Subaru RGX7100 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Subaru RGX7100, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Subaru RGX7100 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Subaru RGX7100. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Subaru RGX7100 should contain:
- informations concerning technical data of Subaru RGX7100
- name of the manufacturer and a year of construction of the Subaru RGX7100 item
- rules of operation, control and maintenance of the Subaru RGX7100 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Subaru RGX7100 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Subaru RGX7100, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Subaru service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Subaru RGX7100.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Subaru RGX7100 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    3ZZ9990434 RGX3000 RGX3800 RGX5100 RGX7100 RGX7800 RGX3000 RGX3800 RGX5100 RGX7100 RGX7800 Original[...]

  • Page 2

    WARNING : The engine exhaust from this product contains chemicals known to the State of California to cause cancer, birth defects or other reproductive harm. DANGER (California Proposition 65) Only use OUTSIDE and far away from windows, doors, and vents. NEVER use inside a home or garage, EVEN IF doors and windows are open. Using a generator indoor[...]

  • Page 3

    WS6645 FEDERAL EMISSIONS COMPONENT DEFECT W ARRANTY EMISSIONS COMPONENT DEFECT WARRANTY COVERAGE – This emission warranty is applicable in all States, except the state of California. Fuji Heavy Industries Ltd. and Robin America Inc., Lake Zurich Illinois, (herein “ROBIN AMERICA”) warrant(s) to the initial retail purchaser and each subsequent [...]

  • Page 4

    ENGLISH FOREWORD Thank you for purchasing a Robin generator . This manual covers operation and maintenance of the Robin generators. All information in this publication is based on the latest production information available at the time of approval for printing. Pay special attention to statements preceded by the following words: ■ The generator i[...]

  • Page 5

    CONTENTS 1. SAFETY PRECAUTIONS ・・・・・・・・・・・・・・・・ 1 2. SPECIFICA TIONS ・・・・・・・・・・・・・・・・・・・ 3 3. COMPONENTS ・・・・・・・・・・・・・・・・・・・・ 4 4. PRE-OPERA TION CHECKS ・・・・・・・・・・・・・・・ 7 5. OPERA TING PROCEDURES ・・・・?[...]

  • Page 6

    1. SAFETY PRECAUTIONS − 1 − ENGLISH Please make sure you review each precaution carefully. Do not operate the generator near gasoline or gaseous fuel because of the potential danger of explosion or fire. Do not fill the fuel tank with fuel while the engine is running. Do not smoke or use open flame near the fuel tank. Be careful not to spill fu[...]

  • Page 7

    − 2 − Do not contact the generator to a commercial power line. Connection to a commercial power line may short circuit the generator and ruin it or cause electric shock hazard. Use the transfer switch for connecting to domestic circuit. WARNING Engine becomes extremely hot during and for some time after operation. Keep combustible materials wel[...]

  • Page 8

    2. SPECIFICA TIONS − 3 − ENGLISH MODEL T ype Starting system L mm mm mm mL L kg Model T ype Vo ltage regulating system VA (W) Rated output Rated current AC Output Rated voltage Fuel tank capacity Engine oil capacity Spark plug Dry weight Specifications are subject to change without notice. *1: ( ) shows the filled amount up to the "LEVEL&q[...]

  • Page 9

    3. COMPONENTS − 4 − Fuel tank Fuel gauge Engine switch Choke lever Oil drain plug Oil gauge (oil filler) Spark plug cap Air cleaner Exhaust outlet Tank cap Fuel strainer ( Fuel valve ) Muffler cover Recoil starter Recoil starter handle Control panel RGX3000, 3800, 5100 RGX7800 ce_GU6809 09.9.17 6:00 PM ページ4[...]

  • Page 10

    − 5 − ENGLISH Control panel Fuel tank Fuel gauge Engine switch Recoil starter handle Choke lever Oil gauge (oil filler) Spark plug cap Air cleaner Muffler Tank cap Recoil starter Muffler cover Oil drain plug RGX7100, 7800 RGX7800 ce_GU6809 09.9.17 6:00 PM ページ5[...]

