Go to page of
Similar user manuals
-
Server
Supermicro SuperServer 6028TP-HC0TR
140 pages -
Server
Supermicro SBA-7142G-T4
80 pages -
Server
Supermicro 2015TA-HTRF
85 pages -
Server
Supermicro SuperServer 1028R-TDW
133 pages -
Server
Supermicro SuperServer 1028R-WTR
126 pages -
Server
Supermicro SuperServer 6028R-TRT
126 pages -
Server
Supermicro SuperServer 2028TP-HTR
141 pages -
Server
Supermicro 6025B-UR
122 pages 1.31 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Supermicro SuperServer 6028R-WTRT, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Supermicro SuperServer 6028R-WTRT one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Supermicro SuperServer 6028R-WTRT. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Supermicro SuperServer 6028R-WTRT should contain:
- informations concerning technical data of Supermicro SuperServer 6028R-WTRT
- name of the manufacturer and a year of construction of the Supermicro SuperServer 6028R-WTRT item
- rules of operation, control and maintenance of the Supermicro SuperServer 6028R-WTRT item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Supermicro SuperServer 6028R-WTRT alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Supermicro SuperServer 6028R-WTRT, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Supermicro service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Supermicro SuperServer 6028R-WTRT.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Supermicro SuperServer 6028R-WTRT item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
SUPERSER VER 6028R-WTR 6028R-WTR T ® S UPER USER’S MANUAL Revision 1.0[...]
-
Page 2
The information in this User ’s Manual has been carefully reviewed and is believed to be accurate. The vendor assumes no responsibility for any inaccuracies that may be contained in this document, makes no commitment to update or to keep current the information in this manual, or to notify any person or organization of the updates. Please Note: F[...]
-
Page 3
iii Preface Preface About This Manual This manual is written for professional system integrators and PC technicians. It provides information for the installation and use of the SuperServer 6028R-WTR(T). Installation and maintainance should be performed by experienced technicians only . The SuperServer 6028R-WTR(T) is a high-end server based on the [...]
-
Page 4
SUPERSERVER 6028R-WTR(T) USER'S MANUAL iv Chapter 5: Advanced Serverboard Setup Chapter 5 provides detailed information on the X10DRW -i(T) serverboard, including the locations and functions of connections, headers and jumpers. Refer to this chapter when adding or removing processors or main memory and when recon fi guring the serverboard. Ch[...]
-
Page 5
Notes Preface v[...]
-
Page 6
vi T able of Contents Chapter 1 Introduction 1-1 Overview ......................................................................................................... 1-1 1-2 Serverboard Features ..................................................................................... 1-2 Processors ........................................................[...]
-
Page 7
vii Chapter 3 System Interface 3-1 Overview ......................................................................................................... 3-1 3-2 Control Panel Buttons ..................................................................................... 3-1 Reset ..........................................................................[...]
-
Page 8
viii SUPERSERVER 6028R-WTR(T) USER'S MANUAL 5-4 Installing the Processor and Heatsink ............................................................ 5-5 Installing an LGA 201 1 Processor ................................................................... 5-5 Installing a Passive CPU Heatsink ......................................................[...]
-
Page 9
ix T able of Contents Chapter 7 BIOS 7-1 Introduction ...................................................................................................... 7-1 Starting BIOS Setup Utility .............................................................................. 7-1 How T o Change the Con fi guration Data .....................................[...]
-
Page 10
SUPERSERVER 6028R-WTR(T) USER'S MANUAL x Notes[...]
-
Page 11
Chapter 1 Introduction 1-1 Overview The SuperServer 6028R-WTR(T) is a high-end server comprised of two main subsystems: the SC815TS-R740WBP 2U chassis and the X10DR W-i(T) dual processor serverboard. Please refer to our web site for information on operating systems that have been certi fi ed for use with the system ( www .supermicro.com ). In addi[...]
-
Page 12
1-2 SUPERSERVER 6028R-WTR(T) USER'S MANUAL 1-2 Serverboard Features The SuperServer 6028R-WTR(T) is built around the X10DRW -i(T), a dual processor serverboard based on the Intel PCH-C612 chipset and designed to provide maximum performance. Below are the main features of the X10DRW -i(T),. (See Figure 1-1 for a block diagram of the chipset.) P[...]
-
Page 13
1-3 Chapter 1: Introduction Rear I/O Ports Ports on the I/O backplane includes a VGA port, four USB 2.0 ports, two gigabit (6028R-WTR) or 10-gigabit (6028R-WTRT) Ethernet ports and one IPMI port. A UID (Unit Identi fi er) button and LED are also located beside the VGA port. 1-3 Server Chassis Features The SC815TS-R740WBP is an A TX form factor cha[...]
-
Page 14
1-4 SUPERSERVER 6028R-WTR(T) USER'S MANUAL 1-6 Advanced Power Management Intel® Intelligent Power Node Manager (IPNM) The Intel ® Intelligent Power Node Manager (IPNM) provides your system with real-time thermal control and power management for maximum energy ef fi ciency . Although IPNM Speci fi cation V ersion 2.0 is supported by the BMC[...]
-
Page 15
1-5 Chapter 1: Introduction Figure 1-1. Intel PCH-C612 Chipset: System Block Diagram Note: This is a general block diagram. Please see Chapter 5 for details. x16 P1 P1 P0 P0 CPU FRONT CPU DMI PE1 PE2 PE3 PE3 PE1 PE2 DDR4 DIMM 4,5 port 0,1 REAR DDR4 DIMM #1 #2 DDR4 DIMM A G x16 RIGHT SLOT SXB2 PCIE 3.0 x16 x16 RJ45 JLAN1 UL1 RJ45 JLAN2 PHY RTL8211E [...]
