The rules should oblige the seller to give the purchaser an operating instrucion of Sterling SVL-B, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Sterling SVL-B one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Sterling SVL-B. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Sterling SVL-B should contain:
- informations concerning technical data of Sterling SVL-B
- name of the manufacturer and a year of construction of the Sterling SVL-B item
- rules of operation, control and maintenance of the Sterling SVL-B item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Sterling SVL-B alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Sterling SVL-B, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Sterling service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Sterling SVL-B.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Sterling SVL-B item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    SVL-A, SVL-B, SVL-C, & SVL-D Self-Contained Material Loaders - Venturi Style 1 of 49 Operation and Installation Instructions Self-Contained Material Loader (Compressed Air Venturi Type) SVL-A, SVL-B, SVL-C, & SVL-D Bulletin No.: CV6-600 Part No.: 882.00685.00 Effective: 7/2007 SVL-A SVL-C SVL-B[...]

  • Page 2

    SVL-A, SVL-B, SVL-C, & SVL-D Self-Contained Material Loaders - Venturi Style 2 of 49 The manufacturer retains all rights to change th e information in these operating instructions at any time without notice. We assume no liability for any errors or direct or indirect damage resulting in context with these operating instructions. Copying, transl[...]

  • Page 3

    SVL-A, SVL-B, SVL-C, & SVL-D Self-Contained Material Loaders - Venturi Style 3 of 49 Shipping Information Unpacking and Inspection You should inspect your equipment for possible shipping damage. Thoroughly check the equipment for any damage that might have occurred in transit, such as broken or loose wiring and components, loose hardware and mo[...]

  • Page 4

    SVL-A, SVL-B, SVL-C, & SVL-D Self-Contained Material Loaders - Venturi Style 4 of 49 Table of Contents Chapter 1: Safety Instructions ................................................... 6 1-1 How to Use This Manual ............................................................................................. 6 Safety Symbols Used in this Manual [...]

  • Page 5

    SVL-A, SVL-B, SVL-C, & SVL-D Self-Contained Material Loaders - Venturi Style 5 of 49 CHAPTER 6: TECHNICAL DATA ............................................. 10 * Optional 230 V, AC, PE, 50/60 Hz..................................................................................... 10 6-1 Dimension Sheet ...........................................[...]

  • Page 6

    SVL-A, SVL-B, SVL-C, & SVL-D Self-Contained Material Loaders - Venturi Style 6 of 49 Chapter 1: Safety Instructions 1-1 How to Use This Manual Use this manual as a guide and reference for installing, operating, and maintaining your loading system. The purpose is to assist you in applying efficient, proven techniques that enhance equipment produ[...]

  • Page 7

    SVL-A, SVL-B, SVL-C, & SVL-D Self-Contained Material Loaders - Venturi Style 7 of 49 DANGER! DANGER indicates an imminently hazardous situation that, if not avoided, will result in death or serious injury. WARNING! WARNING indicates a potentially hazardous situation or practice that, if not avoided, could result in death or serious injury. Caut[...]

  • Page 8

    SVL-A, SVL-B, SVL-C, & SVL-D Self-Contained Material Loaders - Venturi Style 8 of 49 1-3 For Your Safety How to Use This Manual • Please read this manual carefully before initial operation. Understandin g the instructions and equipment will help to avoid injuries as well as damage to equipment. If you have questions, contact the manufacturer.[...]

  • Page 9

    SVL-A, SVL-B, SVL-C, & SVL-D Self-Contained Material Loaders - Venturi Style 9 of 49 • Observe the safety instructions for the connected units. Maintenance Responsibility • Before beginning maintenance work:  Assign a supervisor.  Inform all other responsible operating personnel.  Turn off the main power supply.(If required)  Se[...]

  • Page 10

    SVL-A, SVL-B, SVL-C, & SVL-D Self-Contained Material Loaders - Venturi Style 10 of 49 Chapter 2: Inst allation 2-1 General Information Unpack all parts of the single conveyor unit and make sure that every thing is available: • One material receiver with level sensor • Correct type of mounting flange (direct mount, bin mount, or sight glass [...]

