Go to page of
Similar user manuals
-
Network Card
SysKonnect SK-54C1
72 pages 1.19 mb -
Network Card
SysKonnect 9821
35 pages 1.22 mb -
Network Card
SysKonnect SK- 9841
35 pages 1.22 mb -
Network Card
SysKonnect SK-98xx
66 pages 1.16 mb -
Network Card
SysKonnect 9861
35 pages 1.22 mb -
Network Card
SysKonnect SK-98xx V2.0
66 pages 1.12 mb -
Network Card
SysKonnect 9822
35 pages 1.22 mb -
Network Card
SysKonnect 9843
35 pages 1.22 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of SysKonnect SK-9Sxx, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of SysKonnect SK-9Sxx one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of SysKonnect SK-9Sxx. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of SysKonnect SK-9Sxx should contain:
- informations concerning technical data of SysKonnect SK-9Sxx
- name of the manufacturer and a year of construction of the SysKonnect SK-9Sxx item
- rules of operation, control and maintenance of the SysKonnect SK-9Sxx item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of SysKonnect SK-9Sxx alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of SysKonnect SK-9Sxx, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the SysKonnect service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of SysKonnect SK-9Sxx.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the SysKonnect SK-9Sxx item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
SysKonnect SK-9Exx/9Sxx User Manual SK-9Exx and SK-9Sxx Gigabit Ethernet Server Adapters[...]
-
Page 2
[...]
-
Page 3
SysKonnect SK-9Exx/9Sxx Gigabi t Ethernet Server Adapters SysKonnect SK-9Exx and SK-9Sxx Gigabit Ethernet Server Adapters User Manual (v1.00 / 4 January , 2005) Visit our web site: http://www .syskonnect.com[...]
-
Page 4
4 Copyright © SysKonnect GmbH, 2004. All righ ts reserved. This manual refers to the ada pters of the SysK onnect SK- 9Exx/9Sxx Gigabit Ethernet Adapter Fam- ily . It describes the hardware and so ftware installation and the functionality of the adapters. Contents ar e subject to change. Product and br and names are (registe red) trademarks of the[...]
-
Page 5
SysKonnect SK-9Exx/9Sxx Gigabi t Ethernet Server Adapters Conventions The following conventions apply to this manual. W arnings and Notes Font S tyles applied Used to ind icate a pote ntially hazardo us situation w hic h, if not avoided, could result in death or seri- ous injury . Example: dangerous volt age. Used to indica te a potentially hazardo[...]
-
Page 6
6 Conventions Courier : Courier is used for the following element s: • T ermina l input to be entered by the user • T ermina l output issued by the system Examples: Enter sk98diag . If the test was successful, the message passed is issued. Underline Underline is used to identify hyper links. Example: Visit our web site: http://www . syskonnect.[...]
-
Page 7
SysKonnect SK-9Exx/9Sxx Gigabi t Ethernet Server Adapters T able of Contents Conventions 5 W arnings an d Notes 5 Font S tyles applied 5 Safety Precau tions 11 Avoid ing injuries 11 Avoid ing damage 11 1 Inst allation of the Network Adapt er 13 2 Connection of the Network Adapter 15 T r ansmission Distances 15 Connection to the Networ k 15 3 Inst a[...]
-
Page 8
8 T able of Conte nts Additional Functions of the Diagnostics Program 35 Checking Other Displays and Dat a 35 S tarting the Mai n Program 35 Reading Sensor Dat a 36 Reading Configuration Dat a 36 Reading V ital Produ ct Data (VPD) 37 Sample Usage of VPD / Asset T ag 38 7 T roubleshooting 41 8 Importa nt Information 43 T echnical Support 43 Returnin[...]
-
Page 9
SysKonnect SK-9Exx/9Sxx Gigabi t Ethernet Server Adapters T able of Figures Figure 1: Insertion of the adapter into the compu ter 14 Figure 2: Connection of fiber-optics cables/plugs 16 Figure 3: Possible network configurations / connection options 23 Figure 4: Location of the LEDs (adapter variant 1) 25 Figure 5: Location of the LEDs (adapter vari[...]
