A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Spectra GL612, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Spectra GL612 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Spectra GL612. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Spectra GL612 should contain:
- informations concerning technical data of Spectra GL612
- name of the manufacturer and a year of construction of the Spectra GL612 item
- rules of operation, control and maintenance of the Spectra GL612 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Spectra GL612 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Spectra GL612, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Spectra service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Spectra GL612.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Spectra GL612 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
GL400 Series www .trimble.com T rimble Construction Division 5475 Kellenburger Road Dayton, Ohio 45424 USA +1-937-245-5600 Phone www .trimble.com User Guide Bedienungsanleitung Manuel de l´utilisateur Guida per l´uso Gúia del usuario Gebruikershandleiding Operatörshandbok Brugermanual Guia do Usuário Bruksanvisning Käyttäjän opas 取扱説?[...]
-
Page 2
Printed in Germany Q104848 Rev . D(05/13) Ser vice and Customer Advice North & Latin America T rimble Spectra Precision Division 8261 State Route 235 Dayton, Ohio 45424 U.S.A. +1 (888) 272-2433 (T oll Free in U.S.A.) +1-937-482-0030 Fax www .trimble.com www .spectraprecision.com www .spectra-productivity .com Africa & Middle East T rimble E[...]
-
Page 3
1 T ABLE OF CONTENTS Introduction 2 FOR YOUR SAFETY 2 COMPONENTS 2 How to use the Laser System 3 Powering the Laser 3 RC602 Radio Remote Control 3 T urning On/Off the RC602 3 LASER SETUP 4 T urning On/Off the Laser 4 Features and functions 4 Standard Features 5 X-Y -grade entering mode 5 Using the Rotation mode 6 Manual mode 6 Special MENU Features[...]
-
Page 4
2 Introduction Thank you for choosing one of the Spectra Precision Lasers from the T rimble family of precision lasers. The grade laser is an easy-to-use tool that offers accurate horizontal, vertical and sloped laser reference up to 1300 ft (400 m) away using a receiver . For Y our Safety For hazardless and safe operation, read all the user guide [...]
-
Page 5
3 HOW TO USE THE LASER SYSTEM POWERING THE LASER Batteries W ARNING Ni-MHbatteries maycontain smallamounts ofharmful substances. Besure tocharge thebattery before using it for the first time, and after not using it for an extended length of time. Char[...]
-
Page 6
4 LASER SETUP Position the laser horizontally (tripod mount and rubber feet downward!) on a stable platform, wall mount or tripod at the desired elevation. The laser recognizes automatically whether it is used horizontally or vertically when switched on. T urning On/Off the laser PressthepowerbuttontoturnOn/Offthelaser . [...]
-
Page 7
5 Standard Features X-Y -grade entering – Step and Go mode Quicklypressandreleasebutton 2 startsthegradeenteringmode.Bothgradevalueswillbeshown. Press/releasebutton 1 a grade reverse Y Press/releasebutton 2 a gradereverseX(onlyGL622) Press/releasebutton 3 a return[...]
-
Page 8
6 Usebutton 1 or 2 (PlusorMinus)tosetthedesireddigit. Thelaserwillself-leveltotherequiredgradepositionafterconfirmingthegradechangewithbutton 4 . Note: Thebubble symbolsatthe laser ’sLCDwillflash untilthe laserhasbeen self-leveled?[...]
-
Page 9
7 Menu functions when set up horizontal Menu functions when set up vertical Note: Pairing function is needed to pair an already paired remote with a new transmitter . The new transmitter has to be set to the pairing dialog for this operation. Otherwise the pairing can not be successful processed. The pairing information of the previous pairing is s[...]
-
Page 10
8 Automatic PlaneLok mode The PlaneLok mode can be activated in horizontal and vertical automatic and manual mode. In PlaneLokmode when set up horizontal, the beam will be locked toafixedelevationpoint(up to80m(260ft)located ononeaxis at each side of the laser . For[...]
-
Page 11
9 Automatic Grade Match The Grade Match mode can be activated in horizontal automatic and manual mode. In Grade Match mode, the laser can be used to measure the existing grade value between two known elevation points (up to 80 m (260 ft) [...]
-
Page 12
10 Automatic Axis Alignment (only GL622) Automatic Axis Alignment mode adjusts automatically the direction the grade axis is pointing to the receiver ’s location by an electronically simulation of rotating the unit on its base to match the hub. Using?[...]
-
Page 13
11 Info PressandreleasetheMENUbuttonattheStandardDisplayandselectInfo. Buttons 6/7 canbeusedtotogglebetweenGL,RCandRuntime. Press and release button 4 to confirm the selection. TheGL/RCinformation(softwareversion,ID,etc.)ortheruntimeoftheGL ?[...]
-
Page 14
12 Special Features - V ertical Setup Line Scan Line Scan centers the rotor horizontally and can be used to align the plumb beam to a desired horizontalposition.Press andreleasetheMENUbutton attheStandardDisplayand selectLine Scan. Pressing and releasing button 4 activates the Line Scan mode while the ro[...]
-
Page 15
13 Pairing the transmitter with remote control The chain symbol at button 1 indicates the remote has never been paired before which means no radio connectivity is given. Pressing the pairing button 1 willinitiate a pairingrequest.The transmitterhas tobe in pairing mode as shown above. Note : Make sure th[...]
-
Page 16
14 Grade Entry SelecttheGradeEntryiconandpressandreleasebutton 4 toopentheGradeEntrymenu. Buttons 6/7 canbeusedtotogglebetweenStepandGoandDigitSelect. Press and release button 4 to confirm the selection. Step and Go Digit Select Grade Display SelecttheGr[...]
-
Page 17
15 User Name Select the User name icon and press and release button 4 to open the User name menu. One row for typing names in big font (15) and one row in small font (18) for letters or numbers are available. Button 5 and 8 c[...]
-
Page 18
16 Select Language Select the Language icon and press and release button 4 to open the Language menu.Use button 5 to 8 to select the required locallanguage (EN, DE,IT , FR, ES, PT , NL, DA, NO,SV , FI, PL, TR, CZ). Press and release button 4 to store the selected Lan[...]
-
Page 19
17 T roubleshooting Any error messagecan bedeleted witha shortpress of button 4 (OK). The table shows the related description andpossiblesolutions.Thenextservicecentershouldbe contactedifadifferenterrormessageasshownat the table will be displayed. Error codes [...]
-
Page 20
18 PROTECTING THE UNIT Do not expose the unit to extreme temperatures or temperature changes (do not leave inside the car). The unit is very robust and can resist damage if dropped even from tripod height. Before continuing your work, always?[...]
-
Page 21
19 TECHNICAL DA T A GL622/GL612 Leveling accuracy 1,3 : ±0.5mm/10m,1/16“@100ft,10arcseconds Gradeaccuracy 1,3 : ±1.0mm/10m,1/8“@100ft,20arcseconds Rotation: 300,600,900rpm Operational area 1,2 : appr .400m(1300feet)radiuswith?[...]
-
Page 22
20 ELECTRO-MAGNETIC COMP A TIBILITY Compliancestatement(part15.19)Thisdevicecomplieswithpart15oftheFCCRulesandIndustryCanada licence-exemptRSSstandard(s).Operationissubjecttothefollowingtwoconditions:(1)thisdevice maynotcauseharmfulinterference,[...]