State Industries SBD71 120 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of State Industries SBD71 120, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of State Industries SBD71 120 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of State Industries SBD71 120. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of State Industries SBD71 120 should contain:
- informations concerning technical data of State Industries SBD71 120
- name of the manufacturer and a year of construction of the State Industries SBD71 120 item
- rules of operation, control and maintenance of the State Industries SBD71 120 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of State Industries SBD71 120 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of State Industries SBD71 120, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the State Industries service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of State Industries SBD71 120.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the State Industries SBD71 120 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    MODELS COVERED SBD71 120 Through SBD85 500 T h e Ex p e r t’ s C h o ic e® COMMERCIAL T h e Ex p e r t’ s C h o ic e® COMMERCIAL Self Cleaning Commercial Gas W ater Heaters with Flue Damper and Electronic Ignition Part Number STC-072 Printed in the U.S.A. - 0106 State Water Heaters 500 T ennessee W altz Parkway Ashland City , TN 37015 800-365[...]

  • Page 2

    SBD TANK TYPE HEATERS SERVICE HANDBOOK Technical Training Department Ashland City, TN ©2003 1 SBD HANDBOOK TABLE OF CONTENTS PAGE PAGE Troubleshooting (continued) Introduction 1-2 Troubleshooting the Efflkal 28-30 W i r e H a r n e s s T e s t 3 1 Installation 3 IID Module 32 Clearances 4 Pilot Spark 33 Air Requirements 5-8 Pilot Valve 34-35 Conta[...]

  • Page 3

    SBD TANK TYPE HEATERS SERVICE HANDBOOK Technical Training Department Ashland City, TN ©2003 2 Qualifications: Installation or service of this wa ter heater requires ability equivalent to that of a licensed tradesman in the field involved. Plumbing, air supply, venting, gas supply and electrical testing skills are required. Tools Required: • Phil[...]

  • Page 4

    SBD TANK TYPE HEATERS SERVICE HANDBOOK Technical Training Department Ashland City, TN ©2003 3 INSTALLATION This portion of the handbook will review some oft en overlooked installation considerations, taking note of necessary installation requirements for the SBD 71120 through SBD 85500 model heaters. The installation manual cove rs most of these i[...]

  • Page 5

    SBD TANK TYPE HEATERS SERVICE HANDBOOK Technical Training Department Ashland City, TN ©2003 4 EXTERIOR CLEARANCE This illustrates the exterior roof clearances for SBD units with natural draft venting. The vent shall extend at least 3 feet above the hi ghest point where it passes through a roof of a building, and at least 2 feet higher than any por[...]

  • Page 6

    SBD TANK TYPE HEATERS SERVICE HANDBOOK Technical Training Department Ashland City, TN ©2003 5 AIR FOR COMBUSTION 10 CUBIC FEET OF AIR PER 1,000 BTU Stoichiometric or theoretical complete com bustion requires 10 cubic feet of air per 1000 BTUH input of the gas input. The National Fuel Gas Code also recommends an additional 2.5 cu.ft. of "exces[...]

  • Page 7

    SBD TANK TYPE HEATERS SERVICE HANDBOOK Technical Training Department Ashland City, TN ©2003 6 MAKE-UP AIR DIRECT COMMUNICATION A fresh supply of make-up air for combusti on can be supplied to t he heater through make- up air ducts which directly communicate wit h the out of doors. Tw o openings are required - one within 12 inches of the top of the[...]

  • Page 8

    SBD TANK TYPE HEATERS SERVICE HANDBOOK Technical Training Department Ashland City, TN ©2003 7 MAKE-UP AIR VERTICAL DUCTS Often it is more practical to install vertical make-up air ducts to the out doors. Again, two openings are required - one within 12 inches of the top of the enclosure and one within twelve inches of the bottom of the enclosu re.[...]

  • Page 9

    SBD TANK TYPE HEATERS SERVICE HANDBOOK Technical Training Department Ashland City, TN ©2003 8 INSUFFICIENT MAKE-UP AIR BACKDRAFT Insufficient make-up air is a major cause of combustion problems. One common example is in a restaurant installation where exhaust vent equipment was not considered in sizing make-up air requirements. This may result in [...]

