Sub-Zero R364G manual

1
2
3
4
5
6
7
8
9

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Sub-Zero R364G, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Sub-Zero R364G one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Sub-Zero R364G. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Sub-Zero R364G should contain:
- informations concerning technical data of Sub-Zero R364G
- name of the manufacturer and a year of construction of the Sub-Zero R364G item
- rules of operation, control and maintenance of the Sub-Zero R364G item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Sub-Zero R364G alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Sub-Zero R364G, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Sub-Zero service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Sub-Zero R364G.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Sub-Zero R364G item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    W OLF D ESI GN GUID E[...]

  • Page 2

    W olf Gas Ranges 74 Gas Ranges. More than seven decades in the crucible of r estaurant kitchens have perfected the form, function and sheer durability of our gas ranges. These precision instruments ar e as noteworthy for their range of sizes and features as for their exhilarating performance. Standard featur es include an infrared broiler and conve[...]

  • Page 3

    W olf Gas Ranges 75 wolfappliance.com/specs Gas Ranges 30" (762) 37" (940) HEIGHT TO COOKING SURF ACE 36" (914) 37" (940) HEIGHT TO COOKING SURF ACE 60" (1527) RANGE 48" (1219) 37" (940) HEIGHT TO COOKING SURF ACE 60" (1524) 36" (914) 37" (940) HEIGHT TO COOKING SURF ACE 2 1 / 2 " (64) 24 1 / 2[...]

  • Page 4

    W olf Gas Ranges 76 Oven Specifications INTERIOR CAP ACITY CU FT (L) 18" (457) Oven 2.5 (71) 30" (762) Oven 4.4 (125) 36" (914) Oven 5.5 (156) INTERIOR DIMENSIONS W H D 18" (457) Oven 13 1 / 2 " (343) 18 5 / 8 " (473) 17" (432) 30" (762) Oven 24" (610) 18 5 / 8 " (473) 17" (432) 36" (914) [...]

  • Page 5

    GAS SUPPL Y REQUIREMENTS A gas supply line of 3 / 4 " (19) rigid pipe must be provided to the range. If local codes permit, a certified, 3' (.9 m) long, 1 / 2 " (13) or 3 / 4 " (19) ID flexible metal appliance connector is recommended to connect the units 1 / 2 " NPT female inlet to the gas supply line. W olf natural and LP[...]

  • Page 6

    W olf Gas Ranges 78 30 1 / 4 " (768) OPENING WIDTH 30" (762) TO 36" (914) TO BO TTOM OF VENTILA TION HOOD ** * Minimum clearance from rough opening to comb ustible materials up to 18" (457) abov e counter top . * *36" (914) minimum clearance from countertop to combustible materials without ventilation hood. NOTE: For island[...]

  • Page 7

    W olf Gas Ranges 79 wolfappliance.com/specs 36 1 / 4 " (921) OPENING WIDTH 30" (762) TO 36" (914) TO BO TTOM OF VENTILA TION HOOD ** * Minimum clearance from rough opening to comb ustible materials up to 18" (457) above countertop. * *36" (914) minimum clear ance, 44" (1118) for charbroiler , from counter top to combus[...]

  • Page 8

    W olf Gas Ranges 80 48 1 / 4 " (1226) OPENING WIDTH 30" (762) TO 36" (914) TO BO TTOM OF VENTILA TION HOOD ** * Minimum clearance from rough opening to comb ustible materials up to 18" (457) above countertop. * *36" (914) minimum clear ance, 44" (1118) for charbroiler , from counter top to combustib le materials withou[...]

  • Page 9

    W olf Gas Ranges 81 wolfappliance.com/specs 60 1 / 4 " (1530) OPENING WIDTH 30" (762) TO 36" (914) TO BO TTOM OF VENTILA TION HOOD ** * Minimum clearance from rough opening to comb ustible materials up to 18" (457) above countertop. * *44" (1118) minimum clearance from countertop to combustible materials without ventilation[...]