Go to page of
Similar user manuals
-
Smoke Alarm
System Sensor 4WT-B
4 pages 0.11 mb -
Smoke Alarm
System Sensor 2WT-B
4 pages 0.11 mb -
Smoke Alarm
System Sensor DH500
12 pages 0.42 mb -
Smoke Alarm
System Sensor B114LP
2 pages 0.74 mb -
Smoke Alarm
System Sensor FTX-P1
4 pages 0.13 mb -
Stud Sensor
System Sensor EM-1RI
2 pages 0.12 mb -
Smoke Alarm
System Sensor 2451TH
4 pages 0.08 mb -
Smoke Alarm
System Sensor Intelligent Air Duct Smoke Detector Housing
12 pages 0.42 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of System Sensor DH100ACDCLWP, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of System Sensor DH100ACDCLWP one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of System Sensor DH100ACDCLWP. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of System Sensor DH100ACDCLWP should contain:
- informations concerning technical data of System Sensor DH100ACDCLWP
- name of the manufacturer and a year of construction of the System Sensor DH100ACDCLWP item
- rules of operation, control and maintenance of the System Sensor DH100ACDCLWP item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of System Sensor DH100ACDCLWP alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of System Sensor DH100ACDCLWP, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the System Sensor service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of System Sensor DH100ACDCLWP.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the System Sensor DH100ACDCLWP item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
D200-24-00 1 I56-0056-0 7R DH100ACDCL WP W ater tight Air Duct Smoke Detector with Extended Air Speed Range INST ALLA TION AND MAINTENANCE INSTRUCTIONS 3825 Ohio A v enue, St. Charles , Illinois 60 174 800/736-7672, F AX: 630-377-6495 www .s ystemsensor .com The Innov air DH1 00A CDCL WP is a photoelectric extended air speed range duct smok e detec[...]
-
Page 2
This device will not sense smok e unless the ventilation s ys- tem is operating and the co ver is installed. F or this detector to function pr operly , it MUST be installed according to the instructions in this manual. F urthermore , the detector MUST be operated within ALL electrical and environmental specifications listed in this manual. F ailure[...]
-
Page 3
e xhaust tube is molded onto the base of the duct housing, and the A2440-00 Exhaust T ube Extension is available as an accessory in those cases where the molded e xhaust port does not extend at least 2 inches into the duct. The sampling tube is alwa ys installed with the air inlet holes facing into the air flow . T o assist proper installation, the[...]
-
Page 4
NO TE: An alternate method to using the ST -1 0 is to use two ST -5 sampling tubes. R emo ve the flange from one of the tubes and install as described abov e . After the installation, use electrical tape to close off some of the sampling holes so that there ar e a total of 1 0 to 12 holes spaced as evenly as possible across the width of the duct. N[...]
-
Page 5
Before conducting these tests , notify the proper authorities that the smoke detection s ystem will be tempor arily out of service . Disable the zone or sy stem under test to prev ent unw anted alarms. [6.1] Smoke Entr y T ests [6.1.1] Air Flow The DH1 00A CDCL WP is designed to operate o ver an e xtended air speed r ange of 1 00 to 4000 FPM. T o v[...]
-
Page 6
15 19 14 3 20 1 3 2 Alarm Signal Aux. Power + Sup. N. O. Sup. COM Aux. Power – NOTE: Wiring diagram shown is for DH100ACDCLWP 4-wire duct smoke detector system equipped without a control panel. Alarm (Red LED) Power (Green LED) Common APA451 DH100ACDCLWP D200-24-00 6 I56-0056-0 7R Do not loop wire under terminals when wiring detector s. Br eak wi[...]
-
Page 7
detector board to cause a tr ouble condition locally and at the sy stem control panel. Cov er T amper — If the cov er is remo ved or not properly secur ed for a period longer than 7 minutes, a tr ouble signal is generated to indicate the co ver is missing. Figure 13. T esting detector alar m: H0 160-00 [6.2.2] Alarm T ests [6.2.2.1] M02-04-00 Mag[...]
-
Page 8
D200-24-00 8 I56-0056-0 7R Three-Y ear Limited Warranty Sy stem Sensor warrants its enclosed air duct smok e detector to be free from defects in materials and workmanship under normal use and service for a period of three y ears fr om date of manufacture . System Sensor mak es no other express warr anty for this air duct smoke detector . No agent, [...]