Speedotron D604 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Speedotron D604, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Speedotron D604 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Speedotron D604. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Speedotron D604 should contain:
- informations concerning technical data of Speedotron D604
- name of the manufacturer and a year of construction of the Speedotron D604 item
- rules of operation, control and maintenance of the Speedotron D604 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Speedotron D604 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Speedotron D604, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Speedotron service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Speedotron D604.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Speedotron D604 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    INS TRUCT ION MANUAL FOR SPEEDO TRON BROWN LINE EQUIPMENT [...]

  • Page 2

    2 3 T ABLE OF C ONTENT S Power Supplies General Information – Read This First . . . . . . . . . . . . . . . . . . . 4 Models D604, D1204, D1604 Description of Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Operating Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Power Distribution Tables . . . . .[...]

  • Page 3

    4 5 Speedotron power supplies are equipped with arc-protected outlets. However, as with any electrical equipment, arc-over (an electrical discharge between two physically dis- connected electrical terminals) is a possibility. When light cables, flash tubes or power cords are improperly seated, arc-over may occur. Also, if your light unit or power s[...]

  • Page 4

    6 7 OPERA TING INS TRUC TIONS Operation of the D604, D1204 and D1604 power supplies is simple and straight for- ward. This sequence of operation is suggested for maximum life and dependability. Make sure that the Model and Power switches are in the off position and the Push to Reset button is fully depressed into its socket. Connect light head cabl[...]

  • Page 5

    8 9 One light: Symmetrical mode in any outlet, will receive 600Ws. Asymmetrical mode in outlets 1 or 2, will receive 600Ws; when using outlets 3 or 4 output is 450Ws. Two lights: Symmetrical mode, all outlets share an equal amount of power. Two lights each receive 300Ws (600Ws divided by 2). Asymmetrical mode Combination 1: one light in outlet 1 or[...]

  • Page 6

    10 11 One light: Symmetrical mode in any outlet will, receive 1600Ws. Asymmetrical mode in outlets 1 or 2, will receive 1600Ws; when using outlets 3 or 4 output is 1200Ws. Two lights: Symmetrical mode, all outlets share an equal amount of power. Two lights each receive 800Ws (1600Ws divided by 2). Asymmetrical mode Combination 1: one light in outle[...]

  • Page 7

    12 13 D1204 Power Supply Maximum power: . . . . . . . . . . . . . . . . . . . . .1200Ws Number of light unit outlets: . . . . . . . . . . . .4 Recycle time: watt-seconds seconds (to 85% voltage, ANSI standard) 1200 4.1 600 2.0 300 1.0 Flash duration : . . . . . . . . . . . . . . . . . . . . . . .1/370 sec. (2.7 milliseconds) (at full power w/one M1[...]

  • Page 8

    14 15 *New MW9H flashtubes supplied with M11 light units handle up to 1200Ws. The MW9M flashtubes have a maximum capacity of 1000Ws. OPERA TING INS TRUC TIONS Operation of Brown Line power supplies is simple and straight forward. It is suggest- ed that this sequence of operation be utilized for maximum life and dependability. Make sure that the Mod[...]

  • Page 9

    16 17 One light: Symmetrical mode in any outlet, will receive 800Ws. Asymmetrical mode in outlets 1 or 2, will receive 800Ws; when using outlets 3 or 4 output is 600Ws. Two lights: Symmetrical mode, all outlets share an equal amount of power. Two lights each receive 400Ws (800Ws divided by 2). Asymmetrical mode Combination 1: one light in outlet 1 [...]

  • Page 10

    18 19 DESCRIPTION OF C ONTROL S Power – turns power supply on and off. (Flashes light units when turning off.) Model – turns model lamps on and off. Symmetrical/Asymmetrical – controls power distribution. In the symmetrical position, power is split equally between all lights. In the asymmetrical position power is distributed unequally and the[...]

  • Page 11

    20 21 200 100 50 150 TE CHNICAL SPE CIFICA TIONS D202 Power Supply Maximum power: . . . . . . . . . . . . . . . . . . . . .200Ws Number of light unit outlets: . . . . . . . . . . . .2 Recycle time: watt-seconds seconds (to 85% voltage, ANSI standard) 200 3.25 Flash duration . . . . . . . . . . . . . . . . . . . . . . . .1/1200 sec. (.85 millisecond[...]

  • Page 12

    22 23 To connect light units, align the light unit plug with the power supply outlet and apply even pressure while pushing. Black colored light unit connectors are of the “ quick release ” type that only require pushing the connector firmly until it is fully seated. Silvery colored light unit connectors must be threaded until they are fully sea[...]

  • Page 13

    24 25 T echnical Specifications Maximum power: MW3 (for MW3R, MW3U, M90) . . . . . . . . . . . . . .400Ws MW3C (for MW3R/CC, MW3U/CC, M90/CC) . . .400Ws MW3Q (for MW3UQ, M90Q) . . . . . . . . . . . . . . . .1200Ws MW3QC (for MW3UQ/CC, M90Q/CC) . . . . . . . .1200Ws Flash duration (MW3 and MW3C): at 400Ws . . . . . . . . . . . . . . . . . . . . . . [...]

  • Page 14

    26 27 UNIVERSAL LIGHT UNIT S (REMO V ABLE REFLE CT ORS) M11, M11/CC, M11Q and M11Q/CC The M11 series universal light units share a common base, but are differentiated by the type of flash tube each contains. They are supplied with a removable 11-1/2" reflector when purchased individually or include a 7" umbrella reflector when purchased i[...]

  • Page 15

    28 29 TROUBLE-SHOO TING System will not work at all; no flash. Check that sync cable, AC power cord and light unit cables are firmly and properly attached. Check that the flash tube is firmly seated. Check that Power switch is on. With metal camera bodies, you may be required to polarize the camera sync cable and the power supply sync extension in [...]

  • Page 16

    30 31 Ws per flash tube MW3-1 MW3Q MW9H MW9Q 100Ws 1/1500 1/1500 1/3000 1/3000 200Ws 1/1200 1/1200 1/2200 1/2200 400Ws 1/750 1/750 1/1400 1/1400 600Ws - 1/580 1/1000 1/1000 800Ws - 1/450 1/700 1/700 1200Ws - 1/330 1/500 1/500 1600Ws - - - 1/400 FLASH DURA TION Flash duration of a Speedotron Brown Line system will vary with the type of flash tube, t[...]

  • Page 17

    © 1997 Speedotron Corporation SPEEDO TRON’S LIMITED W A RRANTY Speedotron guarantees to repair or replace, free of charge, any part or parts (except for flash tubes and modeling lamps) found by factory inspection to be defective due to faulty material or workman- ship, provided the equipment is returned to our factory prepaid. The period of warr[...]