  • Page 11

    − 6 − ï (RGX3000) (RGX5100, 7100, 7800) (RGX3800) Pilot lamp AC receptacle 20A Earth ( ground ) terminal AC circuit breaker AC circuit breaker Hour meter DC receptacle DC circuit breaker DC circuit breaker AC receptacle 30A AC receptacle 20A Engine switch [Electric starter model] Engine switch Pilot lamp Earth ( ground ) terminal AC circuit br[...]

  • Page 12

    4. PRE-OPERA TION CHECKS − 7 − ENGLISH Upper level Oil filler cap (Oil gauge) Lower level CHECK ENGINE OIL Before checking or refilling oil, be sure generator is located on stable and level surface with engine stopped. ■ Remove oil filler cap and check the engine oil level. ■ If oil level is below the lower level line, refill with suitable [...]

  • Page 13

    − 8 − ■ Check fuel level at fuel level gauge. ■ If fuel level is low , refill with unleaded automotive gasoline. ■ Be sure to use the fuel filter screen on the fuel filter neck. LEVEL Fuel filter screen Fuel tank cap FULL EMPTY EMPTY FULL EF RGX7100 RGX7800 RGX3000 RGX3800 RGX5100 Do not refuel while smoking or near open flame or other su[...]

  • Page 14

    − 9 − ENGLISH CHECKING COMPONENT P ARTS Check following items before starting engine: ■ Fuel leakage from fuel hose, etc. ■ Bolts and nuts for looseness. ■ Components for damage or breakage. ■ Generator not resting on or against any adjacent wiring. CHECK GENERA TOR SURROUNDINGS Make sure you review each warning in order to prevent fire[...]

  • Page 15

    − 10 − GROUNDING THE GENERA TOR ■ To ground the generator to the earth, connect the grounding lug of the generator to the grounding spike driven into the earth or to the conductor which has been already grounded to the earth. ■ If such grounding conductor or grounding electrode is unavailable, connect the grounding lug of the generator to t[...]

  • Page 16

    5. OPERA TING PROCEDURES − 11 − ENGLISH (a) T urn the Engine switch to the position "ON". (b) T urn the AC circuit breaker to the position "OFF". (c) Open the fuel valve. (d) Set choke lever to close if the engine is cold. ST ARTING THE GENERA TOR Check the oil level before each operations as outlined by the article "CH[...]

  • Page 17

    − 12 − Pull briskly (e) [ Recoil starter model] Pull the starter handle slowly until passing the compression point (resistance will be felt), then return the handle to its original position and pull briskly . ■ If the engine fails to start after several attempts, repeat above procedures with choke lever returned to "OPEN" position. [...]

  • Page 18

    − 13 − ENGLISH (g ) After the engine started, return the choke lever gradually to "OPEN" position. Choke lever CLOSE OPEN (h) W arm up the engine without a load for a few minutes. RGX7800 ce_GU6809 09.9.17 6:00 PM ページ13[...]

  • Page 19

    − 14 − (a) Make sure the pilot lamp is turned on. (b) T urn off the switch (es) of the electrical appliance (s) before connecting to the generator . (c) Insert the plug (s) of the electrical appliance(s) into the receptacle. (1) AC APPLICA TION USING ELECTRIC POWER ■ Make sure that the appliance is switched OFF before connecting it to the gen[...]

  • Page 20

    − 15 − ENGLISH TABLE 1 NOTE : When the AC circuit breaker turns off during operation, the generator is over loaded or the appliance is defective. Stop the generator immediately , check the appliance and / or generator for overloading or detect and have repaired as necessary by Robin dealer or service shop. ■ To take power out from the TWIST L[...]

  • Page 21

    − 16 − (d) T urn the AC circuit breaker to the position "ON". (e )T urn on the switch of the appliance. ON ON OFF GFCI RECEPT ACLE After starting the engine, check the GFCI for proper functioning by the following test procedure. ■ Push blue TEST button, The red RESET button will pop out exposing the word TRIP . Power is now off at t[...]

  • Page 22

    − 17 − ENGLISH Switch position Lower V oltage Receptacle Higher V oltage Receptacle 120V Activated full rated output N.A 120/240V Activated half of rated output Activated full rated output FULL POWER SWITCH (Except RGX3000) Select the voltage using the FULL POWER SWITCH in accordance with the electrical appliance. Refer to T ABLE 2 . 120V 120V [...]