  • Page 11

    SVL-A, SVL-B, SVL-C, & SVL-D Self-Contained Material Loaders - Venturi Style 11 of 49 Figure 2.2: SVL-B Parts Shown w i th option al sight glass assembly Figure 2.3: SVL-C Parts Shown w i th option al sight glass assembly OR OR OR[...]

  • Page 12

    SVL-A, SVL-B, SVL-C, & SVL-D Self-Contained Material Loaders - Venturi Style 12 of 49 2-2 Installing the Material Receiver The self contained material loader can be installed directly on the processing machine. Make sure that all connections are tight so that the conveying performance is not impaired. The material receiver is equipped with a mo[...]

  • Page 13

    SVL-A, SVL-B, SVL-C, & SVL-D Self-Contained Material Loaders - Venturi Style 13 of 49 Sight Glass Mounting Flange[...]

  • Page 14

    SVL-A, SVL-B, SVL-C, & SVL-D Self-Contained Material Loaders - Venturi Style 14 of 49 Figure 2.5: Flange Mount Figure 2.7: Sight Glass Mount to Di g ital Dosin g Feede r Figure 2.6: Sight Glass Mount Figure 2.8: Standard Mount for SF-1 Feeder Note: Optional cover adapters may be required.[...]

  • Page 15

    SVL-A, SVL-B, SVL-C, & SVL-D Self-Contained Material Loaders - Venturi Style 15 of 49 2-3 Installing the Control Assembly Install the control assembly at a freely accessible site. Check the length of the connection cable and the length of the supplied hoses to the venturi assemblies. During installation of equipment, check the length of the air[...]

  • Page 16

    SVL-A, SVL-B, SVL-C, & SVL-D Self-Contained Material Loaders - Venturi Style 16 of 49 2-4 Connecting the Compressed Air Supply Before connecting the compressed air supply, check the following:  Check compressed air piping for correct installation and assembly.  Check the fittings, length and quality of the hose connections for agreement w[...]

  • Page 17

    SVL-A, SVL-B, SVL-C, & SVL-D Self-Contained Material Loaders - Venturi Style 17 of 49 2-5 Connecting Material Lines Typical SVL Loader installations use flex hose to connect the loader to th e venturi. Caution! The material hose should be as straight as possible. Avoid loops and S-curves in flexible hose. This can hurt conveying performance. 1.[...]

  • Page 18

    SVL-A, SVL-B, SVL-C, & SVL-D Self-Contained Material Loaders - Venturi Style 18 of 49 SVL-C (Two inlet) Installation Any SVL loader may be equipped for “ratio” or proportioning loading so that two materials (usually virgin and regrind) may be loaded simultaneously. The equipment for this function consists of a “Y” tube and coupler that [...]

  • Page 19

    SVL-A, SVL-B, SVL-C, & SVL-D Self-Contained Material Loaders - Venturi Style 19 of 49 2-6 Electrical Connection The operating voltage is 115 or 230 VAC, AC, PE, 50/60 Hz. Special voltages available by request. The connected load is approximately 2 Watts. The connection is made using a main connector. A separate protection of the socket is not n[...]

  • Page 20

    SVL-A, SVL-B, SVL-C, & SVL-D Self-Contained Material Loaders - Venturi Style 20 of 49 Chapter 3: Functional Description 3-1 Operational Summary Once the control switch(s) is turned on, the SVL loader uses a solid state sensor to determine if material is needed at the material destination (hopper, bin, sight glass, etc.) If the sensor “sees”[...]

  • Page 21

    SVL-A, SVL-B, SVL-C, & SVL-D Self-Contained Material Loaders - Venturi Style 21 of 49 3-2 Method of Functioning The self-contained venturi loader works according to the Venturi Principle. An external compressed air supply is needed to provide the source of compressed air. A venturi device (A) is integrated in the venturi assembly. The venturi c[...]

  • Page 22

    SVL-A, SVL-B, SVL-C, & SVL-D Self-Contained Material Loaders - Venturi Style 22 of 49 3-3 Control Assembly A. The unit is switched ON and OFF at the control. B. At the regulator, the operating pressure is adjusted. A filter/separator is integrated into the control. C. Regularly inspect the compressed air filter to make sure that it is clean and[...]