  • Page 10

    SBD TANK TYPE HEATERS SERVICE HANDBOOK Technical Training Department Ashland City, TN ©2003 9 CONTAMINATED AIR Along with adequate make-up air, the quality of the air is important. Contaminants in combustion air can lead to premature heat er failure. Vapors from bleaches, soaps, waxes, salts, etc. are draw n into the combustion chamber with the ma[...]

  • Page 11

    SBD TANK TYPE HEATERS SERVICE HANDBOOK Technical Training Department Ashland City, TN ©2003 10 GAS PRESSURE REQUIREMENTS Natural Gas Propane Gas Maximum Supply Pressure 10.5" W.C. 13.8" W.C. Minimum Supply Pressure 5.0" W.C. 11" W.C. Manifold Pressure 4.0 " W.C. 10" W.C. The supply gas pressure is normally measured at[...]

  • Page 12

    SBD TANK TYPE HEATERS SERVICE HANDBOOK Technical Training Department Ashland City, TN ©2003 11 SBD GAS VALVE The gas valves used on all SBD water heaters are 24 volt AC combination step opening gas valves. They incorporate the pilot valve, main valve, and gas pressure regulators into one body. The inlet view of the valve features a filt er screen [...]

  • Page 13

    SBD TANK TYPE HEATERS SERVICE HANDBOOK Technical Training Department Ashland City, TN ©2003 12 VENTING Atmospheric, Single, and Multiple Heaters All SBD water heaters are classified by ANSI as category I (non-condensing, negative pressure venting) appliances. They are approved for type B vent. For larger applications, SBD water heaters can be comm[...]

  • Page 14

    SBD TANK TYPE HEATERS SERVICE HANDBOOK Technical Training Department Ashland City, TN ©2003 13 Nine Rules for Good Vents (continued) 2. The diameter of a vent pipe should NEVER be reduced, no matter what the circumstances. 3. In some cases it may be necessary to run a vent larger than the draft diverter outlet. 4. Take the maximum vertical rise po[...]

  • Page 15

    SBD TANK TYPE HEATERS SERVICE HANDBOOK Technical Training Department Ashland City, TN ©2003 14 Nine Rules for Good Vents (continued) 6. Horizontal pipe should be sloped upward at a minimum of ¼” per foot. 7. Horizontal elements should be limited to 75% of the vertical rise of the vent above the connection. 8. Flue gases must be kept hot for pro[...]

  • Page 16

    SBD TANK TYPE HEATERS SERVICE HANDBOOK Technical Training Department Ashland City, TN ©2003 15 POWER VENT KITS FOR SIDEWALL VENTING Water Heater Models Part Number SBD-120-200 193933-0 SBD-250-500 193933-1 SBD water heaters can be used with power vent kits for sidewall venting. State offers power vent kits for use on installations with a maximum o[...]

  • Page 17

    SBD TANK TYPE HEATERS SERVICE HANDBOOK Technical Training Department Ashland City, TN ©2003 16 SBD SEQUENCE OF OPERATION 1. Thermostat calls for heat 2. Flue damper opens 3. Intermittent Ignition Control 5. Main gas valve opens 7. Thermostat satisfies 4. Pilot gas opens, Pilot sparks and flame proves 6. Main burner ignites 8. Main and pilot burner[...]

  • Page 18

    SBD TANK TYPE HEATERS SERVICE HANDBOOK Technical Training Department Ashland City, TN ©2003 17 SBD ELECTRICAL SEQUENCE 100 – 109 Series[...]

  • Page 19

    SBD TANK TYPE HEATERS SERVICE HANDBOOK Technical Training Department Ashland City, TN ©2003 18 SBD ELECTRICAL SEQUENCE OF OPERATION 115/60/12A IID Module (24V) Receives Voltage Module (PV) Terminal Sends 24V to Pilot Coil Module (Spark) Sends 10,000V Spark to Pilot Spark Stops Damper Motor Energized and Damper Closed Power to Damper #2 Interru p t[...]