-
Page 16
1-6 SUPERSERVER 6028R-WTR(T) USER'S MANUAL 1-4 Contacting Supermicro Headquarters Address: Super Micro Computer , Inc. 980 Rock Ave. San Jose, CA 95131 U.S.A. T el: +1 (408) 503-8000 Fax: +1 (408) 503-8008 Email: marketing@supermicro.com (General Information) support@supermicro.com (T echnical Support) Web Site: www .supermicro.com Europe Addr[...]
-
Page 17
Chapter 2: Server Installation 2-1 Chapter 2 Server Installation 2-1 Overview This chapter provides a quick setup checklist to get your SuperServer 6028R-WTR(T) up and running. Following these steps in the order given should enable you to have the system operational within a minimum amount of time. This quick setup assumes that your system has come[...]
-
Page 18
2-2 SUPERSERVER 6027R-73DARF User's Manual Choosing a Setup Location • Leave enough clearance in front of the rack to enable you to open the front door completely (~25 inches) and approximately 30 inches of clearance in the back of the rack to allow for suf fi cient air fl ow and ease in servicing. • This product is for installation only[...]
-
Page 19
Chapter 2: Server Installation 2-3 Rack Mounting Considerations Warning! T o prevent bodily injury when mounting or servicing this unit in a rack, you must take special precautions to ensure that the system remains stable. The following guidelines are provided to ensure your safety: • This unit should be mounted at the bottom of the rack if it is[...]
-
Page 20
2-4 SUPERSERVER 6027R-73DARF User's Manual 2-4 Installing the System into a Rack This section provides information on installing the SC815 chassis into a rack unit with the quick-release rails provided. There are a variety of rack units on the market, which may mean the assembly procedure will differ slightly . Y ou should also refer to the in[...]
-
Page 21
Chapter 2: Server Installation 2-5 Figure 2-1: Separating the Rack Rails Separating the Inner and Outer Rails 1. Locate the rail assembly in the chassis packaging. 2. Extend the rail assembly by pulling it outward. 3. Press the quick-release tab. 4. Separate the inner rail extension from the outer rail assembly . 1 1 1 2 1 4 1 3 Rail Assembly Exten[...]
-
Page 22
2-6 SUPERSERVER 6027R-73DARF User's Manual Installing the Chassis into a Rack 1. Extend the outer rails as illustrated above. 2. Align the inner rails of the chassis with the outer rails on the rack. 3. Slide the inner rails into the outer rails, keeping the pressure even on both sides. When the chassis has been pushed completely into the rack[...]
-
Page 23
Chapter 3: System Interface 3-1 Chapter 3 System Interface 3-1 Overview There are several LEDs on the control panel as well as others on the drive carriers to keep you constantly informed of the overall status of the system and the activity and health of speci fi c components. There are also two buttons on the chassis control panel. 3-2 Control Pa[...]
-
Page 24
SUPERSERVER 6027R-73DARF User's Manual 3-2 1 3-3 Control Panel LEDs The control panel located on the front of the chassis has several LEDs. These LEDs provide you with critical information related to different parts of the system. This section explains what each LED indicates when illuminated and any corrective action you may need to take. Pow[...]
-
Page 25
Chapter 3: System Interface 3-3 2 NIC2 Indicates network activity on the LAN2 port when fl ashing. HDD On the SuperServer 6028R-WTR(T), this LED indicates hard drive and/or DVD-ROM drive activity when fl ashing. Power Indicates power is being supplied to the system's power supply units. This LED should normally be illuminated when the system[...]
-
Page 26
SUPERSERVER 6027R-73DARF User's Manual 3-4 Notes[...]
-
Page 27
4-1 Chapter 4: W arning Statements for AC Systems Chapter 4 Standardized W arning Statements for AC Systems 4-1 About Standardized W arning Statements The following statements are industry standard warnings, provided to warn the user of situations which have the potential for bodily injury . Should you have questions or experience difficulty , cont[...]
-
Page 28
4-2 SUPERSERVER 6028R-WTR(T) USER'S MANUAL W arnung WICHTIGE SICHERHEITSHINWEISE Dieses W arnsymbol bedeutet Gefahr . Sie be fi nden sich in einer Situation, die zu V erletzungen führen kann. Machen Sie sich vor der Arbeit mit Geräten mit den Gefahren elektrischer Schaltungen und den üblichen V erfahren zur V orbeugung vor Unfällen vertra[...]
-
Page 29
4-3 W arning Statements for AC Systems 안전을 위한 주의사항 경고! 이 경고 기호는 위험이 있음을 알려 줍니다. 작업자의 신체에 부상을 야기 할 수 있는 상태에 있게 됩니다. 모든 장비에 대한 작업을 수행하기 전에 전기회로와 관련된 위험요소들을 확인하시고 사전에 사고[...]
-
Page 30
4-4 SUPERSERVER 6028R-WTR(T) USER'S MANUAL Installation Instructions W arning! Read the installation instructions before connecting the system to the power source. 設置手順書 シ ス テ ム を 電源に接続す る 前に 、 設置手順書 を お読み下 さ い 。 警告 将此系统连接电源前,请先阅读安装说明。 警[...]
-
Page 31
4-5 Chapter 4: W arning Statements for AC Systems Circuit Breaker W arning! This product relies on the building's installation for short-circuit (overcurrent) protection. Ensure that the protective device is rated not greater than: 250 V , 20 A. サーキ ッ ト ・ ブ レ ーカー この 製 品 は 、 短絡 (過電流 ) 保護装置[...]
-
Page 32
4-6 SUPERSERVER 6028R-WTR(T) USER'S MANUAL Power Disconnection W arning W arning! The system must be disconnected from all sources of power and the power cord removed from the power supply module(s) before accessing the chassis interior to install or remove system components. 電源切断の警告 システムコン ポ ー ネン トの 取 ?[...]
