Go to page of
Similar user manuals
-
Air Conditioner
Toshiba RAV-SM1106BT-E
104 pages 1.49 mb -
Air conditioner
Toshiba MMY-MAP1404T8-E
22 pages 2.34 mb -
Air conditioner
Toshiba MCY-MAP0401HT
81 pages 2.82 mb -
Air Conditioner
Toshiba RAV-SM1406BT-TR
104 pages 1.49 mb -
Air Conditioner
Toshiba RAV-SM1100UT-E
80 pages 3.03 mb -
Air conditioner
Toshiba RAS-13UKP-ES
32 pages -
Air Conditioner
Toshiba RAV-SM803AT-E
195 pages 5.79 mb -
Air Conditioner
Toshiba RAV-SM2244AT7Z
133 pages 4.98 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Toshiba RAV-SM562AT-E, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Toshiba RAV-SM562AT-E one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Toshiba RAV-SM562AT-E. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Toshiba RAV-SM562AT-E should contain:
- informations concerning technical data of Toshiba RAV-SM562AT-E
- name of the manufacturer and a year of construction of the Toshiba RAV-SM562AT-E item
- rules of operation, control and maintenance of the Toshiba RAV-SM562AT-E item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Toshiba RAV-SM562AT-E alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Toshiba RAV-SM562AT-E, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Toshiba service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Toshiba RAV-SM562AT-E.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Toshiba RAV-SM562AT-E item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
AIR CONDITIONER (SPLIT TYPE) CLIMA TISEUR (TYPE SPLIT) KLIMA GERÄT (SPLIT -TYP) CONDIZIONA T ORE D'ARIA (TIPO SPLIT) AIRE A CONDICIONADO (TIPO SPLIT) AR CONDICIONADO (TIPO SPLIT) AIRCONDITIONER (GESPLITST TYPE) ÊËÉÌÁÔÉÓÔÉÊÏ (ÄÉÁÉÑÏÕÌÅÍÏÕ ÔÕÐÏÕ) <Under Ceiling T ype> / <T ype sous le plaf ond> <Zwisc[...]
-
Page 2
ADOPTION OF NEW REFRIGERANT This Air Conditioner is a ne w type which adopts a ne w refrigerant HFC (R410A) instead of the con v entional refriger- ant R22 in order to pre v ent destruction of the ozone la yer . UTILISA TION DU NOUVEA U REFRIGERANT Ce climatiseur est d ’ un type in é dit qui utilise le nouv eau r é frig é rant HFC (R410A) au l[...]
-
Page 3
CONTENTS SOMMAIRE INHALT INDICE CONTENIDO Í NDICE ÐÅÑÉÅ×ÏÌÅÍÁ INHOUD ITALIANO ESPA Ñ OL PORTUGU Ê S ÅËËÇÍÉÊÁ FRANCAIS DEUTSCH NEDERLANDS ENGLISH A CCESSORIES (SOLD SEP A RA TEL Y) ......................................... 1 PRECA UTIONS FOR SAFETY ....................................................... 1 P ARTS NAME ..........[...]
-
Page 4
1 ON / OFF FA N TEMP . SWING/FIX TIME MODE VENT UNIT SET CL FIL TER RESET TEST TIMER SET CODE No. UNIT No. TEST SETTING DATA SET R.C. No. H A CCESSORIES (SOLD SEP ARA TEL Y) Remote controller PRECA UTIONS FOR SAFETY W ARNING W ARNINGS ABOUT INST ALLA TION • Make sure to ask the qualified installation prof essional in electr ic work to install the[...]
-
Page 5
2 ENGLISH CA UTION CA UTIONS ABOUT INST ALLA TION • Be sure to confir m the f ollo wing cautions . • Cer tainly lay the dr ain hose f or perfect draining. Bad drainage ma y cause flooding in the house and getting furniture wet. • Make sure to connect the air conditioner to an e xclusive pow er supply of the rated v oltage , otherwise the unit[...]
-
Page 6
3 Air inlet (Side and rear) Pipes and electric wires Air outlet Remote controller Button Button to open/close the suction por t Air filter Remov es dust or trash. (Provided on the suction port.) Dischar ge flap of dischar ge por t Change the direction of the air to be discharged according to cool/heat mode. Suction air port The air in the room is s[...]