  • Page 20

    SBD TANK TYPE HEATERS SERVICE HANDBOOK Technical Training Department Ashland City, TN ©2003 19 TROUBLESHOOTING SBD WATER HEATERS To troubleshoot a SBD water heater check that: • 120 VAC is supplied to the heater • the tank is full of water • gas is supplied to the unit STEP 1 TEST THE TRANSFORMER STEP 1 - TO TEST THE TRANSFORMER - Using a mu[...]

  • Page 21

    SBD TANK TYPE HEATERS SERVICE HANDBOOK Technical Training Department Ashland City, TN ©2003 20 STEP 2 HIGH LIMIT, LEFT TERMINAL TEST STEP 2. HIGH LIMIT, LEFT TERMINAL TEST. Test for 24 VAC between the left high limit terminal and ground. IF THEN The meter does not read 24 VAC: • Check wiring between transformer and high limit. The meter reads 24[...]

  • Page 22

    SBD TANK TYPE HEATERS SERVICE HANDBOOK Technical Training Department Ashland City, TN ©2003 21 STEP 3 TEST HIGH LIMIT RIGHT TERMINAL STEP 3. TO TEST HIGH LIMIT RIGHT TERMINAL . Ensure that the jumper wire between the high limit and thermostat is c onnected, and the damper motor power line is connected. Test for 24 VAC between the high limit right [...]

  • Page 23

    SBD TANK TYPE HEATERS SERVICE HANDBOOK Technical Training Department Ashland City, TN ©2003 22 STEP 4 INSPECT THE DAMPER STEP 4. INSPECT THE DAMPER. Lower the thermostat setting so the unit will not be calling for heat, then inspect the damper. IF THEN If the damper is open: • Go to step 5. If the damper is closed: • Go to step 7. Note: If the[...]

  • Page 24

    SBD TANK TYPE HEATERS SERVICE HANDBOOK Technical Training Department Ashland City, TN ©2003 23 STEP 6 PC BOARD MOTOR TEST STEP 6. PC BOARD/MOTOR TEST. Check for 24 VAC between the two motor lead terminals of the PC board. Disconnect the wires for this test. IF THEN 24 VAC is not present: • Replace the Damper Drive (part # 194484) and go to step [...]

  • Page 25

    SBD TANK TYPE HEATERS SERVICE HANDBOOK Technical Training Department Ashland City, TN ©2003 24 STEP 7 THERMOSTAT TEST STEP 7. THERMOSTAT TEST. Set the thermostat to call for heat. Using your multimeter, test for 24 VAC between right terminal and ground. IF THEN The meter does not read 24 VAC and the jumper wire between the high limit and the t her[...]

  • Page 26

    SBD TANK TYPE HEATERS SERVICE HANDBOOK Technical Training Department Ashland City, TN ©2003 25 EFFIKAL DAMPER The wiring colors from the damper PC Board ar e different colors than the wires on the heater wiring harness. The male/female plugs to connect the damper board to the heater harness join in only one way. Adapter not necessary on production[...]

  • Page 27

    SBD TANK TYPE HEATERS SERVICE HANDBOOK Technical Training Department Ashland City, TN ©2003 26 HARNESS CHART Heater Harness Function Damper Harness Black 24V Hot 1-Brown Yellow 24V from Thermostat 2-Orange Red 24V from damper 3-Yellow White 24V common 4-Black NORMAL OPERATION Condition: • Heater on standby • Damper closed • High Limit closed[...]

  • Page 28

    SBD TANK TYPE HEATERS SERVICE HANDBOOK Technical Training Department Ashland City, TN ©2003 27 NORMAL OPERATION (continued) Condition: • Thermostat closed, damper in process of opening STEP 8A TEST FOR 24VAC BETWEEN BLACK AND ORANGE IF THEN 24VAC is present Continue to Step 8B. 24VAC is not present See Troubleshooting Step 9B. Condition: • The[...]

