Go to page of
Similar user manuals
-
Heat Pump
Trane 2TWB-SVU01A-EN
6 pages 0.26 mb -
Heat Pump
Trane 4TWA3
8 pages 1.31 mb -
Heat Pump
Trane GEV
90 pages 5.03 mb -
Heat Pump
Trane 22-5202-03-3605
8 pages 1.04 mb -
Heat Pump
Trane GETB
32 pages 1.12 mb -
Heat Pump
Trane 18-BC55D1-2
8 pages 1.31 mb -
Heat Pump
Trane WCY060G1
20 pages 1.17 mb -
Heat Pump
Trane GEH
90 pages 5.03 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Trane 4YCY4060A, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Trane 4YCY4060A one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Trane 4YCY4060A. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Trane 4YCY4060A should contain:
- informations concerning technical data of Trane 4YCY4060A
- name of the manufacturer and a year of construction of the Trane 4YCY4060A item
- rules of operation, control and maintenance of the Trane 4YCY4060A item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Trane 4YCY4060A alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Trane 4YCY4060A, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Trane service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Trane 4YCY4060A.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Trane 4YCY4060A item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
© 2008 Trane Pub. No. 22-1797-03 Product Data 4YCY4024A through 4YCY4060A Single Packaged Convertible Gas/Electric 14 SEER 2 - 5 Ton, 40 - 120 KBTU R-410A 22-1797-03[...]
-
Page 2
2 It's Hard to Stop a Trane. Single Packaged Convertible Gas/Electric System Trane offers a complete family of packaged gas/electric heating and cooling sys- tems, designed to give you the unbeatable combination of energy efficiency and lower operating costs. In warm weather, the packaged gas/electric system functions as an all-electric, high [...]
-
Page 3
3 Contents Optional Equipment Listing 4 General Data 5 Performance Data Cooling 9 Indoor Fan 11 Typical Wiring 15 Optional Equipment 18 Dimensional Data 23 Mechanical Specifications 29[...]
-
Page 4
4 Optional Equipment Listing OPTIONAL EQUIPMENT FOR PACKAGED UNITS (check mark [ ✓ ✓ ✓ ✓ ✓ ] indicates accessories included) Hinged Filter Access Door (4YCY4024-036) 8 ................................................................ BA Y ACCDOR1A[ ] Hinged Filter Access Door (4YCY4042-060) 8 ...............................................[...]
-
Page 5
5 MODEL RA TED Volts/PH/Hz Performance Cooling BTUH j Indoor Airflow (CFM) Power Input (KW) EER/SEER(BTU/Watt-Hr .) n Sound Power Rating [dB(A)] 8 Performance Heating k Input BTUH - 1st Stage (Natural Gas) p Input BTUH - 2nd Stage (Natural Gas) p AFUE T emp. Rise — Min/Max ( ° F) Orifice Qty / Drill Size (Natural Gas) l POWER CONN.—V/PH/HZ Min[...]
-
Page 6
6 General Data MODEL RA TED Volts/PH/Hz Performance Cooling BTUH j Indoor Airflow (CFM) Power Input (KW) EER/SEER(BTU/Watt-Hr .) n Sound Power Rating [dB(A)] 8 Performance Heating k Input BTUH - 1st Stage (Natural Gas) p Input BTUH - 2nd Stage (Natural Gas) p AFUE T emp. Rise — Min/Max ( ° F) Orifice Qty / Drill Size (Natural Gas) l POWER CONN.?[...]
-
Page 7
7 General Data 1 1 1 1 1 Certified in accordance with the Unitary Air-Conditioner Equipment certification program, which is based on ARI Standard 210/240. Noise calculated in accordance with A.R.I. Standard 270. 2 2 2 2 2 All models are U L Listed. Ratings shown are for elevations up to 2000 ft. For higher elevations reduce ratings at a rate of 4% [...]
-
Page 8
8 General Data MODEL RA TED Volts/PH/Hz Performance Cooling BTUH j Indoor Airflow (CFM) Power Input (KW) EER/SEER(BTU/Watt-Hr .) n Sound Power Rating [dB(A)] 8 Performance Heating k Input BTUH - 1st Stage (Natural Gas) p Input BTUH - 2nd Stage (Natural Gas) p AFUE T emp. Rise — Min/Max ( ° F) Orifice Qty / Drill Size (Natural Gas) l POWER CONN.?[...]
-
Page 9
9 Performance Data Cooling 4YCY4036A1/3 A T 1200 NOM CFM (COOLING PERFORMANCE A T INDOOR DRY BULB TEMPERA TURES) OD ID TO T SENS CA P A T ENTERING DB TEMP TO T AL AMB WB CAP 72 75 78 80 KW 85 59 34.5 28.8 32.4 34.5 34.5 2.7 63 36.0 23.4 27.0 30.5 32.9 2.7 67 38.8 18.5 22.0 25.6 27.9 2.8 71 41.9 13.5 17.1 20.6 23.0 2.8 95 59 32.0 27.6 31.2 32.0 32.0[...]
-
Page 10
10 Performance Data Cooling 4YCY4048A1/3 A T 1600 NOM CFM (COOLING PERFORMANCE A T INDOOR DRY BULB TEMPERA TURES) OD ID TO T SENS CA P A T ENTERING DB TEMP TO T AL AMB WB CA P 72 75 78 80 KW 85 59 45.3 38.2 42.9 45.3 45.3 3.6 63 47.2 31.0 35.7 40.5 43.7 3.6 67 50.9 24.4 29.1 33.9 37.1 3.7 71 55.0 17.7 22.5 27.3 30.4 3.7 95 59 42.7 37.0 41.7 42.7 42[...]