-
Page 10
10 T a ble of Figures[...]
-
Page 11
SysKonnect SK-9Exx/9Sxx Gigabi t Ethernet Server Adapters Safety Precautions T o protect yourself from injuries and avoid damage of the device, always obser ve the following safe- ty instructions when inst alling the network adapter . Avoiding injuries T o avo id potential shoc k hazards: • Do not carry out any installa tion, maintenance, or (re)[...]
-
Page 12
12 Safety Precautions For 1000Base-LX/SX adapters o bserve the following: The laser component s on the network adap ter are Class 1 laser component s. Class 1 lasers are considered incap able of producing damaging radi ation levels during normal oper ation or mainte- nance and is, therefore, determin ed to be eye safe. T o avoid damaging your eyes [...]
-
Page 13
SysKonnect SK-9Exx/9Sxx Gigabi t Ethernet Server Adapters 1 Installation of the Network Adapter The installa tion procedure in Hot- Plug systems may dif fer from the followin g. For Hot-Plug systems read the correspo nding document ation. Have the co mputer manual ready and if necessary , a key and/or scr ewdriver to open the c over and re move the[...]
-
Page 14
14 1 Installation of the Network Adapter Figure 1. Insertion of the ada pter into the compute r[...]
-
Page 15
SysKonnect SK-9Exx/9Sxx Gigabi t Ethernet Server Adapters 2 Connection of the Network Adapter This chapter describes the physical connection of the network ad apter to the network. General in- structions for drive r installation are given in chapter 3 “In stallation of the Driver Software”. T ransmission Distances Depending on the physi cal med[...]
-
Page 16
16 2 Connection of the Network Adapter Figure 2. Connection of fiber-optics cable s/plugs 7. T urn on the computer and the switch. If no protocol driver has been loaded, go to chapter 3 “Inst allation of the Driver Softwar e”. After driver inst allation, retu rn to step 8 of this list. 8. Check the link LED(s) to find out if the cable is connec[...]
-
Page 17
SysKonnect SK-9Exx/9Sxx Gigabi t Ethernet Server Adapters 3 Installation of the Driver Software The network drivers are located in th e appropriate prod uct directory on the enclo sed inst allation CD- ROM and on the SysKonn ect web site. The directory on the CD-ROM is organi zed into a numb er of subdirectories for the various o perating systems. [...]
-
Page 18
18 3 Installation of the Driver Software Windows SysKonnec t offers drivers for Wind ows Serve r 2003, Windows XP , Windows 2000, Win dows Me, Windows 98 SE, and Windows NT 4.0. Drivers downloaded from o ur web site are available in a packed fo rmat (.zip files). The do wnloaded file has to be unp acked before inst allation. Windows NT 4.0 The NDIS[...]
-
Page 19
SysKonnect SK-9Exx/9Sxx Gigabi t Ethernet Server Adapters Windows 19 Windows 98 Second Edition SysKonnect of fers an NDIS 5.0 32 -bit Miniport driver for the SysKonnect SK-9 Exx/9Sxx Gigabit Ethernet Server Adapte r Family supporting Wind ows 98 Second Edition (Windows 98 SE). This driver only supports Windo ws 98 SE and Windows Me. Due to the plug[...]
-
Page 20
20 3 Installation of the Driver Software 7. T ype the path to the driver , e.g. e:SK-9ExxWindowsWinME , where “e” is the desig nation of the CD-ROM drive on your system. 8. Click N EXT . The window “Location of driver” is displayed. 9. Click N EXT to continue the installation. The menu “Windows has finis hed installing the new hardw ar[...]
-
Page 21
SysKonnect SK-9Exx/9Sxx Gigabi t Ethernet Server Adapters Linux 21 Windows XP and Windows Server 2003 SysKonnect of fers an NDIS 5.1 32 -bit Miniport driver for the SysKonnect SK-9 Exx/9Sxx Gigabit Ethernet Server Adapter Family su pporting Windows XP and Windo ws Server 2003. The insta llation procedure for Windo ws XP and Window s Server 2003 is [...]