  • Page 29

    SBD TANK TYPE HEATERS SERVICE HANDBOOK Technical Training Department Ashland City, TN ©2003 28 TROUBLESHOOTING THE EFFIKAL DAMPER Condition: Thermostat closed, damper closed STEP 9A TEST BETWEEN BLACK (COMMON) AND BROWN ON THE DAMPER BOARD IF THEN 24VAC is present This is correct 24VAC is not present • See Steps 1 thru 4 Check the harness plugs [...]

  • Page 30

    SBD TANK TYPE HEATERS SERVICE HANDBOOK Technical Training Department Ashland City, TN ©2003 29 TROUBLESHOOTING THE EFFIKAL DAMPER (continued) Condition: Thermostat closed, damper open. STEP 9B A1 IS CORRECT, CHECK SERVICE SWITCH POSITION IF THEN Switch is incorrect position Replace damper board/motor assembly. Switch is not in correct position •[...]

  • Page 31

    SBD TANK TYPE HEATERS SERVICE HANDBOOK Technical Training Department Ashland City, TN ©2003 30 TROUBLESHOOTING THE EFFIKAL DAMPER (continued) Condition: Thermostat closed, damper is open fully STEP 10A TEST FOR 24VAC BETWEEN BLACK AND YELLOW IF THEN 24VAC is present This is correct – continue to Step 11 24VAC is not present • See Step 9B. • [...]

  • Page 32

    SBD TANK TYPE HEATERS SERVICE HANDBOOK Technical Training Department Ashland City, TN ©2003 31 STEP 11 WIRE HARNESS TEST STEP 11. WIRE HARNESS TEST. Test for 24 VAC between terminal 24V on the IID module, and 24V GND. IF THEN 24 VAC is not present: • Check the wiring harness. 24 VAC is present: • Go to step 12. Note: This test may be easier to[...]

  • Page 33

    SBD TANK TYPE HEATERS SERVICE HANDBOOK Technical Training Department Ashland City, TN ©2003 32 STEP 12 IID MODULE TEST STEP 12. IID MODULE TEST (Power to the Pilot Valve). Using a multimeter, test for 24 VAC between terminal PV and 24V (GND) on t he IID during the 90 second trial for ignition. IF THEN The meter does not read 24 VAC and the IID mod[...]

  • Page 34

    SBD TANK TYPE HEATERS SERVICE HANDBOOK Technical Training Department Ashland City, TN ©2003 33 STEP 13 PILOT SPARK TEST STEP 13. PILOT SPARK TEST. Visually check for spark at the pilot assembly. Note: The pilot burner mounts on the left side of the main burner. IF THEN The igniter is not sparking: Check for: • A 7/64” spark gap • Spark cable[...]

  • Page 35

    SBD TANK TYPE HEATERS SERVICE HANDBOOK Technical Training Department Ashland City, TN ©2003 34 STEP 14A PILOT VALVE - OHM TEST SBD 120 – 400 GAS VALVE STEP 14A. PILOT VALVE - OHM TEST. If pilot assembly is sparking but no pilot flame is established, disconnect the pilot valve solenoid leads. Using a multimeter, (set to read ohms) test for 20* oh[...]

  • Page 36

    SBD TANK TYPE HEATERS SERVICE HANDBOOK Technical Training Department Ashland City, TN ©2003 35 STEP 14B PILOT VALVE TEST – SBD 500 ONLY STEP 14B. PILOT VALVE TEST – SBD 500 ONLY. Testing the two coils of the Honeywell VR8404P 5004 gas valve used on the model SBD 500 only. Because of built in diodes, it is difficult to test for ohms resistance [...]

  • Page 37

    SBD TANK TYPE HEATERS SERVICE HANDBOOK Technical Training Department Ashland City, TN ©2003 36 STEP 15 MAIN BURNER TEST STEP 15. MAIN BURNER TEST. Visually check for main burner. IF THEN The main burner ignites: • Sequence is complete The main burner does not ignite • Go to step 16[...]

