Go to page of
Similar user manuals
-
Air Conditioner
Trane 060E
12 pages 1.12 mb -
Air Conditioner
Trane PKG-PRC007-EN
52 pages 0.88 mb -
Air Conditioner
Trane 4TTX5024A1
20 pages 1.6 mb -
Air Conditioner
Trane XL
6 pages 0.36 mb -
Air Conditioner
Trane XL Series
6 pages 0.27 mb -
Air Conditioner
Trane LO
136 pages 1.63 mb -
Air Conditioner
Trane TRG-TRC003-EN
53 pages 0.83 mb -
Air Conditioner
Trane 2TTX4
6 pages 0.72 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Trane GAF2A0A30S21SA, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Trane GAF2A0A30S21SA one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Trane GAF2A0A30S21SA. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Trane GAF2A0A30S21SA should contain:
- informations concerning technical data of Trane GAF2A0A30S21SA
- name of the manufacturer and a year of construction of the Trane GAF2A0A30S21SA item
- rules of operation, control and maintenance of the Trane GAF2A0A30S21SA item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Trane GAF2A0A30S21SA alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Trane GAF2A0A30S21SA, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Trane service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Trane GAF2A0A30S21SA.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Trane GAF2A0A30S21SA item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
Modular Multi-position Air Handler s PUB. NO . 22-1858-02 Air Handler - Con ver tible Model: Series 2 Air Handlers 1.5 - 3 ton GAF2A0A18S11SA GAF2A0A24S21SA GAF2A0A30S21SA GAF2A0A36S31SA[...]
-
Page 2
2 Pub . No. 22-1858-02 Featur es and Benefits © 2011 T rane • Unique Cabinet Design - Double Wall F oamed and F or med Cabinet System - W ater Proof Cabinet Design - R-4.2 Insulating V alue (A vg. Insulating V alue R-8) - Composite F oamed Cabinet Doors - Sweat Eliminating Cabinet Design - Loose Fiber Eliminating Cabinet Design - Smooth Clea[...]
-
Page 3
Pub . No . 22-1858-02 3 Contents Features and Benefits 2 Optional Equipment 4 Unique Cabinet Design Features and Benefits 5 General Data 6 GAF2A0A18S11SA 6 GAF2A0A24S21SA 6 GAF2A0A30S21SA 6 GAF2A0A36S31SA 6 P erformance Data 7 Electrical Data 11 Wiring Diagrams 13 Field Wiring 14 Con ver tibility 16 Dimensions 17[...]
-
Page 4
4 Pub . No. 22-1858-02 Optional Equipment OPTIONAL EQUIPMENT FOR GAF2 AIR HANDLERS Accessory Number Description Fits Cabinet Size BA YECAA05LG1A Electric Heater , 5kW , Lugs, 24V Control, 1 Ph A BA YECAA08LG1A Electric Heater , 8kW , Lugs, 24V Control, 1 Ph A BA YECAA10LG1A Electric Heater , 10kW , Lugs, 24V Control, 1 Ph A BA YSFSCABAA Supply Duct[...]
-
Page 5
Pub . No . 22-1858-02 5 Unique Cabinet Design Featur es and Benefits 5 Conduit Connection Location r Integrated Horizontal Drain P ans e Compact 20.8” Depth with Doors Remo ved 1 Unique Cabinet Design 2 Precision Durable Door Seals q Thermal Expansion V alve (TXV) 3 Refrigeration Connections 9 All Aluminum Coil 4 Condensate Connections w Maximum[...]
-
Page 6
6 Pub . No. 22-1858-02 General Data PRODUCT SPECIFICA TIONS MODEL RA TED V OL TS/PH/HZ. RA TINGS 1 INDOOR COIL — T ype Rows — F .P .I. F ace Area (sq. ft.) T ube Size (in.) Refrigerant Control Drain Conn. Size (in.) 2 DUCT CONNECTIONS INDOOR F AN — T ype Diameter-Width (In.) No . Used Drive - No . Speeds CFM vs. in. w .g. No . Motors — H.P [...]
-
Page 7
Pub . No . 22-1858-02 7 General Data GAF2A0A18 AIRFLO W PERFORMANCE T ABLE AIRFLO W PERFORMANCE GAF2A0A18S11SA EXTERNAL ST A TIC (in w .g) AIRFLO W (CFM) Speed T aps - 230 V OL TS Speed T aps - 208 V OL TS 3 2 † 1 3 2 † 1 0 952 768 710 940 654 598 0.1 894 741 687 885 636 581 0.2 845 704 658 831 610 558 0.3 785 662 620 775 577 526 0.4 724 607 56[...]
-
Page 8
8 Pub . No. 22-1858-02 Per for mance Data GAF2A0A24 AIRFLO W PERFORMANCE T ABLE AIRFLO W PERFORMANCE GAF2A0A24S21SA EXTERNAL ST A TIC (in w .g) AIRFLO W (CFM) Speed T aps - 230 V OL TS Speed T aps - 208 V OL TS 3 2 † 1 3 2 † 1 0 998 848 771 899 737 658 0.1 949 816 745 868 710 630 0.2 911 784 711 834 683 602 0.3 869 750 679 794 650 567 0.4 825 7[...]