-
Page 33
4-7 Chapter 4: W arning Statements for AC Systems W arnung Das System muss von allen Quellen der Energie und vom Netzanschlusskabel getrennt sein, das von den Spg.V ersorgungsteilmodulen entfernt wird, bevor es auf den Chassisinnenraum zurückgreift, um Systemsbestandteile anzubringen oder zu entfernen. ¡Advertencia! El sistema debe ser disconnect[...]
-
Page 34
4-8 SUPERSERVER 6028R-WTR(T) USER'S MANUAL Equipment Installation W arning! Only trained and quali fi ed personnel should be allowed to install, replace, or service this equipment. 機器の設置 ト レ ーニ ン グを受 け認定さ れた人だけが こ の装 置の 設 置、 交換、 また は サ ービス を 許 可 されて [...]
-
Page 35
4-9 Chapter 4: W arning Statements for AC Systems Restricted Area W arning! This unit is intended for installation in restricted access areas. A restricted access area can be accessed only through the use of a special tool, lock and key , or other means of security . (This warning does not apply to workstations). ア ク セ ス 制限区域 この[...]
-
Page 36
4-10 SUPERSERVER 6028R-WTR(T) USER'S MANUAL Battery Handling W arning! There is the danger of explosion if the battery is replaced incorrectly . Replace the battery only with the same or equivalent type recommended by the manufacturer . Dispose of used batteries according to the manufacturer's instructions 電池の取 り 扱い 電池?[...]
-
Page 37
4-1 1 Chapter 4: W arning Statements for AC Systems W arnung Bei Einsetzen einer falschen Batterie besteht Explosionsgefahr . Ersetzen Sie die Batterie nur durch den gleichen oder vom Hersteller empfohlenen Batterietyp. Entsorgen Sie die benutzten Batterien nach den Anweisungen des Herstellers. Attention Danger d'explosion si la pile n'es[...]
-
Page 38
4-12 SUPERSERVER 6028R-WTR(T) USER'S MANUAL Redundant Power Supplies W arning! This unit might have more than one power supply connection. All connections must be removed to de-energize the unit. 冗長電源装置 こ のユニ ッ ト は複数の 電源装置が接続 さ れ て い る 場合が あ り ま す 。 ユニ ッ ト の電 ?[...]
-
Page 39
4-13 Chapter 4: W arning Statements for AC Systems Backplane V oltage W arning! Hazardous voltage or energy is present on the backplane when the system is operating. Use caution when servicing. バ ッ ク プ レー ンの 電圧 シ ス テ ムの稼働 中は危 険な電 圧 ま たは電力が、 バ ッ ク プ レ ーン 上 にか かっ ?[...]
-
Page 40
4-14 SUPERSERVER 6028R-WTR(T) USER'S MANUAL Comply with Local and National Electrical Codes W arning! Installation of the equipment must comply with local and national electrical codes. 地方お よ び国の電気規格 に 準拠 機器の取 り 付け は そ の地方 お よ び 国の電気規格 に 準拠す る 必要が あ り ま[...]
-
Page 41
4-15 Chapter 4: W arning Statements for AC Systems Product Disposal W arning! Ultimate disposal of this product should be handled according to all national laws and regulations. 製品の廃棄 こ の製品 を廃棄処分 す る 場合 、 国の関 係す る 全 て の法律 ・ 条例に 従い処 理す る 必 要が あり ま す 。 警[...]
-
Page 42
4-16 SUPERSERVER 6028R-WTR(T) USER'S MANUAL W arnung Die Entsorgung dieses Produkts sollte gemäß allen Bestimmungen und Gesetzen des Landes erfolgen. ¡Advertencia! Al deshacerse por completo de este producto debe seguir todas las leyes y reglamentos nacionales. Attention La mise au rebut ou le recyclage de ce produit sont généralement sou[...]
-
Page 43
4-17 Chapter 4: W arning Statements for AC Systems ! הרהזא יקל ח תא םי רי סמ רשאכ שי . םידבוע ן יידע םיררווא מהו ןכתי , זראמהמ ררו ואמה קיחרהל ל ררו ואמה ךותב םיחתפהמ םינוש הדובע ילכו תועבצאה תא חוטב קחרמ ﻦﻜﻤﻤﻟﺍ ﻦﻣ ?[...]
-
Page 44
4-18 SUPERSERVER 6028R-WTR(T) USER'S MANUAL Power Cable and AC Adapter W arning! When installing the product, use the provided or designated connection cables, power cables and AC adaptors. Using any other cables and adaptors could cause a malfunction or a fi re. Electrical Appliance and Material Safety Law prohibits the use of UL or CSA -cer[...]
-
Page 45
4-19 Chapter 4: W arning Statements for AC Systems ¡Advertencia! Al instalar el producto, utilice los cables de conexión previstos o designados, los cables y adaptadores de CA. La utilización de otros cables y adaptadores podría ocasionar un mal funcionamiento o un incendio. Aparatos Eléctricos y la Ley de Seguridad del Material prohíbe el us[...]
-
Page 46
4-20 SUPERSERVER 6028R-WTR(T) USER'S MANUAL W aarschuwing Bij het installeren van het product, gebruik de meegeleverde of aangewezen kabels, stroomkabels en adapters. Het gebruik van andere kabels en adapters kan leiden tot een storing of een brand. Elektrisch apparaat en veiligheidsinformatiebladen wet verbiedt het gebruik van UL of CSA gecer[...]
-
Page 47
Chapter 5: Advanced Serverboard Setup 5-1 Chapter 5 Advanced Serverboard Setup This chapter covers the steps required to connect the data and power cables and install add-on cards. All serverboard jumpers and connections are also described. A layout and quick reference chart are included in this chapter for your reference. Remember to completely cl[...]