-
Page 22
22 3 Installation of the Driver Software Using the option E XPERT I NSTA LLATION , the driver is also compiled automatically and the resulting driver module object file is inst alled in a suitable location (similar to U SER I NSTALLATION ). No source files of the driver are ins talled into the kernel dire ctory . Only the driver module object file [...]
-
Page 23
SysKonnect SK-9Exx/9Sxx Gigabi t Ethernet Server Adapters 4 Hardware Features The SysKonnect SK-9Exx/ SK-9Sxx Gigabit Ethernet Adapter Family defines a series of network interfaces that combine server and workst ation co mputers with th e high-speed Gigabit Ethe rnet net- work (1000 Mbit/s) usin g fiber-optic and copper c a bles. At present there a[...]
-
Page 24
24 4 Hardware Features Adapter Characteristics The following table list s the characteristics of the SysKonnect SK-9Exx/9Sxx Gigabit Etherne t Serv- er Adapter Fam ily. SysKonnect SK-9Exx Adapters (PCI Express) SysKonnect SK-9Sxx Ad apters (PCI/PCI-X) The type of port on the network adap ter mu st be identical with that on the switch. SK-9E21 SK-9E[...]
-
Page 25
SysKonnect SK-9Exx/9Sxx Gigabi t Ethernet Server Adapters LED Displays 25 LED Displays Once the driver has been inst alled, the adapte r is operation al. The current status and speed are in- dicated by the LEDs. Adapter V ariant 1 Figure 4. Location of the LEDs (adapte r variant 1) The LEDs of the copper adapters var iant 1 have the following meani[...]
-
Page 26
26 4 Hardware Features Adapter V ariant 2 Figure 5. Location of the LEDs (adapte r variant 2) The LEDs of the copper adapters var iant 2 have the following meani ng: The LEDs of the fiber adapters var iant 2 have the fo llowing meaning: Marking on bracket Color St atus Description 10=OFF 100=GRN 1000=ORG OFF S peed 10 Mbit/s green ON S peed 100 Mbi[...]
-
Page 27
SysKonnect SK-9Exx/9Sxx Gigabi t Ethernet Server Adapters 5 Software Features Operating System Support The drivers for the SysKonnect SK-9Exx/9Sxx Gig abit Ethernet Server Adapter Family support the following operating systems: • Windows NT 4.0, Windows 98 Second E dition, Windows M illennium Edition, Windows 2000, Windows XP , and Win dows Serve[...]
-
Page 28
28 5 Software Features PXE / RPL Support The SysKonnect SK-9Exx/9Sxx Gigabit Ethernet Serv er Ad apter Family support s both the standard PXE 2.1 ( Pre-Boot eXec ution Environment ) and the protocol RPL ( Remote Program Load ). This al- lows networked computers that are no t yet loaded with an operating system to b e configured and booted remote ly[...]
-
Page 29
SysKonnect SK-9Exx/9Sxx Gigabi t Ethernet Server Adapters User Diagnostics (DOS) 29 The following conditions have to be met in order fo r Hot-Plu g to work on SysKonnect Gigabit Ether- net Adapters: • The target system has PCI Express resp. PCI/ PCI-X Hot-Plug slots, i.e. the power ca n be switched on and off under the control of the operating sy[...]
-
Page 30
30 5 Software Features For several o perating systems, SysKonnect of fers dr ivers that support VL AN tagg ing and thus can be applied for VLAN servers and terminal unit s. For more information on Virtual LANs, re fer to the White Paper “Vir tual Networks”, which can be found on the inst allation CD-ROM under “White P apers” or on our web s[...]
-
Page 31
SysKonnect SK-9Exx/9Sxx Gigabi t Ethernet Server Adapters 6 T esting the Network Adapter Diagnostics Program The network adapter can b e tested with the supp lied diagnostics pr ogram (run ning on DOS). During testing the link of the tested port will be down, i.e. no data can be transfer red. The following tests are available: • Simple test witho[...]