  • Page 38

    SBD TANK TYPE HEATERS SERVICE HANDBOOK Technical Training Department Ashland City, TN ©2003 37 STEP 16 FLAME RECTIFICATION STEP 16. FLAME RECTIFICATION Note: Flame rectification means that an alternating cu rrent (AC) signal is changed to a direct current (DC) signal. The pilot flame is the 'switch' which connects the pilot hood to the i[...]

  • Page 39

    SBD TANK TYPE HEATERS SERVICE HANDBOOK Technical Training Department Ashland City, TN ©2003 38 STEP 17 IID MODULE TEST Pilot is lit - Sparking has stopped. STEP 17. IID MODULE TEST (Power to the Main Valve). Using a multimeter, test for 24 VAC between terminal MV on the IID and 24V (GND). IF THEN 24 VAC is not present: • Replace the IID module. [...]

  • Page 40

    SBD TANK TYPE HEATERS SERVICE HANDBOOK Technical Training Department Ashland City, TN ©2003 39 STEP 18A MAIN GAS VALVE CHECK SBD 120 – 400 GAS VALVE STEP 18A. MAIN GAS VALVE CHECK. Disconnect wires from gas valve TH and TR terminals. Using a multimeter, test for 68 ohms plus or minus 5 between TH and TR on the main valve coil. IF THEN The meter [...]

  • Page 41

    SBD TANK TYPE HEATERS SERVICE HANDBOOK Technical Training Department Ashland City, TN ©2003 40 STEP 18B MAIN GAS VALVE COIL CHECK STEP 18B. MAIN GAS VALVE COIL CHECK – SBD 500 ONLY Condition: • Pilot lights • Sparking stops • No main burner ignition Test Procedure: • Power off • Disconnect red, main valve wire from module MV terminal ?[...]

  • Page 42

    SBD TANK TYPE HEATERS SERVICE HANDBOOK Technical Training Department Ashland City, TN ©2003 41 GENERAL SERVICE CHART CONDITION CAUSE SOLUTION DAMPER OPENS NO POWER TO IID MODULE . DAMPER NOT FULLY OPEN . DEFECTIVE PROTECTOR SWITCH .EFFIKAL – REPLACE DAMPER CONTROL ASSEMBLY . REPLACE DAMPER . REPLACE PC BOARD PILOT LIGHTS, SPARKS CONTINUOUSLY PIL[...]

  • Page 43

    SBD TANK TYPE HEATERS SERVICE HANDBOOK Technical Training Department Ashland City, TN ©2003 42 GENERAL QUESTIONS AND ANSWERS Q. What is unique about the Canadian – SBC-CGA – models vs. U.S. SBD models? A. The Canadian models have different dimensions to meet Canadian code requirements. Q: How much electrical power is required for a SBD water h[...]

  • Page 44

    SBD TANK TYPE HEATERS SERVICE HANDBOOK Technical Training Department Ashland City, TN ©2003 43 SBD MODELS 120 THRU 500A SERIES 110-111 GAS VALVES HONEYWELL VALVE SBD 500A EFFIKAL DAMPER DRIVE ASSEMBLY PARTIAL REPLACEMENT PARTS LIST MODELS SBD 120 THRU 500A: STANDARD AND ASME (A) SERIES 110/111 WHITE RODGERS VALVE SBC 120 – 400A[...]

  • Page 45

    SBD TANK TYPE HEATERS SERVICE HANDBOOK Technical Training Department Ashland City, TN ©2003 44 SBD MODELS 120 THRU 500A (continued) SERIES 110-111[...]

  • Page 46

    SBD TANK TYPE HEATERS SERVICE HANDBOOK Technical Training Department Ashland City, TN ©2003 45 SBD MODELS 120 THRU 500A (continued) SERIES 110-111 Series 110-111 1 ..........Flue Baffl e ................................. 193595 .............. 192199-3 ........... 193795-1 ......... 193696 .......... .... 193696 3 ..........Main Burner Orif ice Bra[...]