  • Page 23

    − 18 − IDLE CONTROL SWITCH (Except RGX3000) IDLE CONTROL SWITCH automatically reduces engine speed when load is OFF , and automatically increases engine speed to rated r .p.m. when load is ON. IDLE CONTROL SWITCH provides fuel economy and low noise operation at no- load running. (1) HOW TO USE IDLE CONTROL SWITCH ■ Start the engine with IDLE [...]

  • Page 24

    − 19 − ENGLISH (2) DC APPLICA TION (Only for charging 12 volt battery) DC receptacle (Only for charging 12 volt battery) For charging 12 voltage battery , 12V -8.3A (100W) of maximum AC power can be taken out from the DC receptacle by means of the exclusive DC cable. The exclusive DC cable is come with your generator set (included in the packag[...]

  • Page 25

    − 20 − ■ Do not use both AC and DC output at the same time. ■ Install correct positive (red) or negative (black) cable to the correct polarity on the battery . ■ Connect and disconnect DC cable with engine stopped. ■ An explosive hydrogen gas is discharged through vent holes in the battery during the charging process. Do not allow spark[...]

  • Page 26

    − 21 − ENGLISH STOPPING THE GENERA T OR (a) T urn off the power switch of the electric equipment and unplug the cord from receptacle of the generator . (b) T urn the AC circuit breaker to the "OFF" position. (c) Allow the engine about 3 minutes to cool down at no-load before stopping. (d) [ Recoil starter model ] T urn the engine [...]

  • Page 27

    6. W A TT AGE INFORMA TION − 22 − Some appliances need a "surge" of energy when starting. This means that the amount of electrical power needed to start the appliance may exceed the amount needed to maintain its use. Electrical appliances and tools normally come with a label indicating voltage, cycles / Hz, amperage (amps) and electri[...]

  • Page 28

    − 23 − ENGLISH VOL T AGE DROP IN ELECTRIC EXTENSION CORDS When a long electric extension cord is used to connect an appliance or tool to the generator , a certain amount of voltage drop or loss occurs in the extension cord which reduces the effective voltage available for the appliance or tool. The chart below has been prepared to illustrate th[...]

  • Page 29

    7. SP ARK ARRESTER − 24 − In a dry or wooded area, it is recommendable to use the product with a spark arrester . Some areas require the use of a spark arrester . Please check your local laws and regulations before operating your product . The spark arrester must be cleaned regularly to keep it functioning as designed. A clogged spark arrester [...]

  • Page 30

    8. MAINTENANCE SCHEDULE − 25 − ENGLISH DAIL Y INSPECTION Before running the generator , check the following service items: Excessive vibration,noise Clean air cleaner element Safe surroundings Enough clean engine oil Leakage of gasoline and engine oil Loose or broken bolts and nuts Enough gasoline PERIODIC MAINTENANCE Periodic maintenance is vi[...]

  • Page 31

    − 26 − *Note: 1. Initial oil change should be performed after first twenty (20) hours of operation. Thereafter change oil every hundred (100) hours. Before changing oil, check for a suitable way to dispose of old oil. Do not pour it down into sewage drains, onto garden soil or into open streams. Your local zoning or environmental regulations wi[...]

  • Page 32

    9. "HOW -TO" MAINTENANCE − 27 − ENGLISH ENGINE OIL CHANGE ■ Change engine oil every 100 hours. (For new engine, change oil after 20 hours.) (a) Drain oil by removing the drain plug and the oil filler cap while the engine is warm. Oil drain plug (b) Reinstall the drain plug and fill the engine with oil until it reaches the upper leve[...]

  • Page 33

    − 28 − CLEANING AND ADJUSTING SP ARK PLUG (a) If the plug is contaminated with carbon, remove it using a plug cleaner or wire brush. (b) Adjust the electrode gap to 0.6 to 0.7 mm (0.024 to 0.028 in.). Gap 0.6 to 0.7 mm ( 0.024 to 0.028 in. ) CLEANING FUEL STRAINER Dirt and water in the fuel are removed by the fuel strainer . (a) Remove the stra[...]

  • Page 34

    − 29 − ENGLISH This is done because if the length of the brush gets any shorter , its contact pressure with the slip ring will decrease, resulting in a drop in generator efficiency and the output voltage. Check the brush every 500 hours to confirm its length. In addition, check the brush length if the generator malfunctions, such as when it is [...]

