A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Thermador SB2B, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Thermador SB2B one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Thermador SB2B. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Thermador SB2B should contain:
- informations concerning technical data of Thermador SB2B
- name of the manufacturer and a year of construction of the Thermador SB2B item
- rules of operation, control and maintenance of the Thermador SB2B item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Thermador SB2B alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Thermador SB2B, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Thermador service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Thermador SB2B.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Thermador SB2B item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
Installation Instructions and Owner's Man ual for Thermador Outdoor Cooktop Model SB2B WARNING: If the information in this manual is not f ollow ed exactly , a fire or explosion ma y result causing pr operty damage , personal injur y or death. ▲ ! AVERTISSEMENT: Si l’information dans ce manuel n’est pas suivie exactement, une incendie ou[...]
-
Page 2
A Special Messa g e to Our Customers Thank you for selecting the Thermador® Outdoor Cooktop. We recom- mend that you take time to read this entire booklet before using your new appliance for the first time. This booklet contains important safety information, installation instructions, operation and care suggestions. Keep it in a handy place as it [...]
-
Page 3
Contents SECTION 1: Safety Information ............................................................. 2-4 SECTION 2: Gas Requirements ................................................................... 5 Natural Gas Requirements .......................................................................... 5 Pr opane Gas Requirements ...................[...]
-
Page 4
TESTED IN ACCORDANCE WITH ANSI Z21.58 – 1995, ANSI Z21.58a – 1998 STANDARD FOR OUTDOOR COOKING GAS APPLIANCES, AND CAN/CGA 1.6 – M95, CGA 1.6a – M98, STANDARD FOR OUTDOOR COOKING GAS APPLIANCES. This unit is for outdoor use onl y in a w ell-v entilated area. Not to be used in a building, garage or an y other enclosed area. Check your local [...]
-
Page 5
IMPORTANT INFORMATION This outdoor gas cooking appliance is not intended to be installed in or on recreational vehicles and/or boats. Always inspect the natural gas or LP gas hose assembly before each use of the appliance. If there is evidence of excessive abrasion or wear, or if the hose is cut, it must be replaced prior to the appliance being put[...]
-
Page 6
SECTION 1: SAFETY PRA CTICES T O A V OID PERSONAL INJUR Y LP TANK REQUIREMENTS This model can be converted for use with an LP cylinder which can be purchased locally from an LP supplier or other retail outlet. The cylinder must be constructed and marked in accordance with the specifications for LP-gas cylinders of the U.S. Department of Transportat[...]
-
Page 7
NA TURAL GAS REQUIREMENTS - Inlet Connection: 1/2" NPT Supply Pressure: 6" to 14" W.C. Manifold Pressure: 5" W.C. PROP ANE GAS REQUIREMENTS - Inlet Connection: 1/2" NPT Supply Pressure: 11" to 14" W.C. Manifold Pressure: 10" W.C. SECTION 2: GAS REQUIREMENTS GAS CONSUMPTION The total gas consumption of the The[...]
-
Page 8
SECTION 3: SITE PREP ARA TION BUILT-IN INSTALLATIONS Determine a suitable location for the cooktop by taking into account exposure to wind and availability of gas and electrical supplies. Insure that the gas supply line and electrical supply are located in close proximity to the unit. The 8-foot-long electrical cord attached to the cooktop exits fr[...]
-
Page 9
SECTION 4: ELECTRICAL REQUIREMENTS AND GROUNDING INSTR UCTIONS Cooktop Three-Prong Plug and Receptacle Figure 2 AVERTISSEMENT Instruction pour la mise a la terre electrique Cet appareil est muni d’une fiche a trots broches (mise a la terre) afin de vous proteger des chocs et doit etre branche dire~ement dans une prise de courant a trots broches a[...]
-
Page 10
SECTION 5: UNP A CKING AND PLA CING THE UNIT LOCA TING Y OUR OUTDOOR COOKT OP Unpack and remove all accessory items, packing materials and product literature from the unit. Attach the gas pressure regulator to the end of the manifold as shown in Figure 3. Note the direction of gas flow. Connect one end of an approved outdoor gas supply hose to the [...]
-
Page 11
6. The cooktop is supplied with a pressure regulator that is packed with the unit. The regulator is set for natural gas. For use with propane, it must be converted. The regulator will be located on the left rear bottom of the unit. Using a flat blade screwdriver, remove the cap on the top of the regulator and turn the cap over so that the letters L[...]
-
Page 12
7. If the cooktop will be used with an LP cylinder, follow these steps: A . The Model LPHose is available at your Thermador dealer. B. This assembly can also be purchased locally providing it meets the following specifications: Hose length to be 24". Regulator must be a high pressure, high volume unit capable of supplying adequate gas flow bas[...]
-
Page 13
GAS AND ELECTRICAL HOOK-UP With the unit inside of the enclosure, connect the gas supply hose to the manual shut-off valve and open valve. Check the connection points at the shut-off valve for any leaks and repair prior to installation of the unit. See Figures 11 and 12. Connect the power supply cord to the electrical supply outlet. Figure 12 Leak [...]
-
Page 14
SECTION 6: TEST AND ADJUSTMENT BURNER AIR ADJUSTMENT All burners are adjusted for proper flame characteristics at time of assembly. All burners should exhibit flames which are blue and stable, with no yellow-tipping, lifting or excessive noise when operating on either natural or LP gases. If any of the flame characteristics noted above are observed[...]
-
Page 15
SECTION 7: USING YOUR OUTDOOR COOKT OP GENERAL BURNER INFORMA TION • Each burner is rated at 15,000 BTU on High. • Choose a pan base to fit the flame size. The flame should never extend beyond the base of the pan. • Never turn on a burner without removing the cover. • When not in use, place the stainless steel cover over the grate. USING TH[...]
-
Page 16
SECTION 8: CARE AND CLEANING The quality of this material resists most stains and pitting, providing the surface is kept clean and protected with a stainless steel polish. Nonabrasive Cleaners: detergent and water, Fantastik ® , 409 ® , vinegar. Mild abrasive Cleaners: liquid Kleen King ® Stainless Steel Polish: Stainless Steel Magic ® • When[...]
-
Page 17
__________________________________ Model Number __________________________________ Serial Number __________________________________ Date of Purchase __________________________________ Dealer’s Name __________________________________ Dealer’s Phone Number __________________________________ Service Center’s Name ________________________________[...]
-
Page 18
Full One-Y ear W arranty Covers one year from the date of installation or date of occupancy for a new previously unoccupied dwelling. Save your dated receipt or other evidence of the installation/occupancy date. Thermador ® Will Pay For: All repair labor and replacement parts found to be defective due to materials and workmanship. Service must be [...]
-
Page 19
5551 McFadden Avenue, Huntington Beach, CA 92649 • 800/735-4328 ECO14028 • 08-04-638B • © BSH Home Appliances Corp. • Litho U. S. A. 4/00 Specifications are f or planning purposes only . Refer to installation instructions and consult your countertop supplier prior t o making counter opening. Consult with a heating and ventilating engineer [...]