-
Page 48
5-2 SUPERSERVER 6028R-WTR(T) USER'S MANUAL 5-2 Connecting Cables Now that the serverboard is installed, the next step is to connect the cables to the board. These include the data cables for the peripherals and control panel and the power cables. Connecting Data Cables The cables used to transfer data from the peripheral devices have been care[...]
-
Page 49
Chapter 5: Advanced Serverboard Setup 5-3 Figure 5-1. Control Panel Header Pins Po we r Butto n OH/Fan Fail/ PWR Fail LED) 1 NIC1 Link LED Re s e t Butto n 2 Po we r Fail LED HDD LED FP PWRLED Rese t PWR 3.3 V UID LED Blue LED Cathode Gr ound Gr ound 19 20 3.3V X Gr ound NMI X NIC2 Link LED NIC2 Activity LED NIC1 Activity LED Connecting the Control[...]
-
Page 50
5-4 SUPERSERVER 6028R-WTR(T) USER'S MANUAL 5-3 Rear I/O Ports The I/O ports are in conformance with the PC 99 speci fi cation. See Figure 5-2 below for the locations of the various I/O ports. Figure 5-2. Rear I/O Ports Rear I/O Ports 1 VGA Port 2 USB 3.0 Port 0 3 USB 3.0 Port 1 4 IPMI Dedicated LAN Port 5 USB 3.0 Port 2 6 USB 3.0 Port 3 7 Gig[...]
-
Page 51
Chapter 5: Advanced Serverboard Setup 5-5 1. There are two levers on the LGA201 1 socket. First press and release the load lever labeled 'Open 1st'. Installing an LGA 201 1 Processor 5-4 Installing the Processor and Heatsink Caution: When handling the processor package, avoid placing direct pressure on the label area of the fan. Notes: ?[...]
-
Page 52
5-6 SUPERSERVER 6028R-WTR(T) USER'S MANUAL 3. With the lever labeled 'Close 1 st' f u l l y r e tr a c t e d , g e n t l y p u s h d o w n on t he ' Op en 1st ' leve r to op en the load plate. Lif t the load plate t o o p e n i t co m p l e t e l y . W ARNING! W ARNING! Gently push down to pop the load plate open. OPEN 1st [...]
-
Page 53
Chapter 5: Advanced Serverboard Setup 5-7 Caution: Y ou can only install the CPU to the socket in one direction. Make sure that the CPU is properly inserted into the socket before closing the load plate. If it doesn't close properly , do not force it as it may damage your CPU. Instead, open the load plate again and double-check that the CPU is[...]
-
Page 54
5-8 SUPERSERVER 6028R-WTR(T) USER'S MANUAL Installing a Passive CPU Heatsink 1. Do not apply any thermal grease to the two heatsinks or the CPU die -- the required amount has already been applied. 2. Place the heatsink on top of the CPU so that the four mounting holes are aligned with those on the Motherboard's and the Heatsink Bracket un[...]
-
Page 55
Chapter 5: Advanced Serverboard Setup 5-9 Removing the Heatsink W arning: We do not recommend that the CPU or the heatsink be removed. However , if you do need to uninstall the heatsink, please follow the instructions below to uninstall the heatsink to prevent damage done to the CPU or the CPU socket. 1. Unscrew the heatsink screws from the motherb[...]
-
Page 56
5-10 SUPERSERVER 6028R-WTR(T) USER'S MANUAL 5-5 Installing Memory Caution! Exercise extreme care when installing or removing DIMM modules to prevent any possible damage. Memory Support The X10DRW -i(T) supports up to 1024 GB of ECC registered (RDIMM) or ECC Load Reduced (LRDIMM) DDR4 2133/1866/1600/1333 MHz speed, 1 GB, 2 GB, 4 GB, 8 GB, 16 GB[...]
-
Page 57
Chapter 5: Advanced Serverboard Setup 5-1 1 DIMM Module Population T able Follo w the t ables belo w when installing memor y . Processors and their Corresponding Memory Modules CPU# Corresponding DIMM Modules CPU 1 P1- DIMMA1 P1- DIMMB1 P1- DIMMC1 P1- DIMMD1 P1- DIMMA2 P1- DIMMB2 P1- DIMMC2 P1- DIMMD2 CPU2 P2- DIMME1 P2- DIMMF1 P2- DIMMG1 P2- DIMMH[...]
-
Page 58
5-12 SUPERSERVER 6028R-WTR(T) USER'S MANUAL Populating RDIMM/LRDIMM Memory Modules Intel E5-2600v3 Series Processor Memory Support T ype Ranks Per DIMM & Data Width DIMM Capacity (GB) Speed (MT/s), V oltage (V), Slot per Channel (SPC) and DIMM Per Channel (DPC) 1 Slot Per Channel 2 Slots Per Channel 1DPC 1DPC 2DPC 4Gb 8Gb 1.2V 1.2V 1.2V RD[...]
-
Page 59
Chapter 5: Advanced Serverboard Setup 5-13 5-6 Adding PCI Add-On Cards The 6028R-WTR(T) can accommodate up to six low-pro fi le add-on (expansion) cards. Installing an Add-on Card 1. Begin by removing the shield for the PCI slot you wish to populate. 2. Fully seat the card into the slot, pushing down with your thumbs evenly on both sides of the ca[...]
-
Page 60
5-14 SUPERSERVER 6028R-WTR(T) USER'S MANUAL Figure 5-5. X10DRW -i(T) Layout 5-7 Serverboard Details S-SGPIO I-SGPIO2 I-SGPIO1 JIPMB1 SAN MAC IPMI CODE JBA T1 JPWR1 S-SA T A1 S-SA T A0 S-SA T A3 S-SA T A2 I-SA T A1 I-SA T A0 I-SA T A3 I-SA T A2 I - S ATA 4 I - S ATA 5 BIOS LICENSE JPI2C1 JPWR2 JPWR3 JF1 JL1 JSTBY1 JTPM1 JVRM2 JVRM1 JPME2 JVR1 J[...]
