Superior VFGL-28VSN-4 SERIES manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Superior VFGL-28VSN-4 SERIES, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Superior VFGL-28VSN-4 SERIES one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Superior VFGL-28VSN-4 SERIES. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Superior VFGL-28VSN-4 SERIES should contain:
- informations concerning technical data of Superior VFGL-28VSN-4 SERIES
- name of the manufacturer and a year of construction of the Superior VFGL-28VSN-4 SERIES item
- rules of operation, control and maintenance of the Superior VFGL-28VSN-4 SERIES item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Superior VFGL-28VSN-4 SERIES alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Superior VFGL-28VSN-4 SERIES, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Superior service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Superior VFGL-28VSN-4 SERIES.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Superior VFGL-28VSN-4 SERIES item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 1 Unvented Gas Log Room Heaters P/N 903623 REV. M 12/2007 MODELS ST ANDARD SERIES FOR USE ONLY WITH DECORATIVE TYPE UNVENTED ROOM HEATERS. FOR YOUR SAFETY: Do not store or use gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance. FOR YOUR SAFETY: What to do if y[...]

  • Page 2

    NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 2 TABLE OF CONTENTS General Information ......................... page 2 Inventory ......................................... page 2 Tools Required ................................ page 2 Important Safety Information .......... page 2 Codes .............................................. page 3 Combusti[...]

  • Page 3

    NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 3 • The installation must conform with local codes or, in the absence of local codes with the National Fuel Gas Code, ANSI Z223.1. • The heater and its individual shut-off valve must be disconnected from the gas supply piping system while performing any tests of the gas supply piping system at pre[...]

  • Page 4

    NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 4 The space in the previous example is a confined space because the actual BTU/Hr used is more than the maximum BTU/Hr the space can sup- port. You must provide additional fresh air. Your options are: a. Rework equations adding the space of ad- joining room(s). If the extra volume provides an unconfin[...]

  • Page 5

    NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 5 Noncombustible Material Requirements with No Mantel Installed (A) Noncombustible Material Measurement Requirements for Safe Installation 12" or more Adjustable canopy not required. 8" minimum to 12" Install adjustable canopy, P/N 053752 ( Figure 3 ). Less than 8" Extend noncombus[...]

  • Page 6

    NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 6 To avoid any movement of the heater during operation, attach the grate to the floor of the fireplace or firebox using the screws provided. Slots along the back flange of the log set are provided. After centering the grate correctly, mark the positions of the bottom of the slots on the fireplace/fire[...]

  • Page 7

    NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 7 Union Regulator Fireplace or Firebox Wall Wal l Shut-Off Key 3" Manual Shut-Off Valve Fireplace or Firebox Wall Sediment Tr a p Down Each heater includes a unitized set of ceramic fiber logs. The heater and logs are assembled as shown in Figure 11 . Handle these logs with great care. The logs c[...]

  • Page 8

    NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 8 In normal operation, at full rate, after 15 min- utes the following flame appearance should be observed: CAUTION: YOU MUST KEEP CONTROL AR- EAS, BURNERS AND CIRCULATING AIR PAS- SAGEWAYS OF FIREPLACE CLEAN. INSPECT THESE AREAS OF FIREPLACE BEFORE EACH USE. HAVE FIREPLACE AND CHIMNEY (IF APPLICABLE) [...]

  • Page 9

    NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 9 ACCESSORIES Decorative Volcanic Stone P/N 110791 FDVS Black P/N 053752 AC - BLK Adjustable Canopy Damper Clamp P/N 110701 DCK Thermostat P/N 064248 WTK Wall Switch Kit P/N 064035 FWSK OPTIONAL EQUIPMENT All options are available in kit form, are easy to install and are packaged complete with all re-[...]

  • Page 10

    NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 10 UNVENTED GAS LOG ROOM HEATER SPECIFICATION CHART Model No. Valve Operation BTU/hr Input Gas Type * Manual control models are also design certified for use as vented gas log sets. UNVENTED GAS LOG ROOM HEATER TECHNICAL CHART BTU/HR Regulator Gas Inlet Valve Model No. High Gas Type Ignition Pres. Set[...]

  • Page 11

    NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 11 1. When igniter button is pressed, there is no spark at ODS/pilot. 2. Heater produces unwanted odors. 3. Heater shuts off in use (ODS operates). 4. Gas odor even when control knob is in “OFF” position. 5. When igniter button is pressed, there is spark at ODS/pilot, but no ignition. 6. ODS/pilot[...]

  • Page 12

    NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 12 OPERATING INSTRUCTIONS — MANUAL CONTROL MODELS FOR YOUR SAFETY READ BEFORE LIGHTING LIGHTING INSTRUCTIONS 1. Stop! Read the safety information above. 2. Make sure manual shut-off valve is fully open. 3. Refer to Figure 15 to locate gas control knob and piezo. 4. Depress control knob in and turn c[...]

  • Page 13

    NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 13 Figure 16 Figure 15 Control Knob Locations Pilot Location Turn Control Knob to “OFF” Position (Manual) Turn Control Knob to “IGN” Position (Manual) Figure 18 Figure 17 Pilot O F F I G N L O W H I O F F I G N L O W H I Millivolt Model Piezo Gas Control Knob Flame Adjustment Knob[...]

  • Page 14

    NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 14 OPERATING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTING LIGHTING INSTRUCTIONS 1. Stop! Read the safety information above. 2. Make sure manual shut-off valve is fully open. 3. Locate gas control knob and piezo. 4. Depress control knob in and turn clockwise to the “OFF” position ( Figure 19 )[...]

  • Page 15

    NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 15 Note: Knob cannot be turned from “PILOT” to “OFF” unless the knob is pushed in slightly. Do not force. Figure 19 Pilot Location Figure 20 Pilot Figure 21 Turn Control Knob to “OFF” Position Turn Control Knob to “PILOT” Position EA TPTH TP TH P I L O T H I L O W P I L O T O N it O F [...]

  • Page 16

    NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 16 REPLACEMENT PARTS LIST 18N/18P 24N/24P 28N/28P No. Description Part No. Part No. Part No. 1. Valve - Manual (Natural) 110331 110331 110331 Valve - Manual (Propane, L.P.G.) 110331 110331 110331 2. Valve, Millivolt (Natural) 903489 903489 903489 Valve, Millivolt (Propane, L.P.G.) 901917 901917 901917[...]

  • Page 17

    NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 17 REPLACEMENT PARTS 1 2 5 9 10 13 14 12 8 7 6 11 4 3[...]

  • Page 18

    NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 18 NOTE: THIS PAGE INTENTIONALLY LEFT BLANK.[...]

  • Page 19

    NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 19 NOTE: THIS PAGE INTENTIONALLY LEFT BLANK.[...]

  • Page 20

    The manufacturer reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products. Consult your local distributor for fireplace code information. Printed in U.S.A. © 1997 by Lennox Hearth Products P/N 903623 REV. M 12/2007 LHP 1110 West Taft Avenue Oran[...]