Superior CFST-CMP manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Superior CFST-CMP, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Superior CFST-CMP one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Superior CFST-CMP. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Superior CFST-CMP should contain:
- informations concerning technical data of Superior CFST-CMP
- name of the manufacturer and a year of construction of the Superior CFST-CMP item
- rules of operation, control and maintenance of the Superior CFST-CMP item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Superior CFST-CMP alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Superior CFST-CMP, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Superior service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Superior CFST-CMP.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Superior CFST-CMP item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 1 Unvented Decorative Gas Fireplaces P/N 903589 REV. E 02/2004 CFST -CMN CFPF-CMN CFST -CMP CFPF-CMP MODELS ST ANDARD SERIES INST ALLA TION INSTRUCTIONS FOR USE ONLY WITH DECORATIVE TYPE UNVENTED ROOM HEATERS. DO NOT BUILD A WOOD FIRE. FOR YOUR SAFETY: Do not store or use gasoline or other flammable v[...]

  • Page 2

    NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 2 GENERAL INFORMATION The CFST and CFPF Series Unvented Room Heaters covered in this manual feature ceramic fiber split logs which glow realistically when the heater is operating. These heaters have a standing pilot and are manually controlled through the use of a milli- volt gas valve. A spark igniti[...]

  • Page 3

    NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 3 WARNING: FAILURE TO COMPLY WITH THE INSTALLATION AND OPERATING IN- STRUCTIONS PROVIDED IN THIS DOCU- MENT WILL RESULT IN AN IMPROPERLY INSTALLED AND OPERATING UNVENTED ROOM HEATER, VOIDING ITS WAR- RANTY. ANY CHANGE TO THIS HEATER AND/OR ITS OPERATING CONTROLS IS DANGEROUS. IMPROPER INSTALLA- TION O[...]

  • Page 4

    NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 4 Example: CFST/PF heater 34,000 BTU/Hr Gas appliance #1 32,000 BTU/Hr (water heater) Total = 66,000 BTU/Hr * Do not include direct-vent gas appliances. Direct-vent is sealed combustion and draws combustion air from the outdoors. 4 . Compare the maximum BTU/Hr the space can support with the actual amo[...]

  • Page 5

    NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 5 Minimum clearance to combustibles are: Appliance: side and back - 0" floor - 0" adjacent wall - 6" ceiling - 41 ⁵⁄₈ ” (1210 mm) Figure 1 A hearth extension is not required with this appliance. If a hearth extension is used, do not block the lower control compartment door. Any [...]

  • Page 6

    NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 6 CFST FRAMING SPECIFICATIONS CFST APPLIANCE SPECIFICATIONS A 22 ³⁄₄ " (578 mm)* B 43" (1092 mm) Min. C 43" (1092 mm) Min. Framing Dimensions Figure 3 Figure 4 Figure 5 C A B Gas Line 2 x 4 Wall Framing T op View * ¹⁄₂ " (13mm) Required Air Space Clearance Drywall * Gas L[...]

  • Page 7

    NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 7 Figure 6 Figure 7 Figure 8 C A B Gas Line CFPF FRAMING SPECIFICATIONS CFPF APPLIANCE SPECIFICATIONS Gas Line Energy Wall 2 x 4 Outside Wall Drywall Dr ywall * Bracket Bracket Framing T op View * ¹⁄₂ " (13mm) Required Air Space Clearance A 22 ³⁄₄ " (578 mm)* B 40 ¹⁄₈ " ([...]

  • Page 8

    NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 8 Step 2 . Route a ¹⁄₂ " (13 mm) gas line along the left or right side framing ( Figure 9 ). All appliances have a 3" long ³⁄₈ " NPT nipple installed at the valve. To quickly and easily complete the gas line routing, use the gas flex line kit, Model GFLV. Figure 11 The gas con[...]

  • Page 9

    NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 9 Step 7. Installing the Optional Remote Wall Switch – The standard millivolt system comes from the factory wired as shown in Figure 12 . Select a convenient location for the remote wall switch and connect the wiring to the appliance ( Figure 13 ). CAUTION: DO NOT CONNECT THE OPTIONAL REMOTE SWITCH [...]

  • Page 10

    NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 10 Assembling the Logs WARNING: DO NOT ADD EXTRA LOGS OR ORNAMENTS SUCH AS PINE CONES, VERMICULITE OR ROCK WOOL. USING THESE ADDED ITEMS CAN CAUSE SOOTING. Figure 15 Step 9. The heater includes a set of ceramic fiber logs. The logs are assembled as shown in Figure 15 . Handle these logs with great car[...]