-
Page 61
Chapter 5: Advanced Serverboard Setup 5-15 X10DRW -i(T) Jumpers Jumper Description Default Setting JBT1 Clear CMOS See Chapter 3 JI 2 C1/JI 2 C2 SMB to PCI-E slots Pins 2-3 (Disabled) JPB1 BMC Enable Pins 1-2 (Enabled) JPG1 VGA Enable Pins 1-2 (Enabled) JPL1 GLAN1/GLAN2 Enable (X10DRW -i) 10G_LAN1/10G_LAN2 Enable (X10DRW -iT) Pins 1-2 (Enabled) JPM[...]
-
Page 62
5-16 SUPERSERVER 6028R-WTR(T) USER'S MANUAL Connectors Description S-SGPIO Seria_Link General-Purpose (SGPIO) I/O header for S-SA T A connections 0-3 SP1 Internal speaker/buzzer SXB1A SMC-proprietary SPEC slot (Left) (See Note 2 below .) SXB1B (CPU1/CPU2) PCI-E 3.0x16 + x16 add-on card slot (Left) (Note 2 below .) SXB1C SMC-proprietary SPEC sl[...]
-
Page 63
Chapter 5: Advanced Serverboard Setup 5-17 5-8 Connector De fi nitions Power Connectors A 24-pin main power supply connector (JPWR1), and two 8-pin CPU power connectors (JPWR2/JPWR3) are located on the serverboard. These power connectors meet the SSI EPS 12V speci fi cation and must be connected to your power supply to provide adequate power to t[...]
-
Page 64
5-18 SUPERSERVER 6028R-WTR(T) USER'S MANUAL NIC1/NIC2 LED Indicators The NIC (Network Interface Controller) LED connection for LAN Port 1 is located on pins 1 1 and 12 of JF1, and for LAN Port 2 is on pins 9 and 10. Attach the NIC LED cables here to display network activity . Refer to the table on the right for pin de fi nitions. HDD/UID LED [...]
-
Page 65
Chapter 5: Advanced Serverboard Setup 5-19 Power LED Th e Power LED c o nne ct io n is lo c ated on pins 1 5 and 1 6 of JF 1 . Ref er t o t he ta ble o n th e ri ght f or pi n de fi nit ions. Power LED Pin De fi nitions (JF1) Pin# De fi nition 15 3.3V 16 PWR LED NMI Button The non-maskable interrupt button header is located on pins 19 and 20 of [...]
-
Page 66
5-20 SUPERSERVER 6028R-WTR(T) USER'S MANUAL Universal Serial Bus (USB) Four USB 3.0 ports (USB 0/1, USB 2/3) are located on the I/O backpanel. In addition, an internal USB header , located next to S-SA T A0, also provides two USB 3.0 connections (USB 4/5) for front panel support. (Cables are not included). See the tables on the right and below[...]
-
Page 67
Chapter 5: Advanced Serverboard Setup 5-21 Unit Identi fi er Switch/UID LED Indicator A Unit Identi fi er (UID) switch is located on the I/O backplane, and two UID LED indicators are located on the serverboard. The rear UID LED (LED1) is located next to the UID switch. The front UID LED is located on pins 7 & 8 on the front control panel (JF1[...]
-
Page 68
5-22 SUPERSERVER 6028R-WTR(T) USER'S MANUAL S-SGPIO and I-SGPIO 1/2 Headers Three SGPIO (Serial Link General Purpose Input/Output) headers are located on the serverboard. I-SGPIO 1 supports I-SA T A 0-3, and I-SGPIO 2 supports I-SA T A 4/5. S-SGPIO is used for S-SA T A 0-3. See the table on the right for pin de fi nitions. Fan Header Pin De ?[...]
-
Page 69
Chapter 5: Advanced Serverboard Setup 5-23 5-9 Jumper Settings Explanation of Jumpers T o modify the operation of the serverboard, jumpers can be used to choose between optional settings. Jumpers create shorts between two pins to change the function of the connector . Pin 1 is identi fi ed with a square solder pad on the printed circuit board. See[...]
-
Page 70
5-24 SUPERSERVER 6028R-WTR(T) USER'S MANUAL W atch Dog Enable/Disable Jumper Settings (JWD1) Jumper Setting De fi nition Pins 1-2 Reset Pins 2-3 NMI Open Disabled VGA Enable/Disable Jumper Settings (JPG1) Jumper Setting De fi nition Pins 1-2 Enabled Pins 2-3 Disabled VGA Enable Jumper JPG1 allows the user to enable the onboard VGA connector [...]
-
Page 71
Chapter 5: Advanced Serverboard Setup 5-25 I 2 C to PCI-E Jumper Setting Jumper Setting De fi nition Pins 1-2 Enabled Pins 2-3 Disabled (Default) ME Mode Select Jumper Settings Jumper Setting De fi nition 1-2 Normal (Default) 2-3 Manufacture Mode I 2 C Bus to PCI-E Slots Use Jumpers JI 2 C1 and JI 2 C2 to connect the System Management Bus (I 2 C)[...]
-
Page 72
5-26 SUPERSERVER 6028R-WTR(T) USER'S MANUAL IPMI Dedicated LAN LEDs In addition to LAN 1/LAN 2, an IPMI- dedicated LAN is located on the I/O Backplane of the serverboard. The amb er LED o n th e ri ght in dic ate s ac tiv it y , w hil e the g re en LED o n th e lef t in dic ate s the s pee d of th e c onn ec ti on. S ee th e ta ble s at r igh [...]
-
Page 73
Chapter 5: Advanced Serverboard Setup 5-27 Onboard Power LED An Onboard Power LED is located at LED2 on the serverboard. When this LED is on, the system is on. Be sure to turn off the system and unplug the power cord before removing or installing components. See the tables at right for more information. Onboard PWR LED Indicator LED States LED Colo[...]
