Go to page of
Similar user manuals
-
Server
Sun Microsystems T5220
42 pages 1.49 mb -
Server
Sun Microsystems Sun Blade T6300
20 pages 0.85 mb -
Server
Sun Microsystems 880
34 pages 0.26 mb -
Server
Sun Microsystems V40z
216 pages 6.6 mb -
Server
Sun Microsystems V20z
216 pages 6.6 mb -
Server
Sun Microsystems 2.1
184 pages 0.91 mb -
Server
Sun Microsystems T6300
52 pages 0.4 mb -
Server
Sun Microsystems Netra 120
200 pages 5.23 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Sun Microsystems X6440, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Sun Microsystems X6440 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Sun Microsystems X6440. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Sun Microsystems X6440 should contain:
- informations concerning technical data of Sun Microsystems X6440
- name of the manufacturer and a year of construction of the Sun Microsystems X6440 item
- rules of operation, control and maintenance of the Sun Microsystems X6440 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Sun Microsystems X6440 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Sun Microsystems X6440, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Sun Microsystems service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Sun Microsystems X6440.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Sun Microsystems X6440 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
Sun Microsystems, Inc. www .sun.com Submit comments about this document by clic king the Feedbac k[+] link at: http://docs.sun.com Sun Blade ™ X6440 Ser v er Module Product Notes V ersion 2.0 P ar t No . 820-3965-15, Rev . A Nov ember 2009[...]
-
Page 2
Please Recycle Copyright © 2009 Sun Microsystems, Inc., 4150 Network Cir cle, Santa Clara, California 95054, U.S.A. All rights reserved. Sun Microsystems, Inc. has intellectual pr operty rights relating to technology embodied in the product that is described in this document. In particular , and without limitation, these intellectual property righ[...]
-
Page 3
1 Sun Blade X6440 Server Module Pr oduct Notes This document contains late-breaking information and issues for the Sun Blade™ X6440 server module. The following is covered in these pr oduct notes: ■ “General Information” on page 2 ■ “Sun Blade X6440 Server Module T ools & Drivers DVD” on page 4 ■ “Latest Firmware Updates” on[...]
-
Page 4
2 Sun Blade X6440 Server Module Product Notes • November 2009 General Information Support and Patches for Sun Blade Server Modules Support information for the Sun Blade X6440 server module is available at: http://sunsolve.sun.com Supported Operating Systems The following is a list of the minimum versions of supported operating systems for the Sun[...]
-
Page 5
Sun Blade X6440 Server Module Product Notes 3 Documentation Support documentation for the Sun Blade X6440 server module: ■ Sun Blade X6440 Server Module Installation Guide (820-3961) ■ Sun Blade X6440 Server Module Product Notes (820-3965) ■ Sun Blade X6440 Server Module Operating Systems Installation Guide (820-3962) ■ Sun Blade X6440 Serv[...]
-
Page 6
4 Sun Blade X6440 Server Module Product Notes • November 2009 Sun Blade X6440 Server Module T ools & Drivers DVD The Sun Blade X6440 Server Module T ools & Drivers DVD contains several software applications and utilities for use with your Sun Blade X6440 server module. This section describes the applications and utilities and refers you t[...]
-
Page 7
Sun Blade X6440 Server Module Product Notes 5 Newly Supported Featur es The following new features are supported as of supplemental softwar e release 2.0: ■ Integrated Lights Out Manager 3.0 ■ Sun ILOM Remote Console Lock ■ Sun ILOM Power Management Integrated Lights Out Manager 3.0 The Sun Blade X6440 server module supports Integrated Lights[...]
-
Page 8
6 Sun Blade X6440 Server Module Product Notes • November 2009 Sun ILOM Remote Console Lock The Sun Blade X6440 server module supports the Sun ILOM Remote Console lock. The Sun ILOM Remote Console lock feature enhances your system security by enabling you to lock your computer when terminating a Sun ILOM Remote Console session. For more informatio[...]
-
Page 9
Sun Blade X6440 Server Module Product Notes 7 ILOM BIOS settings issue If ILOM is set to use a DHCP assigned IP address, and the DHCP server is off line, wait until the DHCP server is online before attempting to reboot. Issuing a r eboot or manually changing from DHCP to a static IP addr ess will result in incorrect gateway and IP address settings [...]
-
Page 10
8 Sun Blade X6440 Server Module Product Notes • November 2009 Blade server module fails to link up at 1GbE If the Sun Blade X6440 server module is inserted into certain slots in the Sun Blade 6048 chassis, it fails to link up at 1GbE with the X5196A-Z Sun Blade 6048 Infiniband Switched Network Express Module (NEM). This issue occurs primarily on [...]
-
Page 11
Sun Blade X6440 Server Module Product Notes 9 Certain devices’ boot option ROM fails to load A shadow ROM space issue exists when multiple bootable devices are installed in the system. Not all devices’ bootable option ROMs will successfully load. W orkaround: This issue is fixed in the T ools & Drivers DVD 1.2 and later software release. Us[...]
-
Page 12
10 Sun Blade X6440 Server Module Product Notes • November 2009 L VM partitioning is not supported when installing SLES 10 SP2 operating system Change Request ID: 6780100 If L VM disk partitioning is selected when installing the SLES 10 SP2 operating system using SIA, the installation will fail because the platform drivers will not install correct[...]