-
Page 9
Pub . No . 22-1858-02 9 Per for mance Data GAF2A0A30 AIRFLO W PERFORMANCE T ABLE AIRFLO W PERFORMANCE GAF2A0A30S21SA EXTERNAL ST A TIC (in w .g) Speed T aps - 230 V OL TS Speed T aps - 208 V OL TS 3 2 † 1 3 2 1 0 1052 967 932 1024 877 826 0.1 1012 929 898 980 846 800 0.2 963 888 861 934 814 771 0.3 914 849 823 885 777 738 0.4 865 805 784 837 739 [...]
-
Page 10
10 Pub . No . 22-1858-02 AIRFLO W PERFORMANCE GAF2A0A36S31SA EXTERNAL ST A TIC (in w .g) Speed T aps - 230 V OL TS Speed T aps - 208 V OL TS 3 2 † 1 3 2 1 0 1191 1146 1094 1040 1015 964 0.1 1180 1132 1085 1033 1004 959 0.2 1158 1110 1065 1014 984 942 0.3 1119 1082 1035 979 958 916 0.4 1079 1045 1003 942 923 887 0.5 1040 1005 969 907 886 857 0.6 9[...]
-
Page 11
Pub . No . 22-1858-02 11 Electrical Data WIRING D A T A GAF2A0A18S11SA Heater Model No. No. of Circuits 240 V OL T 208 V OL T Capacity Heater Amps per Circuit Minimum Circuit Ampacity Maximum Overload Protection Capacity Heater Amps per Circuit Minimum Circuit Ampacity Maximum Overload Protection kW BTUH kW BTUH No Heater - - - 2.0** 3 15 - - 2.0**[...]
-
Page 12
12 Pub . No . 22-1858-02 Electrical Data DIST ANCE FROM BELL Y B AND TO SHAFT F A CE OF MO T OR FOR MINIMUM VIBRA TION WHEEL BLO WER HOUSING BELL Y BAND M OTO R A A is determined per char t Wheel is centered in Blower Housing WIRING D A T A GAF2A0A36S31SA Heater Model No. No. of Circuits 240 V OL T 208 V OL T Capacity Heater Amps per Circuit Minimu[...]
-
Page 13
Pub . No . 22-1858-02 13 WIRING DIA GRAM FOR GAF2A0A18S, GAF2A0A24S, GAF2A0A30S, AND GAF2A0A36S AIR HANDLERS[...]
-
Page 14
14 Pub . No . 22-1858-02 Field Wiring GAF2 AIR HANDLERS WITH SINGLE SPEED COOLING Air Handler Hook-up Diagra m Cooling Red Y ellow Green White Blue Y ellow Green White Blue B B - Blue Blue W G Y Y - Y ellow Y ellow R Red O Orange Comfort Control Air Handler Air Conditioner Field wiring Red Blue Green W1 White[...]
-
Page 15
Pub . No . 22-1858-02 15 Field Wiring GAF2 AIR HANDLERS WITH SINGLE SPEED HEA T PUMP Air Handler Hook-up Diagra m HP Red Y ellow Green White Blue Orange Y ellow Green White Blue B B - Blue R - Red W G Y Y - Y ellow R Red O Orange Comfort Control Air Handler Field wiring Y ellow Blue Black (X2) Red Orange Heat Pump Red Blue Green W1 White[...]
-
Page 16
16 Pub . No . 22-1858-02 GAF2 Conver tibility Multi-position Air Handler Airflow Airflow Horizontal Left* Horizontal Right* Horizontal Left Condensate Drains Refrigerant Connections Horizontal Right Condensate Drains Refrigerant Connections * Note: No internal modifications required for any position. 1 Badge rotation will keep brand in correct posi[...]
-
Page 17
Pub . No . 22-1858-02 17 H W D Dimensions GAF2 AIR HANDLER DIMENSIONAL D A T A GAF2 AIR HANDLERS ARE ALL ONE PIECE CABINETS. Model Number H x D x W in. Unit Net W eight lbs. GAF2A0A18S11SA 39 x 22 x 17.5 107 GAF2A0A24S21SA 39 x 22 x 17.5 110 GAF2A0A30S21SA 39 x 22 x 17.5 111 GAF2A0A36S31SA 39 x 22 x 17.5 112[...]
-
Page 18
18 Pub . No . 22-1858-02 GAF2 OUTLINE DRA WING[...]
-
Page 19
Pub . No . 22-1858-02 19[...]
-
Page 20
T rane 6200 T roup Highway T yler , TX 75707 www .trane .com 11/11 The manuf acturer has a policy of continuous product and product data improvement and it reserves the right to change design and specifications without notice.[...]