-
Page 74
5-28 SUPERSERVER 6028R-WTR(T) USER'S MANUAL Figure 5-6. Driver/T ool Installation Display Screen 5-12 Installing Software The Supermicro ftp site contains drivers and utilities for your system at ftp://ftp. supermicro.com . Some of these must be installed, such as the chipset driver . After accessing the ftp site, go into the CDR_Images direct[...]
-
Page 75
Chapter 5: Advanced Serverboard Setup 5-29 Note: Click the icons showing a hand writing on paper to view the readme fi les for each item. Click the computer icons to the right of these items to install each item (from top to the bottom) one at a time. After installing each item, you must re-boot the system before moving on to the next item on the [...]
-
Page 76
5-30 SUPERSERVER 6028R-WTR(T) USER'S MANUAL Figure 5-8. SuperDoctor 5 Interface Display Screen (Remote Control) Note: The SuperDoctor 5 program and User ’ s Manual can be downloaded from the Supermicro web site at http://www .supermicro.com/products/nfo/sms_sd5.cfm . For Linux, we recommend that you use the SuperDoctor II application instead[...]
-
Page 77
Chapter 5: Advanced Serverboard Setup 5-31 5-13 Serverboard Battery Caution : There is a danger of explosion if the onboard battery is installed upside down, which will reverse its polarites (see Figure 5-x). This battery must be replaced only with the same or an equivalent type recommended by the manufacturer (CR2032). Dispose of used batteries ac[...]
-
Page 78
5-32 SUPERSERVER 6028R-WTR(T) USER'S MANUAL Notes[...]
-
Page 79
Chapter 6: Advanced Chassis Setup 6-1 Chapter 6 Advanced Chassis Setup This chapter covers the steps required to install components and perform maintenance on the SC815TS-R740WBP chassis. For component installation, follow the steps in the order given to eliminate the most common problems encountered. If some steps are unnecessary , skip ahead to t[...]
-
Page 80
6-2 SUPERSERVER 6027R-73DARF User's Manual 6-2 Control Panel The control panel (located on the front of the chassis) must be connected to the JF1 connector on the serverboard to provide you with system status indications. A ribbon cable has bundled these wires together to simplify the connection. Connect the cable from JF1 on the serverboard t[...]
-
Page 81
Chapter 6: Advanced Chassis Setup 6-3 The fans in the system are redundant, hot-plug. Replacing System Fans Removing a Fan 1. Remove the chassis cover . 2. Press the tabs on the sides of the fan to unlock and remove the fan and its housing. The fan's power connections will automatically detach. 3. System power does not need to be shut down sin[...]
-
Page 82
6-4 SUPERSERVER 6027R-73DARF User's Manual 6-4 Drive Bay Installation/Removal Accessing the Drive Bays SAS/SA T A Drives: Y ou do not need to access the inside of the chassis or remove power to replace or swap SAS/SA T A drives. Proceed to the next step for instructions. Y ou must use standard 1" high, SAS/SA T A drives in the system. Not[...]
-
Page 83
Chapter 6: Advanced Chassis Setup 6-5 Figure 6-3. Removing a Drive Carrier Release Button Handle Caution: Regardless of how many hard drives are installed, all drive carriers must remain in the drive bays to maintain proper air fl ow . Use caution when working around the backplane. Do not touch the backplane with any metal objects and make sure no[...]
-
Page 84
6-6 SUPERSERVER 6027R-73DARF User's Manual DVD-ROM Installation (Optional) The top cover of the chassis must be opened to gain full access to the DVD-ROM drive bay . The SuperServer 6028R-WTR(T) accomodates only slim type DVD-ROM drives. Side mounting brackets are typically needed to mount a slim DVD-ROM drive in the server . Accessing the Ins[...]
-
Page 85
Chapter 6: Advanced Chassis Setup 6-7 6-5 Power Supply The SuperServer 6028R-WTR(T) has a 740 W att redundant power supply consisting of two power modules. Each power supply module has an auto-switching capability , which enables it to automatically sense and operate at a 100V - 240V input voltage. The SC815 chassis utilizes redundant, hot-plug pow[...]
-
Page 86
6-8 SUPERSERVER 6027R-73DARF User's Manual Notes[...]
-
Page 87
Chapter 7: BIOS 7-1 Chapter 7 BIOS 7-1 Introduction This chapter describes the AMI BIOS Setup utility for the X10DRW -i(T) It also provides the instructions on how to navigate the AMI BIOS Setup utility screens. The AMI ROM BIOS is stored in a Flash EEPROM and can be easily updated. Starting BIOS Setup Utility T o enter the AMI BIOS Setup utility s[...]
-
Page 88
7-2 SUPERSERVER 6028R-WTR(T) USER'S MANUAL How T o Change the Con fi guration Data The con fi guration data that determines the system parameters may be changed by entering the AMI BIOS Setup utility . This Setup utility can be accessed by pressing <Delete> at the appropriate time during system boot. Note : For AMI UEFI BIOS Recovery ,[...]
-
Page 89
Chapter 7: BIOS 7-3 Memory Information T otal Memory This displays the amount of memory that is available in the system. 7-3 Advanced Setup Con fi gurations Use the arrow keys to select Advanced and press <Enter> to access the following submenu items: Boot Feature Quiet Boot Use this feature to select the bootup screen display between PO[...]
-
Page 90
7-4 SUPERSERVER 6028R-WTR(T) USER'S MANUAL Bootup Num-Lock Use this feature to set the Power-on state for the Numlock key . The options are Off and On . W ait For 'F1' If Error If this f eature is set to Enabled , th e syste m wil l wait u ntil t he ' F 1' ke y i s pr es sed wh en an e rr or o cc ur s. T he op tio ns ar e D[...]