  • Page 35

    − 30 − Brush Maintenance Essentials (Disassembly and Assembly) Disassembly 1. Remove the two flange bolts (M5 x 20), then remove the bracket cover . 2. Remove the two flange bolts (M5 x 16), then remove the brush. Assembly 1. While pressing the brush against the slip ring, secure it (1.5~2N ・ m) by tightening it with the two flange bolts (M5 [...]

  • Page 36

    10. PREP ARA TION FOR ST ORAGE − 31 − ENGLISH The following procedures should be followed prior to storage of your generator for periods of 6 months or longer . ■ Drain fuel from fuel tank carefully by disconnecting the fuel line. Gasoline left in the fuel tank will eventually deteriorate making engine- starting difficult. ■ Remove the carb[...]

  • Page 37

    11 . TROUBLESHOOTING − 32 − When generator engine fails to start after several attempts, or if no electricity is available at the output socket, check the following chart. If your generator still fails to start or generate electricity , contact your nearest Robin dealer or service shop for further information or corrective procedures. When Engi[...]

  • Page 38

    12. WIRING DIAGRAM − 33 − ENGLISH PL AC   winding 2 AC   winding 1 Y Y Grn/Y Org Y/R Blk RR R Blu Blu Gry Grn/Y Grn/Y Blk Ignition coil Oil sensor switch Spark plug Oil sensor unit Y Blk W W W Brn Y Y Blu Brn Brn Y Blu Blu Brn ROTOR S TATO R Slip ring Sub coil DC winding AV R u n i t Bridge diode DC Output receptacle DC circuit breaker DC12[...]

  • Page 39

    − 34 − PL AC winding 2 AC winding 1 Y Y Grn/Y Org Y/R Blk RR R Blu Blu Gry Grn/Y Grn/Y Blk Ignition coil Oil sensor switch Spark plug Oil sensor unit Y Blk WW W W Brn Y Y Blu Brn Brn Y Blu Blu Brn ROTOR S TATO R Slip ring Sub coil DC winding AV R u n i t Bridge diode DC Output receptacle DC circuit breaker DC12V Earth (Ground) terminal Pilot la[...]

  • Page 40

    − 35 − ENGLISH 1 3 4 2 5 Org Y/R Blk Blk Ignition coil Oil sensor switch Spark plug Oil sensor unit W W Y Slowdown solenoid AC winding 2 AC winding 1 Y Y Grn/Y Brn Y Y Brn Brn Y Blu Blu Brn ROTOR S TATO R Slip ring Sub coil DC winding AV R unit Bridge diode RR R Blu Blu Gry Gry W W Blk Blk Org Grn/Y Grn/Y Battery Electric starter Magnetic switc[...]

  • Page 41

    − 36 − PL AC winding 2 AC winding 1 Grn/Y Org Y/R Blk RR Blu Blu Gry Grn/Y Grn/Y Blk Ignition coil Oil sensor switch Spark plug Oil sensor unit Y Blk W W W Brn Blu Blu Blu Blu R Grn Grn W WW Brn ROTOR S TATO R Slip ring Sub coil DC winding AV R u n i t Bridge diode DC Output receptacle DC circuit breaker DC12V Earth (Ground) terminal Pilot lamp[...]

  • Page 42

    − 37 − ENGLISH PL 1 3 4 2 5 GENERA TOR CONTROL BOX ENGINE Org Y/R Blk Blk Ignition coil Oil sensor switch Spark plug Oil sensor unit W W Y Slowdown solenoid AC winding 2 AC winding 1 Blu Blu Grn/Y Brn Blu Blu R Grn Grn W W W Brn ROTOR S TATO R Slip ring Sub coil DC winding AV R unit Bridge diode RR Blu Blu Gry Grn/Y W W Blk Blk Org Gry Org Grn/[...]

  • Page 43

    RGX7800 ce_GU6809 09.9.17 6:00 PM ページ38[...]

  • Page 44

    PRINTED IN JAPAN ISSUE EMD-GU6809 September 2009 IMPRESO EN JAPÓN Septiembre 2009 RGX7800 cs_GU6809 09.9.17 6:02 PM ページ40[...]