-
Page 32
32 6 T e sting the Network Adapter T o test the adapter , proceed as follows: 1. Switch off th e computer . 2. If the computer is still connected to the data network, unplug the data cable from the network adapter’s port. 3. Connect the network adapte r as follows: • For the simple test: Insert the protective plugs into the port s. • For the [...]
-
Page 33
SysKonnect SK-9Exx/9Sxx Gigabi t Ethernet Server Adapters Diagnostics Program 33 Loopback Repeater T e st T o perform the loopback repeater test, you will hav e to connect th e adapter to anot her adapter in- stalled in a seco nd computer running in rep eater mode (furth er known as the “repeater computer” ). The computer in which the adap ter [...]
-
Page 34
34 6 T e sting the Network Adapter Failure of a T est Figure 8. T ypical error message from the diagnostics pr ogram For a test to be completed successfully , each of the following conditions must be met: • The network adapter operates correctly . • The network adapter is cabled corr ectly for the test or is equipped with the correct plug. • [...]
-
Page 35
SysKonnect SK-9Exx/9Sxx Gigabi t Ethernet Server Adapters Additional Functions of the Diagno stics Program 35 10. If necessary , remove the wrap plug from the port. 1 1. (Re)connect th e ports to the data network. Additional Functions of the Diagnostics Program Checking Other Displays and Data In addition to perfor ming the network adap ter tests, [...]
-
Page 36
36 6 T e sting the Network Adapter Reading Sensor Data T o r ead sensor data, proceed as follows: 1. S tart the main p rogram (see p age 35). 2. Select S HOW S ENSORS in the main menu. A separate window will be displaye d for the following sensor data: • T emperature of the board • V oltage on the PCI card (for PCI/PCI-X adapters only) • V ol[...]
-
Page 37
SysKonnect SK-9Exx/9Sxx Gigabi t Ethernet Server Adapters Additional Functions of the Diagno stics Program 37 Figure 10. Display of configuration data Reading V ital Pr oduct Data (VPD) T o read VPD, proceed as follows: 1. S tart the main p rogram (see p age 35). 2. Select VPD D ATA in the main menu. A submenu with the following options will be dis[...]
-
Page 38
38 6 T e sting the Network Adapter 3. Select the desired option or return to th e main menu by selectin g E XIT (default option). Sample Usage of VPD / Asset T ag Example Y ou want to store the inventory number of the networ k adapter (123-45) in the asset tag. T o store the inventory number , proceed as follows: 1. Look at all the VPD to determine[...]
-
Page 39
SysKonnect SK-9Exx/9Sxx Gigabi t Ethernet Server Adapters Additional Functions of the Diagno stics Program 39 Figure 13. Screen showing updated asset tag For more information on the diag nostics program, refer to the corresp onding readme file.[...]
-
Page 40
40 6 T e sting the Network Adapter[...]
-
Page 41
SysKonnect SK-9Exx/9Sxx Gigabi t Ethernet Server Adapters 7 T roubleshooting If the problem persist s, you can analyze the st atus of th e network adapter with the aid of the LEDs and the diagnostics progr am. Problem What to do Another expansion card fails to work after the net- work adapter ha s been in- stalled Make sure all cab les are connecte[...]
-
Page 42
42 7 T roubleshooting[...]
-
Page 43
SysKonnect SK-9Exx/9Sxx Gigabi t Ethernet Server Adapters 8 Important Information T echnical Support If you encounter any pr oblems, read the relevant ch apter s of the manual and the re adme files on the CD-ROM. If you cannot solve your pr oblems, consult our technical support. If you contact our techn ical support engineers, have the following in[...]
-
Page 44
44 8 Important Information 2. Complete the form. 3. Return the form to us. We will send you a unique refer ence number and inform you if the product is still under war- ranty . 4. Send us the faulty pr oduct packed in an an tistatic bag, with a co py of the com pleted form enclosed in its original pack aging (or comparable packaging). 5. Write the [...]