-
Page 91
Chapter 7: BIOS 7-5 CPU Con fi guration This submenu displays the information of the CPU as detected by the BIOS. It also allows the user to con fi gure the CPU settings. Socket 1 CPU Information/Socket 2 CPU Information This submenu displays the following information regarding the CPU installed in Socket 1 or Socket 2. • T ype of CPU ?[...]
-
Page 92
7-6 SUPERSERVER 6028R-WTR(T) USER'S MANUAL RTID (Record T ypes IDs) This feature displays the total number of Record T ype IDs for local and remote pools. The options are Optimal and Alternate. Hyper-threading Select Enabled to support Intel Hyper-threading T echnology to enhance CPU performance. The options are Enabled and Disabled. Active Pr[...]
-
Page 93
Chapter 7: BIOS 7-7 DCU Streamer Prefetcher (A vailable when supported by the CPU) Select Enabled to support Data Cache Unite (DCU) prefetch to speed up data accessing and processing in the DCU to enhance CPU performance. The options are Disabled and Enabled . DCU IP Prefetcher Select Enabled for DCU (Data Cache Unit) IP Prefetcher support, which w[...]
-
Page 94
7-8 SUPERSERVER 6028R-WTR(T) USER'S MANUAL C1E Support (A vailable when Power T echnology is set to Custom) Select Enabled to enable Enhanced C1 Power State to boost system performance. The options are Enabled and Disabled. CPU C3 Report (A vailable when Power T echnology is set to Custom) Select Enabled to allow the BIOS to report the CPU C3 [...]
-
Page 95
Chapter 7: BIOS 7-9 Long Duration Maintained This item displays the period of time (in seconds) during which long duration power is maintained. The default setting is 0 . Recommended Short Duration Power Limit This item displays the short duration power settings (in watts) recommended by the manufacturer . Short Duration Power Limit During T urbo M[...]
-
Page 96
7-10 SUPERSERVER 6028R-WTR(T) USER'S MANUAL Intel ® I/OA T Select Enabled to enable Intel I/OA T (I/O Acceleration T echnology), which will significantly reduce CPU overhead by leveraging CPU architectural improvements and freeing the system resource up for other tasks. The options are Disabled and Enabled . DCA Support Select Enabled to use [...]
-
Page 97
Chapter 7: BIOS 7-1 1 QPI (Quick Path Interconnect) Link Speed Mode Use this feature to select data transfer speed for QPI Link connections. The options are Fast and Slow . QPI Link Frequency Select Use this feature to select the desired QPI frequency . The options are Auto , 6.4 GT/s, 7.2 GT/s, and 8.0 GT/s. Memory Con fi guration • Current[...]
-
Page 98
7-12 SUPERSERVER 6028R-WTR(T) USER'S MANUAL Channel Interleaving This feature selects from the different channel interleaving methods. The options are Auto , 1 Way , 2 W ay , 3, W ay , and 4 W ay . Rank Interleaving This feature allows the user to select a rank memory interleaving method. The options are Auto , 1 W ay , 2 W ay , 4, Way , and 8[...]
-
Page 99
Chapter 7: BIOS 7-13 South Bridge This feature allows the user to con fi gure the settings for the Intel PCH chip. PCH Information This feature displays the following PCH information. Name : This item displays the name of the PCH chip. Stepping : This item displays the PCH stepping. USB Devices : This item displays the USB devices detected by [...]
-
Page 100
7-14 SUPERSERVER 6028R-WTR(T) USER'S MANUAL SA T A Con fi guration When this submenu is selected, the AMI BIOS automatically detects the presence of IDE or SA T A devices and displays the following items. SA T A Port0~SA T A Port5 : The AMI BIOS displays the status of each SA T A port as detected by the BIOS. SA T A Mode Use this feature [...]
-
Page 101
Chapter 7: BIOS 7-15 SA T A RAID Option ROM/UEFI Driver Select Enabled to boot the system from a SA T A RAID device or a UEFI (Uni fi ed Extensible Firmware Interface) device. The options are Enabled or Disabled. Port 0~5 Hot Plug Select Enabled to enable hot-plug support for a port speci fi ed by the user . The options are Enabled and Disabled. [...]
-
Page 102
7-16 SUPERSERVER 6028R-WTR(T) USER'S MANUAL ASPM Support This feature allows the user to set the Active State Power Management (ASPM) level for a PCI-E device. Select Auto to allow the system BIOS to automatically set the ASPM level for the system. Select Disabled to disable ASPM support. The options are Disabled and Auto. W arning : Enabling [...]
-
Page 103
Chapter 7: BIOS 7-17 Super IO Con fi guration Super IO Chip Displays the Super IO chip type. COM 1 Con fi guration Serial Port Select Enabled to enable a serial port speci fi ed by the user . The options are Enabled and Disabled. Device Settings This item displays the settings of Serial Port 1. Change Settings This option speci fi es th[...]
-
Page 104
7-18 SUPERSERVER 6028R-WTR(T) USER'S MANUAL SOL (Serial_Over_LAN) Device Mode Use this feature to select the desired mode for the SOL port. The options are Normal and High Speed. Serial Port 2 Attribute Use this feature to select the attribute for serial port 2. The options are SOL (Serial_On_LAN), and COM. Device Mode Use this feature to sele[...]
-
Page 105
Chapter 7: BIOS 7-19 Data Bits Use this feature to set the data transmission size for Console Redirection. The options are 7 and 8 (Bits). Parity A parity bit can be sent along with regular data bits to detect data transmission errors. Select Even if the parity bit is set to 0, and the number of 1's in data bits is even. Select Odd if the pari[...]
