Go to page of
Similar user manuals
-
Computer Drive
Sun Microsystems SUN BLADE 150
20 pages 1.21 mb -
Computer Drive
Sun Microsystems SUN NETRA CP3000
72 pages 1.77 mb -
Computer Drive
Sun Microsystems 6900 Series
162 pages 1.15 mb -
Computer Drive
Sun Microsystems CP32x0
66 pages 1.99 mb -
Computer Drive
Sun Microsystems VSM GUI
68 pages 0.6 mb -
Computer Drive
Sun Microsystems StorageTek 96257
118 pages 2.01 mb -
Computer Drive
Sun Microsystems 5210 NAS
100 pages 0.97 mb -
Computer Drive
Sun Microsystems STOREDGE A5000
2 pages 0.09 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Sun Microsystems StorageTek HP LTO4, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Sun Microsystems StorageTek HP LTO4 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Sun Microsystems StorageTek HP LTO4. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Sun Microsystems StorageTek HP LTO4 should contain:
- informations concerning technical data of Sun Microsystems StorageTek HP LTO4
- name of the manufacturer and a year of construction of the Sun Microsystems StorageTek HP LTO4 item
- rules of operation, control and maintenance of the Sun Microsystems StorageTek HP LTO4 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Sun Microsystems StorageTek HP LTO4 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Sun Microsystems StorageTek HP LTO4, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Sun Microsystems service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Sun Microsystems StorageTek HP LTO4.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Sun Microsystems StorageTek HP LTO4 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
Sun StorageTek TM Crypto Key Management System HP LTO4 Encryption-Capable Tape Drives Technical Brief Part Number: 316196601 Revision: A[...]
-
Page 2
[...]
-
Page 3
Sun Microsystems, Inc. www .sun.com Cr ypto K e y Management System V ersion 2.0 HP L T O4 T ape Driv e T echnical Br ief P art Number : 316196601 June 2008 Revision: A[...]
-
Page 4
Copyright © 2008 Su n Microsyste ms, Inc., 4150 Network Cir cle, Santa Clara , California 95 054, U.S.A. All ri ghts rese rved. Sun Microsyste ms, Inc. has intellectual pr operty rights relating to technology embodied in th e product that is described in thi s document.In particular , and without limitation, these intellectual property rights may [...]
-
Page 5
316196601 • Revision: A iii Contents Preface v Organization v Related Information v Additional Information vi 1. Introduction 1 Drive Tray 2 Specifications 3 Compatibility 5 Order Numbers 6 2. Dione Card 7 Firmware Requirements 7 Dione Card Com ponents 8 Connecting to the Dione Card 9 KMS Operations 10 Key Lifecycle 10 Media RFID Chips 12 Media T[...]
-
Page 6
iv KMS: LTO4 Technical Brief • June 20 08 Revision: A • 316196601 Using VOP 19 Start VOP 20 Diagnose Drive Tab 23 Run LED Diagno stic T est 23 Run Loopback T est 24 Get Log 25 Load Firmware 25[...]
-
Page 7
316196601 • Revision: A v Pr eface This technical brief is intended for Sun StorageT ek TM r epresentatives, customers, and anyone r esponsible for planning the installation of the Cr ypto Key Management System (KMS ) encryption solution. Or ganization Related Information These publications co ntain th e additional information: This guide has the[...]
-
Page 8
Preface vi KMS: LTO4 Technical Brief • June 2008 Revision: A • 316196601 Additional Information Sun Microsystems, Inc. (Sun) of fers se veral methods to obtain additional information. Sun’s External W eb Site Sun’s external W eb site pr ovides marketing, product, event, corporate, and service information. The ex ternal W eb site is acce ss [...]
-
Page 9
316196601 • Revision: A 1 CHAPTER 1 Intr oduction Overview The Hewlett Packard (HP) L TO4 is the fourth-generat ion of Ultrium, Linear T ape-Open tape drives. This generation of fers more capacity and incr eased performance than e arlier versions of L TO tape drives. Encryption Capable The Hewlett Packard L TO4 is the first , non-StorageT ek T -S[...]
-
Page 10
Drive Tray 2 KMS: LTO4 Technical Brief • June 2 008 Revision: A • 316196601 Installing this tape drive in one of Sun St orageT ek’s autom ated tape configurations offe rs customers wi th an even wider ch oice of tape-based storage solutions. ■ Server compatibility: Fibre Channel an d SCSI models on popular (qualified ) p l a t f o r m s f r[...]
-
Page 11
316196601 • Revision: A Chapter 1 Introduction 3 Specific ations Specifications T ABLE 1- 1 provides a comparison of tape drive specifications. T ABLE 1-1 T ape Drive Specifications LT O 2 LT O 3 LT O 4 Physical Specifications Height 8.25 cm (3.25 in.) 8.25 cm (3.25 in.) 8.25 cm (3.25 in.) W idth 14.6 cm (5.75 in.) 14.6 c m (5.75 in.) 14.6 cm (5.[...]