-
Page 11
11 Indoor Blower Performance Indoor Fan Performance 4YCY4024A Down Airflow Horizontal Airflow 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 Watts 52 66 89 115 140 164 186 206 229 259 300 CFM 706 716 727 733 731 719 700 679 662 659 682 Watts - 94 120 148 177 207 233 254 267 290 320 CFM - 793 805 813 813 806 793 780 778 799 800 Watts - - 125 153 182 211 24[...]
-
Page 12
12 Indoor Blower Performance Indoor Fan Performance 4YCY4042A Down Airflow Horizontal Airflow 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 Watts 162 173 197 226 256 285 313 343 383 440 525 CFM 1058 1062 1063 1063 1062 1060 1057 1053 1048 1042 1033 Watts 179 230 265 296 329 366 403 431 450 485 555 CFM 1179 1196 1204 1206 1205 1203 1199 1194 1185 1169 114[...]
-
Page 13
13 Indoor Fan Performance 4YCY4060A Down Airflow Horizontal Airflow 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 Watts 200 220 250 285 320 354 386 417 449 487 538 CFM 1407 1394 1396 1403 1408 1408 1402 1391 1380 1377 1392 Watts 268 316 354 386 417 448 483 520 559 597 630 CFM 1584 1608 1616 1615 1608 1600 1593 1586 1579 1568 1550 Watts 378 430 478 522 56[...]
-
Page 14
14 Heating Airflow, horizontal or downflow from .2 to .6” wg. Selection Low Stage High Stage 7-OFF 8-OFF A 600 850 7-ON 8-OFF B 625 900 7-OFF 8-ON C 650 925 7-ON 8-ON D 700 975 4YCY4024A1064 Switch Settings Nominal Airflow Selection Low Stage High Stage 7-OFF 8-OFF A 725 1000 7-ON 8-OFF B 775 1075 7-OFF 8-ON C 850 1150 7-ON 8-ON D 925 1250 4YCY40[...]
-
Page 15
15 Typical Field Wiring C 757192i2 B G Y W1 W2 R COMMON FA N COMPRESSOR HEA T FIRST ST AGE HEA T SECOND ST AGE 24V UNIT CONTROL BO X GROUND WIRE 3 PH POWER UNIT NO TE 1 1 PH POWER B G Y W1 W2 R COMMON FA N COMPRESSOR HEA T FIRST ST AGE HEA T SECOND ST AGE 24V B G Y W1 W2 R (GR) (WH) (WH) (GR) (WH) (WH) (GR) (WH) (WH)[...]
-
Page 16
16 Typical Wiring[...]
-
Page 17
17 From Dwg. 21D757165 P02 Typical Wiring[...]
-
Page 18
18 Optional Equipment BA YCURB050A Full Perimeter Roof Mounting Curb for *****018-036A 46 3/8 17 7/8 3 3 5/8 19 1/2 2 3/16 19 1/2 14 1 1/2 38 7/8 15 35 7/8 43 3/8 The drawings on this page are prepared by the manufacturer in order to provide detail regarding job layout only. These drawings are not intended to be used as a basis to construct, build [...]
-
Page 19
19 Optional Equipment BA YCURB051A Full Perimeter Roof Mounting Curb for *****042-060A 56 1/8 15 7/8 3 10 7/8 19 1/2 4 3/4 19 1/2 14 41 7/8 20 1 1/2 38 7/8 53 1/8 The drawings on this page are prepared by the manufacturer in order to provide detail regarding job layout only. These drawings are not intended to be used as a basis to construct, build [...]
-
Page 20
20 Optional Equipment The drawings on this page are prepared by the manufacturer in order to provide detail regarding job layout only. These drawings are not intended to be used as a basis to construct, build or modify the items depicted in the drawings. The manufacturer is no t responsible for the unauthorized use of these drawings and expressly d[...]
-
Page 21
21 BA YECON101,102A Down Discharge Economizer and Rain Hood (Mounts Over Horizontal Return Air Opening) BA YECON200,201A Horizontal Economizer and Rain Hood Return Duct Roofcurb Relief damper Mist eliminator Economizer rain hood HV AC Unit Outside air dampers Return air dampers Required filter kit, order separately A Optional Equipment The drawings[...]
-
Page 22
22 A B C D FULL Y OPEN 2/3 1/3 FULL Y CLOSED BA YDMPR101,102A, 25% Motorized Outside Air Damper (Mounts Over Horizontal Return AIr Opening) BA YOSAH001,002A, 25% Outside Air Damper (Replaces Filter/Coil Access Panel) Optional Equipment The drawings on this page are prepared by the manufacturer in order to provide detail regarding job layout only. T[...]
-
Page 23
23 Dimensional Data 4YCY4024A through 4YCY4036A (1 of 3)[...]
-
Page 24
24 Dimensional Data 4YCY4024A through 4YCY4036A (2 of 3)[...]
-
Page 25
25 4YCY4024A through 4YCY4036A (3 of 3) Dimensional Data[...]
-
Page 26
26 Dimensional Data 4YCY4042A through 4YCY4060A (1 of 3)[...]
-
Page 27
27 Dimensional Data 4YCY4042A through 4YCY4060A (2 of 3)[...]
-
Page 28
28 4YCY4042A through 4YCY4060A (3 of 3) Dimensional Data[...]
-
Page 29
29 Mechanical Specifications General All units shall be factory assembled, piped, internally wired and fully charged with refrigerant. All units shall be designed to operate at outdoor ambient temperatures as high as 1 15°F. Cooling capacities shall be rated in accordance with A.R.I. standards. The 4YCY4 heating/cooling unit design is UL listed, s[...]