-
Page 106
7-20 SUPERSERVER 6028R-WTR(T) USER'S MANUAL Putty Keypad Use this feature to select function key and keypad setting on Putty . The options are VT100 , LINUX, XTERMR6, SCO, ESCN, and VT400. Redirection After BIOS POST If Always Enabled is selected, Legacy Console Redirection will be enabled for Legacy OS after BIOS POST (Power-On Self T est) is[...]
-
Page 107
Chapter 7: BIOS 7-21 Flow Control This feature allows the user to set the fl ow control for Console Redirection to prevent data loss caused by buffer over fl ow . Send a "Stop" signal to stop sending data when the receiving buffer is full. Send a "Start" signal to start sending data when the receiving buffer is empty . The opt[...]
-
Page 108
7-22 SUPERSERVER 6028R-WTR(T) USER'S MANUAL High Precision Event Timer Select Enabled to activate the High Precision Event Timer (HPET) that produces periodic interrupts at a much higher frequency than a Real-time Clock (RTC) does in synchronizing multimedia streams, providing smooth playback, reducing the dependency on other timestamp calcula[...]
-
Page 109
Chapter 7: BIOS 7-23 Intel TXT(L T -SX) Con fi guration This feature indicates if the following hardware components support the Intel TXT (T rusted Execution T echnology), which helps protect against software-based attacks and ensures protection, con fi dentiality and integrity of data stored or created on the system. • CPU/Chipset TXT Feat[...]
-
Page 110
7-24 SUPERSERVER 6028R-WTR(T) USER'S MANUAL Runtime Error Logging Support Change this item to enable or disable runtime error logging. The options are Enabled and Disabled. Memory Correction Error Threshold Change this item to de fi ne the system's memory correction error threshold. Directly enter a numeric value. The default value is 10[...]
-
Page 111
Chapter 7: BIOS 7-25 7-5 IPMI Use this menu to con fi gure Intelligent Platform Management Interface (IPMI) settings. System Event Log Enabling/Disabling Options SEL Components Select Enabled for all system event logging at bootup. The options are Enabled and Disabled. Erasing Settings Erase SEL Select 'Y es, On next reset' to erase [...]
-
Page 112
7-26 SUPERSERVER 6028R-WTR(T) USER'S MANUAL When SEL is Full This feature allows the user to decide what the BIOS should do when the system event log is full. Select Erase Immediately to erase all events in the log when the system event log is full. The options are Do Nothing and Erase Immediately . BMC Network Con fi guration LAN Channel[...]
-
Page 113
Chapter 7: BIOS 7-27 7-6 Boot Th is m enu all ows the us er to con fi gure t he fo llow in g bo ot set ti ngs f or t he syst em. Set Boot Prioriti es 1 st Boot De vic e/2nd Boot D evice/3rd Boot Device/4th Boot De vic e/5th Boot De vice/6t h Boot Device Use t his f eatur e to sp ec if y t he se quen c e of bo ot pr ior it y f or a dev ic e spe ci [...]
-
Page 114
7-28 SUPERSERVER 6028R-WTR(T) USER'S MANUAL USB Hard Disk Drive BBS Priorities This submenu allows the user to specify the boot priority sequence of a USB hard drive. 1st Device Network Device BBS Priorities This submenu allows the user to specify the boot priority sequence of a network device. 1st Device UEFI Boot Device BBS Prior[...]
-
Page 115
Chapter 7: BIOS 7-29 Pas sword Ch ec k This item allows you to decide when the system should check for a password after it has been entered. Select Setup for the system to prompt for a password before the user enters the BIOS Setup utility . Select Always for the system to prompt for a password upon each system boot and before the user enters the S[...]
-
Page 116
7-30 SUPERSERVER 6028R-WTR(T) USER'S MANUAL Save Changes and Reset When you have completed the system con fi guration changes, select this option to save the changes and reboot the computer so that the new system con fi guration settings can take effect. Select Save Changes and Exit, and press <Enter>. When the dialog box appears, aski[...]
-
Page 117
Chapter 7: BIOS 7-31 Boot Override This feature allows the user to override the Boot Option Priorities setting in the Boot menu, and instead immediately boot the system with one of the listed devices. This is a one-time override.[...]
-
Page 118
7-32 SUPERSERVER 6028R-WTR(T) USER'S MANUAL Notes[...]
-
Page 119
A-1 Appendix A: BIOS POST Error Codes Appendix A BIOS Error Beep Codes During the POST (Power-On Self-T est) routines, which are performed at each system boot, errors may occur . Non-fatal errors are those which, in most cases, allow the system to continue to boot. The error messages normally appear on the screen. Fatal errors will not allow the sy[...]
-
Page 120
A-2 SUPERSERVER 6028R-WTR(T) USER'S MANUAL Notes[...]
-
Page 121
B-1 Appendix B: System Speci fi cations Appendix B System Speci fi cations Processors Single or dual Intel® Xeon E5-2600v3 Series processors. Note: If using a single processor only , then slots SXB1B and SXB2 (lower left) will NOT be functional Note: Please refer to our web site for a complete listing of supported processors. Chipset Intel PCH-C[...]
-
Page 122
B-2 S UPER S ERVER 6027R-73DARF User's Manual Weight 57 lbs. (25.9 kg.) System Cooling Three 8-cm system cooling fans Note: The system cooling fans are redundant, hot-plug. System Input Requirements AC Input V oltage: 100 - 240V AC auto-range Rated Input Current: 9 - 3.5A max Rated Input Frequency: 50 to 60 Hz Power Supply Output Rated Output [...]
-
Page 123
B-3 Appendix B: System Speci fi cations Notes[...]
-
Page 124
B-4 S UPER S ERVER 6027R-73DARF User's Manual (continued from front) The products sold by Supermicro are not intended for and will not be used in life support systems, medical equipment, nuclear facilities or systems, aircraft, aircraft devices, aircraft/emergency com- munication devices or other critical systems whose failure to perform be re[...]