-
Page 13
Sun Blade X6440 Server Module Product Notes 11 W orkaround: None SIA will not install FEM drivers for W indows 2003 Change Request ID: 6769562 If SIA is used to install W indows 2003 on a system that contains the model x1029 A FEM, the associated device will be highlighted with a yellow question mark in the W indows Device Manager , indicating that[...]
-
Page 14
12 Sun Blade X6440 Server Module Product Notes • November 2009 When installing the Linux operating system using SIA version 2.3.8, the System Information screen displays incorrect information for the chassis type, serial number , and version number . This issue will be fixed in future softwar e release. SIA does not display storage contr ollers C[...]
-
Page 15
Sun Blade X6440 Server Module Product Notes 13 SIA does not install operating systems via PXE server Change Request ID: 6876850 When using SIA version 2.3.8 to install OSes via a PXE server , SIA displays the following error message during the OS installation: Error enabling swap device sda2: Invalid argument This error af fects all OS installation[...]
-
Page 16
14 Sun Blade X6440 Server Module Product Notes • November 2009 Delaying BIOS Upgrade During Firmwar e Update Can Corrupt BIOS The ILOM SP firmwar e upgrade procedure includes the Delay BIOS Update option, which delays the BIOS update until the host is reset. This option allows you to update the firmwar e without resetting the host. The following [...]
-
Page 17
Sun Blade X6440 Server Module Product Notes 15 Minimum Supported Br owsers T ABLE 1 shows the minimum supported browser versions for running the Integrated Lights Out Manager (ILOM) web interface for the Sun Blade X6440 server module on Solaris and Linux operating systems. No warning when passwor d length is exceeded No errors or warnings ar e issu[...]
-
Page 18
16 Sun Blade X6440 Server Module Product Notes • November 2009 ● If you are logged in as root, choose to open the f ile with its default application. –or– ● If you are logged in as a user (not root), do the following: 1. Choose the option to save the f ile. 2. Download the javaRKVM.jnlp f ile and run it manually . The download manager wil[...]
-
Page 19
Sun Blade X6440 Server Module Product Notes 17 Err or message appears during service pr ocessor startup The following error message may appear during service pr ocessor (SP) startup: Mike driver. insmod: cannot insert ‘/lib/modules/2.6.15.4/misc/mtd_mike/mike.ko’: No such device (- 1): No such device modprobe: failed to load module mike This is[...]
-
Page 20
18 Sun Blade X6440 Server Module Product Notes • November 2009 Har d disk err or message in the SP event log The following error message might appear in the SP event log when no har d disk is installed. System Firmware Error | Unrecoverable hard-disk controller failure | Asserted W orkaround: It is safe to ignore this err or message. DIMM SPD dat[...]
-
Page 21
Sun Blade X6440 Server Module Product Notes 19 Hard disk information is unknown When running the Pc-Check hard disk diagnostics, the har d disk information, hard disk firmwar e, and serial number are listed as unknown. Serial port test fails The Pc-Check serial port test fails because Pc-Check does not support the RJ-45 serial port connector . SunV[...]
-
Page 22
20 Sun Blade X6440 Server Module Product Notes • November 2009 ■ “Only 8 of 16 CPU cores being r eported” on page 22 ■ “Post OS driver update script fails to run” on page 23 ■ “SLES OS driver installation takes a long time to complete” on page 23 ■ “NIC drivers are not supported by SLES1 1 OS” on page 23 ■ “SLES 9 SP4 [...]
-
Page 23
Sun Blade X6440 Server Module Product Notes 21 This issue is being investigated. Linux Issues The following issue applies to Sun Blade X6440 server modules running the supported Red Hat Enterprise Linux (RHEL) or SUSE Linux Enterprise Server (SLES) operating systems. USB device err ors reported in Red Hat 5.1 The following error is generated when a[...]
-
Page 24
22 Sun Blade X6440 Server Module Product Notes • November 2009 3. Insert the PEM in either slot and press the Attn button. The PEM is ready to use when the OK LED turns solid gr een. PCI BIOS error message might appear The following error message might appear when booting or running the dmesg command in RHEL 5.1: PCI: BIOS Bug: MCFG area at e0000[...]
-
Page 25
Sun Blade X6440 Server Module Product Notes 23 W orkaround: Install and boot from the largesmp kernel version, which can be found in the installation media. Post OS driver update script fails to run The following error message might display when running the post OS driver ( install.sh ) update script: bash ./install.sh: /bin/sh: bad interpreter: Pe[...]
-
Page 26
24 Sun Blade X6440 Server Module Product Notes • November 2009 W orkaround: This issue can be resolved by following these steps: 1. T emporarily limit the memory to less than 4 GB. This can be accomplished by physically removing RAM to reduce it to less than 4 GB. Alternately , you can use a boot parameter to limit the memory that is used by SLES[...]
-
Page 27
Sun Blade X6440 Server Module Product Notes 25 2. Reboot the system for the changes to take effect. 3. Run Windows Autorun to install drivers. Y ellow question mark might appear in W indows Device Manager A yellow question mark might appear in the W indows Device Manager , denoting that drivers are not installed for the following devices: ■ Sun B[...]
-
Page 28
26 Sun Blade X6440 Server Module Product Notes • November 2009 LSI RAID Expansion Module (REM) Issues This section contains the following LSI RAID REM issues: ■ “Extra hard disk drive space requir ed when upgrading to a Mirrored RAID configuration” on page 26 ■ “Upgrade path for data merging” on page 26 Extra har d disk drive space r [...]