Toshiba XIDF-037A manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Toshiba XIDF-037A, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Toshiba XIDF-037A one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Toshiba XIDF-037A. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Toshiba XIDF-037A should contain:
- informations concerning technical data of Toshiba XIDF-037A
- name of the manufacturer and a year of construction of the Toshiba XIDF-037A item
- rules of operation, control and maintenance of the Toshiba XIDF-037A item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Toshiba XIDF-037A alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Toshiba XIDF-037A, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Toshiba service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Toshiba XIDF-037A.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Toshiba XIDF-037A item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    No. MIIXR0002EAC DICOM CONFORMANCE STATEMENT MEDIA STORAGE FOR TOSHIBA DIGITAL FLUOROGRAPHY SYSTEM MODEL DFP-2000A with XIDF-037A and XIDF-038A or SRS-1000A (MIIXR0002EAC) 2001[...]

  • Page 2

    No. MIIXR0002EAC IMPORTANT! (1) No part of this manual may be copied or reprinted, in whole or in part, without written permission. (2) The contents of this manual are subject to change without prior notice and without our legal obligation. C-1 *[...]

  • Page 3

    No. MIIXR0002EAC Table of Contents Page 1 INTRODUCT ION ................................................................................................................ 1 1.1 R EFERENCES ..................................................................................................... 1 1.2 D EFINITIONS ..........................................[...]

  • Page 4

    No. MIIXR0002EAC 8.1.1 Media Storage Directory IOD Modules ................................................................ 9 8.1.2 Media Storage XA IOD Modules .......................................................................... 9 8.1.3 XA IOD Modules ...........................................................................................[...]

  • Page 5

    No. MIIXR0002EAC 1 Introduction This document is a DICOM Conformance Statement for Toshiba's Digital Fluorography Systems. It is intended to provide the reader with the knowledge of how to integrate this product within DICOM compliant equipments. It details the DICOM Service Classes, Information Objects, and Application Profiles which are supp[...]

  • Page 6

    No. MIIXR0002EAC 1.3 Acronyms, Abbreviations and Sy mbols • ACC American College of Cardiology • ACR American College of Radiology • ASCII American Standard Code for Information Interchange • AE Application Entity • ANSI American National Standards Institute • AP Application Profile • CEN TC251 Comite Europeen de Normalisation - Techn[...]

  • Page 7

    No. MIIXR0002EAC 2 Implement ation Model 2.1 Application Data Flow Diagram Transfer of X-r a y Examinat ion DICOM Recording CD-R Medium Review of X-r a y Examinat ion DICOM Reader Legend Applicati on Entity Local Real-W orld Activi ty File-set Creator (FS C) File-set Reader (FS R) Local Relationship Figure 1 2.2 Functional Definitions of AE's [...]

  • Page 8

    No. MIIXR0002EAC 2.2.2 DICOM Reader The DICOM Reader supports the following tasks: • Reads the DICOMDIR file that represent s the contents of t he data as recorded. • Displays the ordered list of patient and image identifying information or icon images. • Reads the selected image SOP instance from the CD-R media and displays it on the monitor[...]

  • Page 9

    No. MIIXR0002EAC 2.3.2 Operation 2.3.2.1 Transfer of X-ray Examination  The operation for manual transfer of X-ray examination is described below: STEP-1: Select the images or the patient to be transferred. STEP-2: Request transfer. STEP-3: Insert the blank CD-R media. STEP-4: Request recording the transferred images onto the CD-R media. 2.3.2.2[...]

  • Page 10

    No. MIIXR0002EAC 3 AE Sp ecifications 3.1 DICOM Recording Specification The DICOM Recording AE provides Standard Conformance to the DICOM Media Storage Service, File Format Class and t he Media Storage Application Profile. Table 1 A pplication Profile Identifier Real World Activ ity Role SC Option Basic Cardiac X-ray Angiographic Studies on CD-R Me[...]

  • Page 11

    No. MIIXR0002EAC 3.2.1 File Meta Information for the Application Entity The Application Entity Title is not relev ant because this DICOM Reader AE only reads CD-R media. 3.2.2 Real-World Activity 3.2.2.1 Real-World Activity - Review of X-ray Examination DICOM Reader AE acts as a FSR when chosen by the operator. This AE reads the DICOMDIR from the C[...]

  • Page 12

    No. MIIXR0002EAC 5 Extensions, S pecializations, and Privatizations of SOP Classes and T ransfer Synt axes Not applicable to this product. 6 Configuration For the Digital Fluorography System, the configuration can be set. Note: Settings and changes are performed by Tosh iba Service Personnel at the time of installation of the Digital Fluorography S[...]