  • Page 47

    SBD TANK TYPE HEATERS SERVICE HANDBOOK Technical Training Department Ashland City, TN ©2003 46 SBD MODELS 120 THRU 500A (continued) SERIES 110-111 ITEM PARTS DESCRIPTION SBD81190NE S BD100199NES/A SBD100250NE/A S BD65251NE/A SBD100275NE/A 1 ..........Flue Baffl e ................................... 193795-1 ....... 193889 ................ 193595 .[...]

  • Page 48

    SBD TANK TYPE HEATERS SERVICE HANDBOOK Technical Training Department Ashland City, TN ©2003 47 SBD MODELS 120 THRU 500A (continued) SERIES 110-111 1 ........... Flue Baffle ........................................ 193595 ....................... 193696 ............................ 1 93995 ................ 193995 3 ........... Main Burner Orifice Br[...]

  • Page 49

    SBD TANK TYPE HEATERS SERVICE HANDBOOK Technical Training Department Ashland City, TN ©2003 48 SBD MODELS 120 THRU 500A (continued) SERIES 110-111 CGA CGA CGA CGA 1 ............. Flue Baffle ...................................... 193595........... 192199-3 ....... 193795-0 ......... 193696 193795-0 3 ............. Main Burner Orifice Bracket .....[...]

  • Page 50

    SBD TANK TYPE HEATERS SERVICE HANDBOOK Technical Training Department Ashland City, TN ©2003 49 SBD MODELS 120 THRU 500A (continued) SERIES 110-111 1 ............ Flue Baffle ..................................... 193889 ............ 193595 .............. 193595 .............. 193945 .. ....... 193595 3 ............ Main Bur ner Orifice Bra cket ...[...]

  • Page 51

    SBD TANK TYPE HEATERS SERVICE HANDBOOK Technical Training Department Ashland City, TN ©2003 50 SBD MODELS 120 THRU 500A (continued) SERIES 110-111 1 ............ Flue Baffl e ................................................... 193945 ........................ 193995 ................ ......... 193995 3 ............ Main Burner Orifice Bracket ......[...]

  • Page 52

    SBD TANK TYPE HEATERS SERVICE HANDBOOK Technical Training Department Ashland City, TN ©2003 51 COMPONENT PART INFORMATION NAME SPECIFICATIONS STATE PART NUMBERS DUAL CONTROLLER THERMOST AT 120-180 O RANGE, + 4 O , 5 O DIFFERENTIAL, LIQUID FILLED, ANTI- STACKING # 192828 HIGH LIMIT (ECO) OPENS - 205 O FIXED, MANUAL RESET BELOW 185 O GAS VALVE NATUR[...]

  • Page 53

    SBD TANK TYPE HEATERS SERVICE HANDBOOK Technical Training Department Ashland City, TN ©2003 52 SBD SERVICE CHECKLIST (This service checklist may be photo copied to assist with SBD service call.) This checklist is intended to aid the Servic e Agent in determini ng that the State SBD Water Heater has been properly installed and is operating correctl[...]

  • Page 54

    SBD TANK TYPE HEATERS SERVICE HANDBOOK Technical Training Department Ashland City, TN ©2003 53 V. WATER PIPING Is the system properly sized? yes no Is the system properly installed? yes no Are there any water leaks? yes no Does the installation have a recirculating system? yes no If so, is it operational? yes no VI. PROPER SEQUENCE OF OPERATION Du[...]

  • Page 55

    SBD TANK TYPE HEATERS SERVICE HANDBOOK Technical Training Department Ashland City, TN ©2003 54 COMMENTS Author: Terry Mulder[...]

  • Page 56

    MODELS COVERED SBD71 120 Through SBD85 500 T h e Ex p e r t’ s C h o ic e® COMMERCIAL T h e Ex p e r t’ s C h o ic e® COMMERCIAL Self Cleaning Commercial Gas W ater Heaters with Flue Damper and Electronic Ignition Part Number STC-072 Printed in the U.S.A. - 0106 State Water Heaters 500 T ennessee W altz Parkway Ashland City , TN 37015 800-365[...]