A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of SPX Cooling Technologies F400, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of SPX Cooling Technologies F400 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of SPX Cooling Technologies F400. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of SPX Cooling Technologies F400 should contain:
- informations concerning technical data of SPX Cooling Technologies F400
- name of the manufacturer and a year of construction of the SPX Cooling Technologies F400 item
- rules of operation, control and maintenance of the SPX Cooling Technologies F400 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of SPX Cooling Technologies F400 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of SPX Cooling Technologies F400, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the SPX Cooling Technologies service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of SPX Cooling Technologies F400.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the SPX Cooling Technologies F400 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    / Mar le y Class F40 0 Cooling T ower / User Manual 93-1288A[...]

  • Page 2

    2 Contents These instructions assist in obtaining efficient, long life from Marley counterflow cooling towers. Direct questions concerning cooling tower operation and maintenance to your Marley sales representative. Al- ways include your tower serial number when writing for information or ordering parts. Look for this number on the sidewall casin[...]

  • Page 3

    3 Before Start-up Among other sources, outbreaks of Legionnaires’ disease have re- portedly been traced to cooling towers. Maintenance procedures that prevent amplification and dissemination of Legionella and other airborne bacteria should be formulated and implemented BEFORE systems are operated and continued reqularly thereafter to avoid the r[...]

  • Page 4

    4 The oil level placard must be adjusted so that its “full” mark is at the same elevation as the “full” mark on the side of the Gear educer case. Check oil lines to be sure there are no leaks. See Geareducer User Manual for oil filling procedur e and list of recommended lubricants. 5–Rotate fan by hand to be sure of free rotation and amp[...]

  • Page 5

    5 TOWER PERFORMANCE –Keep the cooling tower clean and water dis- tribution uniform to obtain continued maximum cooling capacity . The capacity of a cooling tower to cool water to a given cold water tem- perature varies with the wet-bulb temperature and the heat load applied to the cooling tower . As the wet-bulb temperature drops, the cold water [...]

  • Page 6

    6 Caution cold weather operation will be enhanced if you read “Operating Cooling T owers in Freezing W eather” Marley T echnical Report #H-003 . Ice forming characteristics on any given cooling tower will vary , depending on velocity and direction of wind, circulating water rate, and heat load. Excessive ice formation may be controlled by regul[...]

  • Page 7

    7 least tower maintenance. See Cooling T ower Inspection Check List in this manual. Keep a continuous lubrication and maintenance r ecord for each cooling tower . HOT W A TER DISTRIBUTION SYSTEM –Keep the circulating water and distribution system (piping and nozzles) clean and free of dirt, algae, and scale. Algae and scale may clog nozzles, elim[...]

  • Page 8

    8 W ater T reatment BLOWDOWN –Blowdown, or bleed-of f, is the continuous r emoval of a portion of the water from the circulating system. Blowdown is used to prevent the dissolved solids from concentrating to the point where they will form scale. The amount of blowdown requir ed depends upon the cool- ing range (the differ ence between the hot and[...]

  • Page 9

    9 compounds which contain copper are not recommended. Chlorine and chlorine containing compounds are effective algaecides and slimicides. If used, chlorine should be added as intermittent (or shock) treatment only as fr equently as needed to control the slime and algae. Chlorine and chlorine containing compounds should be added carefully since very[...]

  • Page 10

    [...]

  • Page 11

    class F400[...]

  • Page 12

    12 Spare Parts SPX Cooling T echnologies manufactur es and maintains a stock of re- placement parts for all cooling tower mechanical equipment. Shipment of these parts ar e normally made within ten days after an order is received. If emer gency service is necessary , contact the local Marley representative for assistance. T o prevent prolonged shut[...]

  • Page 13

    13 Geareducer (shutdown for 3 months or mor e). 1. If the motors have space heaters, operate mechanical equipment one hour each month. 2. If the motors do not have space heaters, operate mechanical equipment one hour each week. 3. At startup, operate mechanical equipment one hour or until oil is warm, then shut the equipment down. Drain the oil and[...]

  • Page 14

    14 T r oubleshooting Remedy 1. Check power at starter . Correct any bad connections be- tween the control apparatus and the motor . 2. Check starter contacts and control circuit. Reset overloads, close contacts, reset tripped switches or r eplace failed con- trol switches. 3. If power is not on all leads at starter make sure overload and short circ[...]

  • Page 15

    15 Ladders, Stairways, Walkways, Handrails, Covers, Decks and Access Doors Davits, Derricks, and Hoists Inspect for General Condition Semi-annually Semi-annually Inspect and Repair for Safe Use Yearly Inspect and Repair Before Each Use As Required T r oubleshooting Remedy Cause T rouble Wr ong sequence of phases Geareducer bearings Gears L[...]

  • Page 16

    16 Inspection and Maintenance Schedule General Recommendations —more frequent inspection and mainte- nance may be desirable D–Daily W–W eekly M–Monthly Q–Quarterly S–Semiannually Y–Y early R–as Required 1. Inspect for clogging M M W W 2. Check for unusual noise or vibration D D D D 3. Inspect keys, keyways and set screws S S S S 4. [...]

  • Page 17

    17 Inspection and Maintenance Notes[...]

  • Page 18

    18 Date Inspected Inspected By Owner Location Owner’ s T ower Designation T ower Manufacturer Model No. Serial No. Process Served by T ower Operation: Continuous Intermittent Seasonal Design Conditions GPM HW °F CW °F WB °F Number of Fan Cells Structure Casing Material Structural Material Fan Deck Material Stairway? Material Ladder? Material H[...]

  • Page 19

    19 Mechanical Equipment Gear Drive Units Manufacturer Model Ratio Oil Level: Full Add Immediately Low , check again soon Oil Condition: Good Contains W ater Contains Metal Contains Sludge Oil Used—type Seals Back Lash Fan Shaft End Play Any Unusual Noises? No Y es Action Required: Drive Shafts Manufacturer Material Fans Manufacturer Fixed Pitch A[...]

  • Page 20

    7 401 WEST 129 STRE ET | O VE R LAN D P AR K, KANSAS 66213 U N ITE D ST A TES | 913 664 7 4 00 | spxcooling@spx.com | spxcooling.com In the interest of technological progress, all products are subject to design and/or material c hange without notice. ©2009 S PX Cooling T echnologies, Inc. | Printed in USA Manual 93-1288A[...]