  • Page 13

    No. MIIXR0002EAC 8 X-Ray Angiographic Information Object Definition 8.1 Entity Module Definitions The information modules for the X-Ray Angiographic devices are defined below. 8.1.1 Media Storage Directory IOD Modules Table 5 Object Module / key Reference Usage 1 DICOM File Meta Information 8.2.1 M File-set Identificat ion Module 8.3.1 M Basic Dire[...]

  • Page 14

    No. MIIXR0002EAC 8.1.3 XA IOD Modules Table 7 Information Entity Module Reference Usage 1 Patient Patient Module 8.5.1 M Study General Study Module 8.5.2 M Study Patient Study Module 8.5.3 U Series General Series Module 8.5.4 M Equipment General Equi pment Module 8.5.5 M Image General Image Module 8.5.6 M Image Image Pixel Module 8.5.7 M Image Cont[...]

  • Page 15

    No. MIIXR0002EAC 8.2 DICOM File Meta Information 8.2.1 DICOM File Meta Information of Directory IOD Table 8 Attribute Name Tag Type Attribute Description File Preamble No Tag 1 Alw ays set DICOM Prefix No Tag 1 Alway s set ("DICM") Group Length (0002, 0000) 1 Always set File Meta Information Version ( 0002, 0001) 1 Alway s set (0x0001) Me[...]

  • Page 16

    No. MIIXR0002EAC 8.3.2 Directory Information Module Table 11 Attribute Name Tag Type Attribute Description Offset of the First Directory Record of the Root Directory Entity (0004, 1200) 1 Always set Offset of the Last Directory Record of the Root Directory Entity (0004, 1202) 1 Always set File-set Consistency Flag (0004, 1212) 1 Always set Director[...]

  • Page 17

    No. MIIXR0002EAC 8.4.2 STUDY keys Table 13 Attribute Name Tag T ype Attribute Description Study Date (0008, 0020) 1 Alway s set Study Time (0008, 0030) 1 Always set Study Description (0008, 1030) 2 Length=0 when no entry is made Study Instance UID (0020, 000D) 1C Alway s set Study ID (0020, 0010) 1 Always set Accession Number (0008, 0050) 2 Length=[...]

  • Page 18

    No. MIIXR0002EAC 8.4.4 IMAGE keys Table 15 Attribute Name Tag Type A ttribute Description Instance Number (0020, 0013) 1 Alway s set Image Type (0008, 0008) 1 Alway s set Image Date (0008, 0023) 3 Alway s set Image Time (0008, 0033) 3 Alway s set Positioner Primary Angle (0018, 1510) 3 Alway s set [degree] Positioner Secondary Angle (0018, 1511) 3 [...]

  • Page 19

    No. MIIXR0002EAC 8.5 XA Information Object Definisions 8.5.1 Patient Module Table 16 Attribute Name Tag Type Attribute Description Patient's Name (0010, 0010) 2 Always set except for urgent patient Patient ID (0010, 0020) 2 Always set Patient's Birth Date (0010, 0030) 2 Length=0 when no entry is made Patient's Sex (0010, 0040) 2 Alwa[...]

  • Page 20

    No. MIIXR0002EAC 8.5.4 General Series Module Table 19 Attribute Name Tag Type Attribute Description Modality (0008, 0060) 1 Always set ("XA") Series Instance UID (0020, 000E) 1 Alway s set Series Number (0020, 0011) 2 Always set Series Date (0008, 0021) 3 Always set Series Time (0008, 0031) 3 Always set Performing Physician's Name (0[...]

  • Page 21

    No. MIIXR0002EAC 8.5.7 Image Pixel Module Table 22 Attribute Name Tag Type Attribute Description Samples per Pixel (0028, 0002) 1 Always set (0x0001) Photometric Interpretation (0028, 0004) 1 Always set ("MONOCHROME2") Rows (0028, 0010) 1 Always set (0x0400 or 0x0200) Columns (0028, 0011) 1 Always set (0x0400 or 0x0200) Bits Allocated (00[...]

  • Page 22

    No. MIIXR0002EAC 8.5.11 X-ray Image Module Table 26 Attribute Name Tag Type Attribute Description Frame Increment Pointer (0028, 0009) 1C Always set (0x00181063) Image Type (0008, 0008) 1 Alw ays set Pixel Intensity Relationship (0028, 1040) 1 Alway s set ("DISP" or "LIN") Samples per Pixel (0028, 0002) 1 Always set (0x0001) Pho[...]

  • Page 23

    No. MIIXR0002EAC 8.5.13 XA Positioner Module Table 28 Attribute Name Tag Type Attribute Description Distance Source to Detector (0018, 1110) 3 Always set [mm] Estimated Radiographic Magnification Factor (0018,1114) 3 Alway s set Positioner Motion (0018, 1500) 2C Always set ("STATIC") Positioner Primary Angle (0018, 1510) 2 Always set [deg[...]