  • Page 23

    SVL-A, SVL-B, SVL-C, & SVL-D Self-Contained Material Loaders - Venturi Style 23 of 49 Chapter 4: Setup 4-1 Preparations  Check to see if the venturi assembly is inserted in the material to be conveyed.  Verify compressed air connections are properly installed.  Switch the compressed air supply ON at the compressed air source.  Check[...]

  • Page 24

    SVL-A, SVL-B, SVL-C, & SVL-D Self-Contained Material Loaders - Venturi Style 24 of 49 adjusted first for optimum flow, as described above. Since regrind material is typically more difficult to load than virgin material, it will take more compressed air (a higher setting on the regulator) than virgin material. Once regrind is adjusted, then the [...]

  • Page 25

    SVL-A, SVL-B, SVL-C, & SVL-D Self-Contained Material Loaders - Venturi Style 25 of 49 4-4 Basic Setting of the F illing Level in the Conveyor Hopper The filling level in the conveyor hopper is mainly determined by the level sensor. Figure 4.1: Conveyor Hopper Function and features: • Capacitive level switch for monitoring and dry bulk materia[...]

  • Page 26

    SVL-A, SVL-B, SVL-C, & SVL-D Self-Contained Material Loaders - Venturi Style 26 of 49 Programming: Overview of the modes and their basic functions: • Operating mode: Normal operating mode. In this mode all normal sensor functions are active. • Adjustment mode: Setting of the switchi ng threshold by empty and full adjustment. • Locking mod[...]

  • Page 27

    SVL-A, SVL-B, SVL-C, & SVL-D Self-Contained Material Loaders - Venturi Style 27 of 49 Full adjustment After empty adjustment the full state is to be achieved, if possible, so that the unit switches. The full adjustment can be repeated as often as you like. The stored value for the em pty state is not overwritten by the full adjustment. Afte r a[...]

  • Page 28

    SVL-A, SVL-B, SVL-C, & SVL-D Self-Contained Material Loaders - Venturi Style 28 of 49 Unlocking When the programming pushbutton is released the unit is unlo cked and all programming functions are active again. Error messages If empty or full adjustment cannot be made, the red LED fla shes quickly at about 8 Hz after the adjustment attempt (adju[...]

  • Page 29

    SVL-A, SVL-B, SVL-C, & SVL-D Self-Contained Material Loaders - Venturi Style 29 of 49 Set-up / Operation: Check the safe functioning of the unit. To do so, bring about a sens or response by taking suitable measures. Display by LEDs: The red LED becomes active for a short time during the change between "medium not present" and "me[...]

  • Page 30

    SVL-A, SVL-B, SVL-C, & SVL-D Self-Contained Material Loaders - Venturi Style 30 of 49 Chapter 5: Maintenance Preparations  Please observe the maintenance intervals.  Before starting maintenance work, clean the equipment of oil, fuel or lubricants.  Ensure that materials and incidentals required for operation as well as spare parts are [...]

  • Page 31

    SVL-A, SVL-B, SVL-C, & SVL-D Self-Contained Material Loaders - Venturi Style 31 of 49 5-2 Cleaning the Conveying Filter WARNING! Disconnect power air sources. Always disconnect the main power source and compressed air source before removing the filter. This prevents the loader from starting during servicing, which could cause injury from flying[...]

  • Page 32

    SVL-A, SVL-B, SVL-C, & SVL-D Self-Contained Material Loaders - Venturi Style 32 of 49 4. Install/reinstall the filter. Firmly press down on the filter to make sure a good seal is provided around the entire perimeter of the filter module. The filter should fit evenly on the top of the loader body. 5-3 Cleaning the Comp ressed Air Filter The comp[...]

  • Page 33

    SVL-A, SVL-B, SVL-C, & SVL-D Self-Contained Material Loaders - Venturi Style 33 of 49 Disassembly 1. Remove the filter cartridge (A). 2. Blow out the filter cartridge (A) from the inside out using compressed air or replace the filter. 3. Open the toggle-type fastener (SVL-B, SVL-C models) (C) and fold the hopper lid upward. 4. Check the screen [...]