-
Page 12
Specifications 4 KMS: LTO4 Technical Brief • June 2 008 Revision: A • 316196601 TA B L E 1-2 provides a comparison of media specifications. T ABLE 1-3 lists the reliabilit y specifications. T ABLE 1-2 Media Specifications Specification LT O 2 LT O 3 LT O 4 T ape Base film PEN (Poly-Ethylene-Naphthalate) Ta p e l e n g t h 609m 680m 820m T ape l[...]
-
Page 13
316196601 • Revision: A Chapter 1 Introduction 5 Specific ations Compatibility HP L TO Ultrium 4 drives are specified to inter change with un-encrypted data c a r t r i d g es f r o m o t h e r t a p e d r i v e s t h a t comply to the L TO U-28, U-316 and U-416 specifications: Future compatibility: In the future, HP L TO Ultrium drives will be c[...]
-
Page 14
Order Numbers 6 KMS: LTO4 Technical Brief • June 2 008 Revision: A • 316196601 Or der Numbers License Keys Configured E nd Items X-Options (Conversion Bills) Dione Card FIGURE 1-2 License Ke ys L T O4 Encryption Key Marketing Number Description Bundled X-HP-L TO4-EKEY -B One r equir ed per encrypti on enabled dri ve. Bundled with the drive at t[...]
-
Page 15
316196601 • Revision: A 7 CHAPTER 2 Dione Car d The Dione card—pr onounced (D - O - nee)—i s a custom d esign that provides an Ethernet interface fo r the HP L TO4 tape dr ive. W ith this inte rface, th e HP L TO4 tape drive can: ■ Encrypt and decrypt data using the Su n StorageT ek Crypto Key Management System (KMS), V ersion 2.0 and above[...]
-
Page 16
Dione Card Components 8 KMS: LTO4 Technical Brief • June 2 008 Revision: A • 316196601 Dione Car d Components The Dione card installs in the open ar ea of the drive trays behind the tape drives. Library drive trays that support this card ar e the: ■ SL8500 ■ SL3000 ■ SL500 ■ L-Series Each drive tray has its own unique conf iguration dep[...]
-
Page 17
316196601 • Revision: A Chapter 2 Dione Card 9 Dione Card Components Connecting to the Dione Car d FIGURE 2-2 shows two ways to conn ect to the Dione card: ■ Point-to-point usin g a crossover cable ■ Network using a switch or hub and standa rd (straight-through) Ethernet cables Note – The default I P addre ss of the Dione car d is 10.0.0.1 [...]
-
Page 18
KMS Operations 10 KMS: LTO4 Technical Brief • June 2008 Revision: A • 316196601 KMS Operations When the tape drive is powered-on, th e Dione card co mmunicates to the dr ive o v e r t h e s er i a l p o r t t o t a k e c o n t r o l of drive encryption and decryption. HP L TO4 tape drives have the capability of storing one (1) key while encrypt[...]
-
Page 19
316196601 • Revision: A Chapter 2 Dione Card 11 KMS Operations A potential issue: Th a t L TO 4 dr i v e fi r m w are w i l l n o t re qu e s t a write key in the following scenario: Read, Space, W rite-Filemark, W rite. The drive will use the same key obtained for the Read command to encrypt the data pr ovided for the W rite command. Th e state [...]
-
Page 20
KMS Operations 12 KMS: LTO4 Technical Brief • June 2008 Revision: A • 316196601 At release, the functionality to set a ke y in a compr omised state is not present. This is a low impact issu e due to the syst em assi gning unique encryption keys for e a c h t a p e c a r t r i d g e . I t i s r a r e t h a t a c o m p r o m i s e d k e y s c e n[...]
-
Page 21
316196601 • Revision: A Chapter 2 Dione Card 13 KMS Operations FIGURE 2-4 prov ides an example of a KMS Manager display sc reen using the elements from and HP L TO4 drive. FIGURE 2-4 K M S M a n a g e r D a t a U n i t L i s t 1. Data Unit ID (data cartridge) 2. External T ag (volume serial number) 3. Description (L TO4 or L TO4WORM) 4. External [...]
-
Page 22
Removal and Replacemen t 14 KMS: LTO4 Technical Brief • June 2008 Revision: A • 316196601 Removal and Replacement Encryption-capable HP L TO 4 tape drives contain an Ethernet card, wh ich is a field repla ceable unit (FRU). Depending on the library , each drive tray contains the card in a differ ent location; however , the removal and replaceme[...]
-
Page 23
316196601 • Revision: A Chapter 2 Dione Card 15 Removal and Replacement 3. Place the drive and drive tray on a suitable work surface. 4. Remove the two T9 screws fr om the top cover and remove the cover . 5. Remove the connecto rs fr om the HBD car d. 6. Remove the four T10 screws th at attach the drive to the tray . 7. Remove the T10 screw that [...]
-
Page 24
Removal and Replacemen t 16 KMS: LTO4 Technical Brief • June 2008 Revision: A • 316196601[...]