-
Page 45
SysKonnect SK-9Exx/9Sxx Gigabi t Ethernet Server Adapters T echnica l S pecificatio ns 45 T echnical Specifications Network interfac e st andard IEEE 802.3 and IEEE 802.3u (E thernet and Fast Ethernet) IEEE 802.3ab and IEEE 802 .3z (Gigabit Ethernet) IEEE 802.3x (Flow-control and Auto-negotiation ) IEEE 802.1p (Quality of Services) IEEE 802.1q and [...]
-
Page 46
46 8 Important Information Dimensions (ma x.) (without bracket) SK-9E21: 1 18.4 mm x 60.3 mm SK-9S21: 167.64 mm x 57.3 mm SK-9E22: 1 18.4 mm x 68.94 mm SK-9S22: 167.64 mm x 64.41 mm SK-9E8x/SK-9E9x: 128.52 mm x 68.94 mm SK-9S8x/SK-9S9x: 167.64 mm x 64.41 mm T emperature range Operation: 0°C to + 50°C S to rage: -20°C to + 7 0°C Relative humidit[...]
-
Page 47
SysKonnect SK-9Exx/9Sxx Gigabi t Ethernet Server Adapters How to Identify your Network Adapter T ype 47 How to Identify your Network Adapter T ype If you are in any doubt, you can easily check whic h type of network adapter you have withou t having to open th e computer cover . Simply compare the ca rd ’s fixing plate (in p articular the ports an[...]
-
Page 48
48 8 Important Information Adapter V ariant 2 Model SK-9E21 SK-9S21 SK-9E 22 SK-9S 22 SK-9E81 SK-9S81 SK-9E82 SK-9S82 SK-9E91 SK-9S91 SK-9E92 SK-9S92 Bracket Interface/Port 10/100/ 1000Base-T Single Link 10/100/ 1000Base-T Dual Link 1000Base-SX Single Link 1000Base -SX Dual Link 1000Base-SX Single Link 1000Base-SX Dual Link Media Copper Copper Fib [...]
-
Page 49
SysKonnect SK-9Exx/9Sxx Gigabi t Ethernet Server Adapters Appendix A. License and W arranty Information The Americas, Asia, Australia, New Zealand, Pacific Dear Customer , if you acquired your SysKon nect product in the UNITE D ST A TES, CANA DA or any other country in the AMERICAS, ASIA, AUSTRALIA, NEW ZEALAND, P ACIFIC, the following license and [...]
-
Page 50
50 Appendix A. License and Warranty Information Customer Remedies SysKonnect's entire liability and your exclusive remedy shall be, at SysKonnect's option, either return of t he price paid, or r ep air or replacement of the SOFTW ARE or HARDW ARE that d oes not meet SysKonnect 's Li mited W arranty and which is returned to SysKonnect[...]
-
Page 51
SysKonnect SK-9Exx/9Sxx Gigabi t Ethernet Server Adapters Deutschland, Schweiz, Österreich, Liechtenstein 51 Hardware The risk passes to you, the end user , upon taking possession (hand over) of the HARDWA RE. T otal qualities were not warranted. Limited Warranty for Ha rdware and Software Limited Warranty SysKonnect warrant s that the SOFTW ARE w[...]
-
Page 52
52 Appendix A. License and Warranty Information anderen S peichervorrichtung eines Co mputers, der kein Netzser ver ist, instal liert wird und eine einzige Person diesen Compu ter zu mehr als 80 % der Zeit benut zt, die er in Benutzung ist, darf diese ei ne Pe rson die Soft ware auch auf einem tragbaren Computer oder eine m Heimcom- puter benutzen.[...]
-
Page 53
[...]
-
Page 54
V isit us: www .syskonnect.com SysKonnect GmbH Siemensstrasse 23 D-76275 Ettlingen Support: +49 7243 502 330 E-mail: sales@syskonnect.de[...]