-
Page 7
4 P ARTS NAME OF REMO TE CONTR OLLER Displa y section In the displa y e xample, all indicators are displa y ed f or the e xplana- tion. In reality only , the selected contents are indicated. • When tur ning on the leak breaker at the first time , [ SET DA T A ] flashes on the display part of the remote controller . While this displa y is flashing[...]
-
Page 8
5 Operation section Push each button to select a desired oper ation. • The details of the operation needs to be set up once, afterw ard, the air conditioner can be used b y pushing ON / OFF b utton only . 1 Air v olume select b utton Selects the desired air v olume mode. 2 Timer set button TIMER SET button is used when the timer is set up . 3 Che[...]
-
Page 9
6 1 Push ON / OFF button . The operation lamp goes on, and the operation starts. 2 Select an operation mode with the “MODE MODE ” button. One push of the button, and the displa y changes in the order shown on the right. • In HEA T mode, if the room temper ature reaches to the set temperature , the outdoor unit stops and the air flow becomes L[...]
-
Page 10
7 A UT OMA TIC OPERA TION (A uto Changeover) When you set the air conditioner in mode or s witch o v er from A UT O operation because of some settings change, it will automatically select either cooling, heating, or f an only operation depending on the indoor temperature. 1 2 3 ON / OFF FA N TEMP . SWING/FIX TIME MODE VENT UNIT SET CL FIL TER RESET[...]
-
Page 11
8 In F AN operation In all modes Display when stopping the s wing Initial setup Series of operation F an/Heat operation Cool/Dry operation ON / OFF FA N TEMP . SWING/FIX TIME MODE VENT UNIT SET CL FIL TER RESET TEST TIMER SET ADJUSTMENT OF WIND DIRECTION • When the air conditioner stops, the flap (adjustment plate of up/down wind direction) direc[...]
-
Page 12
9 TIMER OPERA TION A type of timer operation can be selected from the f ollowing three types . OFF timer : The operation stops when the time of timer has reached the set time. Repeat OFF timer : Every time, the operation stops after the set time has passed. ON timer : The operation star ts when the time of timer has reached the set time. Timer oper[...]
-
Page 13
10 HINTS FOR ECONOMICAL OPERA TION Maintain room temperature at comf or table level Clean air filters The clogged air filter impairs the perf ormance of the air conditioner . Never open door s and windows more often than necessary T o keep cool or w ar m air in the room, ne v er open doors and windows more often than necessar y . Window curtains In[...]
-
Page 14
11 If y ou do not plan to use the unit for more than 1 month (1) Oper ate the f an for 3 to 4 hours to dry inside the unit • Operate “ F AN ONL Y ” mode with set temperature 30 ° C. (2) Stop the air conditioner and turn off the main power s witch or the circuit breaker . Checks bef ore operation (1) Chec k that the air filters are installed.[...]
-
Page 15
12 AIR CONDITIONER OPERA TIONS AND PERFORMANCE 3 minutes pr otection function 3-minutes protection function pre v ents the air conditioner from star ting for initial 3 min utes after the main pow er s witch/circuit break er is tur ned on f or re-star ting the air conditioner . P ower failure P ower f ailure dur ing operation will stop the unit comp[...]
-
Page 16
13 RE-INST ALLA TION D ANGER Ask the dealer or an installation prof essional to re-install the air conditioner to a ne w place or mo ve it to another place and to observe the f ollowing items. If the air conditioner is inappropriate installed b y y our self , it ma y cause electric shoc k or fire. Do not install the air conditioner in the follo win[...]
-
Page 17
14 Before y ou ask f or servicing or repairs, check the f ollo wing points. Inoperative • The main power s witch is tur ned off. • The circuit breaker is activ ated to cut off power supply . • The main pow er fuse has b lown out. • Stoppage of electric current. Does not cool well or heat well • The air inlet and/or outlet of the outdoor u[...]
-
Page 18
EH99923701 TOSHIBA CARRIER CORPORA TION 2 CHOME 12-32, K ONAN, MINA TOKU, TOK YO , 108-0075, JAP AN This product is compliant with Directiv e 2002/95/EC , and cannot be disposed as unsor ted municipal waste . Ce produit est conf orme à la Directiv e 2002/95/CE et il ne peut pas ê tre jet é a v ec les ordures m é nag è res non tri é es. Dieses[...]