the zone from the Zone Assignment drop-down list. This is the zone for the computer with this MA C address. Y ou can select any zone that exists on the SonicW ALL NSA 2400MX, including custom zones and the SonicOS default zones , which ar[...]
-
Page 38
Troublesh ooting and Verificat ion 38 SonicOS 5.7: Advanced Switching Fe ature Guide and Screencast Tutoria l Troubleshooting and Verification This section provides methods you can use to verify and troubleshoot the beha v ior of your Switching configuration. See the following sections: • “Using P or t Mir roring with Wiresh ark” on pag e 38 [...]
-
Page 39
Troubleshooting and Verification 39 SonicOS 5.7: Advanced Switching Fe ature Guide and Screencas t Tutorial Ste p 2 In the Edit Mir ror Group window , type a name for the Mir ror Group . Ste p 3 Fo r Dir ection , select both . T his allows mir roring of traffic ar riving on, and being transmitted from, the mirrored por ts . Ste p 4 In the All Inter[...]
-
Page 40
Troublesh ooting and Verificat ion 40 SonicOS 5.7: Advanced Switching Fe ature Guide and Screencast Tutoria l The X20, X24, and X25 interfaces are shown below on the Netw ork > Interfaces pag e . Y ou can see that all three are gigabit Ether net por ts , that the Zone for X 20 is Unassigned and it is configured as a Mir ror P or t, and that X24 [...]
-
Page 41
Troubleshooting and Verification 41 SonicOS 5.7: Advanced Switching Fe ature Guide and Screencas t Tutorial Ste p 6 Launch Wiresh ark . Ste p 7 Do one of the following: – Click the Start Captur e button in the upper left corner , and then, in the dialog box, select the Start chec kbox for the gigabit interface connected to the Mir ror P o rt. –[...]
-
Page 42
Troublesh ooting and Verificat ion 42 SonicOS 5.7: Advanced Switching Fe ature Guide and Screencast Tutoria l Viewing Log Event Messages for Switching A new log event, lo gstrAdvSwitch , is introduced in SonicOS 5.7 to address SonicOS Switching acti vities . It falls under a new categor y , Adv anced Switching, which can only be seen on devices wit[...]
-
Page 43
Troubleshooting and Verification 43 SonicOS 5.7: Advanced Switching Fe ature Guide and Screencas t Tutorial Filtering the Log for Switching Events T o display only the log events related to switching, perfor m the following steps: Ste p 1 Navigate to the Log > View page in the SonicOS management interface. Ste p 2 In the Log View Settings sectio[...]
-
Page 44
Technical FAQ 44 SonicOS 5.7: Advanced Switching Fe ature Guide and Screencast Tutoria l Technical FAQ How do I view the CAM table on the SonicWALL NSA 2400MX? The SonicOS 5.7.0.0 user interface or CLI does not provide a w ay to display the CAM, or MA C Address , table directly , but provides the same infor mation in the ARP table and on the Switch[...]
-
Page 45
Glossary 45 SonicOS 5.7: Advanced Switching Fe ature Guide and Screencas t Tutorial Glossary BPDU Bridge Protocol Data Unit – Used in RSTP , BPDUs are special data frames used to exc hang e infor m ation about bridge IDs and root path costs. BPDUs are ex chang ed every few seconds to all o w swi tc hes to k eep track of netw ork topolog y and sta[...]
-
Page 46
Glossary 46 SonicOS 5.7: Advanced Switching Fe ature Guide and Screencast Tutoria l Solution Document Version History V ersion Number Date Notes 1 3/30/2010 This document was created by Susan W eig and 2 5/19/2010 Added conceptual information, more details about configuration, T roubleshootin g and T echnical F A Q sections . Embedded P or t Mir r [...]