  • Page 11

    NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 11 The installation of the logs and twigs, should be complete and resemble Figures 15, 16 and 19 . After setting the logs and rockwool into posi- tion as described above, ensure the logs are properly and firmly situated. The heater will not function as intended if the logs are not correctly positioned[...]

  • Page 12

    NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 12 The appliances covered in this manual are heater rated and produce a great deal of heat. Decorative brass trim pieces and hoods may tarnish because of their proximity to the heater opening and front face. Tarnishing of these pieces is normal, unavoidable and should be expected. Forced Air Kit The F[...]

  • Page 13

    NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 13 Gas Flex Line with Valve A gas flex line kit is available to aid in attaching the appliance to the gas supply. This kit can only be used where local codes permit. The kit includes a ¹⁄₂ " NPT to ³⁄₈ " flare in line shut-off valve, a 12" flex line ³⁄₈ " female flar[...]

  • Page 14

    NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 14 ACCESSORIES AND COMPONENTS Forced Air Kit FAB-1100 Remote Control Kit RCK Rocker Switch Kit RS Wall Switch Kit WSK Gas Flex Line Kit GFLV Decorative Volcanic Stone DVS 4-Piece Decorative Arch Frame Kit -Main Panel DAT-6-4 -End Panel DAET-6-4 1-Piece Decorative Arch Frame Kit -Main Panel DAT-6-1 -En[...]

  • Page 15

    NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 15 OPERATING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTING LIGHTING INSTRUCTIONS 1. Stop! Read the safety information above. 2. Make sure manual shut-off valve is fully open. 3. Locate gas control knob and piezo. 4. Depress control knob in and turn clockwise to the “OFF” position ( Figure 23 )[...]

  • Page 16

    NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 16 Note: Knob cannot be turned from “PILOT” to “OFF” unless the knob is pushed in slightly. Do not force. Figure 23 Pilot Location Figure 24 Figure 25 Turn Control Knob to “OFF” Position Turn Control Knob to “PILOT” Position EA TPTH TP TH P I L O T H I L O W P I L O T O N it O F F EA T[...]

  • Page 17

    NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 17 CFST REPLACEMENT PARTS LIST CFST GAS CONTROLS — MILLIVOLT CFST-CMN CFST-CMP No. Description Part No. Qty. Part No. Qty. 1. Gas Fireplace Assembly 123071 1 123072 1 2. Bar, Louver (Black) 104951 8 104951 8 3. Hood (Black), Clean Face 108971 2 108971 2 4. Screw 000861 6 000861 6 5. Replacement Glas[...]

  • Page 18

    NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 18 REPLACEMENT PARTS – CFST 8 20 9 21 22 23 a. b. c. d. f. g. e. 3 2 1 7 6 2 11 4 5 10[...]

  • Page 19

    NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 19 CFPF REPLACEMENT PARTS LIST CFPF GAS CONTROLS — MILLIVOLT CFPF-CMN CFPF-CMP No. Description Part No. Qty. Part No. Qty. 1. Gas Fireplace Assembly 123073 1 123074 1 2. Bar, Louver (Black) - Main Panel 104951 8 104951 8 3. Bar, Louver (Black) - End Panel 104955 4 104955 4 4. Hood (Black), Clean Fac[...]

  • Page 20

    NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 20 REPLACEMENT PARTS – CFPF 11 20 12 21 22 23 13 4 2 1 10 14 7 6 2 5 3 3 9 a. b. c. d. e. 8 f. g.[...]

  • Page 21

    NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 21 1. When igniter button is pressed, there is no spark at ODS/pilot. 2. Heater produces unwanted odors. 3. Heater shuts off in use (ODS operates). 4. Gas odor even when control knob is in “OFF” position. 5. When igniter button is pressed, there is spark at ODS/pilot, but no ignition. 6. ODS/pilot[...]

  • Page 22

    NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 22[...]

  • Page 23

    NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 23[...]

  • Page 24

    NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 24 Printed in U.S.A. © 1997 by SFC P/N 903589 REV. E 02/2004 Catalytic Gas Fireplace Manufacturer's Limited W arranty 10 Y ears THE WARRANTY The manufacturer warrants the components of this Catalytic Gas Fireplace manufactured by SFC, INC. (hereinafter, SFC) to be free from defects in materials [...]