Telex SS-1002 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Telex SS-1002, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Telex SS-1002 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Telex SS-1002. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Telex SS-1002 should contain:
- informations concerning technical data of Telex SS-1002
- name of the manufacturer and a year of construction of the Telex SS-1002 item
- rules of operation, control and maintenance of the Telex SS-1002 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Telex SS-1002 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Telex SS-1002, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Telex service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Telex SS-1002.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Telex SS-1002 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    1 9350-7741-000 Rev A, 10/2002 User Instructions Model SS-1002 Single Channel Intercom S peaker S t ation Model SS-2002 T wo Channel Intercom S peaker S t ation Model SS-2002RM T wo Channel Rack Mount Intercom S peaker S t ation Audiocom ® Intercom Systems[...]

  • Page 2

    2 FCC S t atement This equipment uses, and can radiate radio frequency energy that may cause interference to radio com- munications if not installed in accordance with this manual. The equipment has been tested and found to comply with the limits of a Class A computing device pursuant to Subpart J, Part 15 of FCC Rules which are designed to provide[...]

  • Page 3

    3 T able of Content s Intr oduction ............................................................................... 4 Description ................................................................................ 4 Featur es ..................................................................................... 4 Installation ..........................[...]

  • Page 4

    4 Introduction Thank you for purchasing the Audiocom SS-1002/SS-2002/SS-2002RM Intercom Speaker Station. W e hope the many design features of this product will satisfy your intercommunication requirements for many years to come. T o get the most out of your new intercom station, please take a few moments to look through this booklet before using th[...]

  • Page 5

    5 Figure 1 - SS-1002 / SS-2002 features. Figure 2 - SS-2002RM features.[...]

  • Page 6

    6 Inst allation Unp acking Each SS-1002 / SS-2002 / SS-2002RM is supplied with the following items. Contact the shipper or your Audiocom dealer immediately if anything is damaged or missing. Be sure to fill out and return the product registration card to T elex to properl y register your intercom station. For SS-1002 / SS-2002 units: y t i t n a u [...]

  • Page 7

    7 Mic Kill Receive Audiocom master stations, such as the US-2002A, can transmit an inaudible signal to turn off the microphones in all remote intercom stations on an intercom channel. This is useful when a remote intercom station has been left unattended with the microphone on. The procedure to send a mic kill signal from a master station is a two-[...]

  • Page 8

    8 Headset Connector Notes If you are using a monaural, dynamic-mic headset, or a monaural, telephone-style, dynamic-mic handset, or a handheld dynamic microphone, plug it into the Headset connector . Y ou can also use this connector with monaural headphones for listening when you are using either the built in panel microphone, or the optional goose[...]

  • Page 9

    9 intercom stations may be reduced. Generally , if intercom stations are within a few hundred feet from the system power supply , phantom power will be suf ficient. Also note that increasing the number of stations will reduce the overall operating distance. Phantom power is generally the only method that will be used to connect the “S” box, “[...]

  • Page 10

    10 All Locally P owered Inter com Stations (Dry Lines) If intercom stations are widely distributed, you can dispense with a system power supply (PS2001L, SPS-2001, etc.) and use local power for each station. When no power is delivered on the intercom channels, this is known as dry-line operation. Since a system power supply is not used, a line term[...]

  • Page 11

    11 Figure 9 - Audiocom mode connections for an SS1002 Intercom S tation in a “U” box. Note: for Clear-Com connection, use the Unbal anced Mode Intercom Channel pin-out information listed in the Specifications section.[...]

  • Page 12

    12 Figure 10 - Audiocom mode connections for an SS2002 Intercom S tation in a “U” box. Note: for Clear-Com connection, use the Unba lanced Mode Intercom Channel pin-out information listed in the Specifications section.[...]

  • Page 13

    13 Figure 1 1 - Audiocom cable wiring diagrams.[...]

  • Page 14

    14 Power-Up Make sure any local power supplies are plugged in, then turn on the power switches of any phantom power supplies (PS- 2001L, SPS-2001, etc.) Sidetone Adjustment The SS-1002, SS-2002, and SS-2002RM use full-duplex audio (the same as conventional telephone lines) in which the talk and listen audio are sent and received on the same wires. [...]

  • Page 15

    15 Operation Channel Select (SS-2002 & SS-2002RM Only) T ap the Ch Select key to select channel 1 or 2. The key is green when channel 1 is selected and red when channel two is selected. Headset/Headphone/S peaker/Microphone Selection • T o use a headset or telephone style handset, set the Speaker and Panel Mic keys to off. • T o use headpho[...]

  • Page 16

    16 S pecifications General Power Requir ements: Phantom Power: +24 VDC nominal, 175 mA Local Power: +12 to +15 VDC, 250 mA Dimensions: See dimension drawings. Environmental Requir ements: S torage: -20°C to 80°C; 0% to 95% RH, non-condensing Operating: -15°C to 60°C; 0% to 95% RH, non-condensing Dynamic-mic Headset/Handset Microphone: 50 to 200[...]

  • Page 17

    17 Call Signaling: Pin 1 - Common Pin 2 - Local power (+12 to +15 VDC) If needed Pin 3 - Power +30 V DC Pin 4 - Intercom channel 1 audio and DC call signaling Pin 5 - Power +30 V DC Pin 6 - Intercom channel 2 audio and DC call signaling Speaker Output Power 4W max @ 8 ohms Dimensions[...]

  • Page 18

    18 TRADEMARKS Audiocom ® is a registered trademark of T elex Comm unications. Names of other products mentioned herein are used for identification purposes only and may be trademarks and/or registered trademarks of their respectiv e companies. W ARRANTY INFORMA TION Products are warranted b y T elex Comm unications, Inc. to be free from defects in[...]