-
Page 25
316196601 • Revision: A 17 CHAPTER 3 V irtual Operator Panel The Sun StorageT ek V irtual Operator Pane l (VOP) is a computer-based application that provides a graphical user interface (GUI) to these tape drives: ■ T10000A ■ T10000B ■ T9840D W ith the VOP at V ersion 1.0.12 and higher , support for the HP L T O4 tape drive is provided thr o[...]
-
Page 26
18 KMS: LTO4 Technical Brief • June 2008 Revision: A • 316196601 The VOP application uses an Ethernet connec tion to communicate with the tape drives, either: ■ Point-to-point, using a cross-over cable ■ Networked, using a switch and standard—straight—Ethernet cables This Ethernet interface provides communic ation with the tape drives a[...]
-
Page 27
316196601 • Revision: A Chapter 3 Virtual Operator Pan el 19 Using VOP Using VOP Ther e are two v e rsions of VOP: 1) Customer an d 2) Se rvice. Refer to the VOP documentation for in formation about how to download and install these applications. TA B L E 3-1 is an example of th ese versions. For the initial configuration, use a secure point-to-p[...]
-
Page 28
Using VOP 20 KMS: LTO4 Technical Brief • June 2008 Revision: A • 316196601 Start VOP Importa nt: ■ Remember , the Service Delivery Platform (SDP) doe s not support the L TO4 drives. Y o u may need to make adjustments to the network add resses if mixing t a p e d r i v e s o n t h e s a m e K M A a n d / o r S D P n e t w o r k ( L A N 2 ) . ?[...]
-
Page 29
316196601 • Revision: A Chapter 3 Virtual Operator Pan el 21 Using VOP 5. Select the Configure Drive tab and enter the r equired information. Y ou w ill need customer input for the KMA ID, IP Address, and Passphrase. 6. Click Commit and r espond “Y es” to the set drive offline pop-up (if still online). The commit process takes about 30 second[...]
-
Page 30
Using VOP 22 KMS: LTO4 Technical Brief • June 2008 Revision: A • 316196601 During the com mit proces s, the tape d rive goes of fline then IPLs to save th e new settings to the Dione card. Impor tant: When the drive comes back online, it is now using the new IP addr ess. 8 . T o c o n t i n u e w i t h t h e c o n f i g u r a t i o n a n d t o [...]
-
Page 31
316196601 • Revision: A Chapter 3 Virtual Operator Pan el 23 Diagnose Drive Tab Diagnose Drive T ab The Dione car d and the VOP Diagnose Driv e tab allow you to perform limit tests, get logs for engine ering review , an d to load Dione card firmware. Run LED Diagnostic T est T o run the LED diagnostic test: 1. Click on Run LED Diag. The display c[...]
-
Page 32
Diagnose Drive Tab 24 KMS: LTO4 Technical Brief • June 2008 Revision: A • 316196601 Run Loopback T est T o run the Loopback diagnostic tes t: 1. Click on Run Loopb ack T est. 2. Observe the displa y as the test starts and ends. FIGURE 3-8 Run LED Diag[...]
-
Page 33
316196601 • Revision: A Chapter 3 Virtual Operator Pan el 25 Diagnose Drive Tab Get Log I f a D i o n e c a r d o r c o n n e c t i o n i s c o n s i s tently having problems, engineer ing may request you retrieve a log of events from the Dione card. 1. Click Get Log. 2. Create and select a location for the file. Once the file has trans ferre d, [...]
-
Page 34
Diagnose Drive Tab 26 KMS: LTO4 Technical Brief • June 2008 Revision: A • 316196601[...]
-
Page 35
316196601 • Revision: A 27 Index B batch file ,1 9 C cartridge memory ,1 2 comparisons LT O t a p e d r i v e s ,3 media ,4 compatibility , media ,5 compliance regulations ,2 Configure Drive tab ,2 1 connecting to a Dione card ,9 conversion bills ,6 D Data Unit ,1 2 default IP addr ess ,9 , 2 0 Dione card ,7 components ,8 connections to ,9 defaul[...]
-
Page 36
28 KMS: L TO4 T echnica l Brief • June 2008 Revision: A • 31 6196601 overview ,1 specifications ,3 LT O 4 i n t e r f a c e s ,1 M manual organization ,v manuals ,v media encryption-capability ,5 intr oduction ,1 RFID chip ,1 2 Mid-range class ,2 Monitor Drive tab ,1 7 N NIST 800-57 guidelines ,1 0 O operating systems, VOP ,1 8 order numbers ,6[...]
-
Page 37
[...]
-
Page 38
SU N™ THE NETWORK IS THE COMPUTER ©2006 Sun Microsystems , Inc. All rights reserved. Sun, Sun Microsystems, and the Sun logo ar e trademarks or registered trademarks of Sun Microsystems , Inc. in the United States and other countries. Sun Microsys tems, Inc. 4150 Network Cir cle, Santa Clara, CA 95054 USA Phone 1 - 650 - 960-1300 or 1-800- 555- [...]