  • Page 34

    SVL-A, SVL-B, SVL-C, & SVL-D Self-Contained Material Loaders - Venturi Style 34 of 49 5-4 Troubleshooting PROBLEM REMEDY (See Test Steps Below) The unit is not conveying and is not active. A, B, G, H The unit is not conveying; the compressed air valve is activated when the device is switched on. C, D, E, F, N The unit is not conveying; the comp[...]

  • Page 35

    SVL-A, SVL-B, SVL-C, & SVL-D Self-Contained Material Loaders - Venturi Style 35 of 49 -Notes-[...]

  • Page 36

    SVL-A, SVL-B, SVL-C, & SVL-D Self-Contained Material Loaders - Venturi Style 36 of 49 Chapter 6: T echnical Dat a Maximum througput: 475 lbs/h (149.7 kg/hr) Weight: Approx. 6.61 lbs. (3 kg) Operating voltage:* 115 V, AC, PE, 50/60 Hz (standard) Special voltage on request Connected load: Approx. 2 W Total noise level: < 75 dB (A) Compressed a[...]

  • Page 37

    SVL-A, SVL-B, SVL-C, & SVL-D Self-Contained Material Loaders - Venturi Style 37 of 49 6-1 Dimension Sheet Figure 6.1: SVL-A[...]

  • Page 38

    SVL-A, SVL-B, SVL-C, & SVL-D Self-Contained Material Loaders - Venturi Style 38 of 49 Dimensions and data are not binding. All dimensions are in inches . All data are subject to change. Figure 6.2: SVL-B[...]

  • Page 39

    SVL-A, SVL-B, SVL-C, & SVL-D Self-Contained Material Loaders - Venturi Style 39 of 49 Dimensions and data are not binding. All dimensions are in inches. All data are subject to change. Figure 6.3: SVL-C[...]

  • Page 40

    SVL-A, SVL-B, SVL-C, & SVL-D Self-Contained Material Loaders - Venturi Style 40 of 49 Figure 6.4: SVL-D[...]

  • Page 41

    SVL-A, SVL-B, SVL-C, & SVL-D Self-Contained Material Loaders - Venturi Style 41 of 49 6-2 Spare Parts Lists . Figure 6.5: SVL-A[...]

  • Page 42

    SVL-A, SVL-B, SVL-C, & SVL-D Self-Contained Material Loaders - Venturi Style 42 of 49 Figure 6.6: SVL-B[...]

  • Page 43

    SVL-A, SVL-B, SVL-C, & SVL-D Self-Contained Material Loaders - Venturi Style 43 of 49 Figure 6.7: SVL-C[...]

  • Page 44

    SVL-A, SVL-B, SVL-C, & SVL-D Self-Contained Material Loaders - Venturi Style 44 of 49 Figure 6.8: Control Assembly Control Mounting Bracket[...]

  • Page 45

    SVL-A, SVL-B, SVL-C, & SVL-D Self-Contained Material Loaders - Venturi Style 45 of 49 Figure 6.9: Wand Assembly[...]

  • Page 46

    SVL-A, SVL-B, SVL-C, & SVL-D Self-Contained Material Loaders - Venturi Style 46 of 49 Figure 6.10: Take-Off Wand Assembly[...]

  • Page 47

    SVL-A, SVL-B, SVL-C, & SVL-D Self-Contained Material Loaders - Venturi Style 47 of 49 6-3 Quick Start Guide –SVL Self Contained Material Loader  Unpack all parts. Check for the following:  Material receiver with level sensor and mounting option  Control Assembly(s)  Venturi assembly(s)  Vinyl flexible hose(s)  Compressed air[...]

  • Page 48

    SVL-A, SVL-B, SVL-C, & SVL-D Self-Contained Material Loaders - Venturi Style 48 of 49 Technical Assistance Parts Department Call toll-free 7am–5pm CST [800] 423-3183 or [ 262 ] 641-8610, Fax [262] 641-8653 The ACS Customer Service Group will pr ovide your company with g enuine OEM quality parts manufactured to engineering design specification[...]

  • Page 49

    SVL-A, SVL-B, SVL-C, & SVL-D Self-Contained Material Loaders - Venturi Style 49 of 49[...]